Dynamic imaging of penetration and decontamination after chemical eye burn using optical coherence tomography

被引:0
作者
Spoeler, Felix [1 ]
Foerst, Michael [1 ]
Kurz, Heinrich [1 ]
Frentz, Markus [2 ]
Schrage, Norbert F. [2 ]
机构
[1] Rhein Westfal TH Aachen, Inst Semicond Elect, Sommerfeldstr 24, D-52074 Aachen, Germany
[2] Aachen Ctr Technol Transfer Ophthalmol, D-52070 Aachen, Germany
来源
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES III | 2007年 / 6627卷
关键词
optical coherence tomography; medical imaging; chemical burn; cornea;
D O I
10.1117/12.727820
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For chemical burns a considerable lack of methods exists for defining penetration kinetics and effects of decontamination within biological structures. We demonstrate that time-resolved high-resolution optical coherence tomography can close this gap by monitoring changes in scattering properties and thicknesses of rabbit cornea ex vivo after topical application of different corrosives. Modifications in the corneal microstructure due to direct chemical interaction or changes in the hydration state as a result of osmotic imbalance compromise the corneal transparency. The associated increase in light scattering intensity within the cornea is observed with high spatial and temporal resolution. Parameters affecting the severity of pathophysiological damage like diffusion velocity, depth of penetration, resistance of barriers, and effectiveness of emergency treatment procedures are obtained. This study demonstrates the potential of high-resolution OCT for the visualization and direct non-invasive measurement of specific interaction of chemicals with the eye, exemplified on hydrofluoric acid burn.
引用
收藏
页数:7
相关论文
共 16 条
  • [1] Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry
    Drexler, W
    Hitzenberger, CK
    Baumgartner, A
    Findl, O
    Sattmann, H
    Fercher, AF
    [J]. EXPERIMENTAL EYE RESEARCH, 1998, 66 (01) : 25 - 33
  • [2] Ultrahigh-resolution optical coherence tomography
    Drexler, W
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 47 - 74
  • [3] Depth-resolved monitoring of glucose diffusion in tissues by using optical coherence tomography
    Ghosn, Mohamad G.
    Tuchin, Valery V.
    Larin, Kirill V.
    [J]. OPTICS LETTERS, 2006, 31 (15) : 2314 - 2316
  • [4] GRIEVE K, 2004, INVEST OPHTHALMOL VI, V45
  • [5] HOSSEINI K, 2004, INVEST OPHTHALMOL VI, V45
  • [6] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [7] Izatt JA, 1994, ARCH OPHTHALMOL, V112
  • [8] MCCULLEY JP, 1990, T AM OPHTHALMOL SOC, V88
  • [9] PFISTER RR, 1996, INVEST OPHTHALMOL VI, V37
  • [10] In vitro measurement of rabbit corneal epithelial thickness using ultrahigh resolution optical coherence tomography
    Reiser, BJ
    Ignacio, TS
    Wang, YM
    Taban, M
    Graff, JM
    Sweet, P
    Chen, ZP
    Chuck, RS
    [J]. VETERINARY OPHTHALMOLOGY, 2005, 8 (02) : 85 - 88