Experimental and simulation analysis of daylight glare probability in offices with dynamic window shades

被引:138
作者
Konstantzos, Iason [1 ,2 ]
Tzempelikos, Athanasios [1 ,2 ]
Chan, Ying-Chieh [1 ,2 ]
机构
[1] Purdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Mech Engn, Ray W Herrick Labs, W Lafayette, IN 47907 USA
关键词
Daylight glare; Visual comfort; Shading control; Facades; DISCOMFORT GLARE; VISUAL COMFORT; CONTROL STRATEGIES; LUMINANCE; VIEW; ILLUMINANCE; METRICS;
D O I
10.1016/j.buildenv.2015.02.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental and simulation study to evaluate daylight glare probability (DGP) in office spaces with roller shades. Roller shades can be controlled in various ways and have an openness, transmitting direct and diffuse light even when fully closed. Since DGP combines the overall brightness of the visual field and the perceived contrast of the scene in one metric, the development of glare protection guidelines is complex in this case. Full-scale experiments with an HDR camera in test offices were combined with a validated, integrated daylighting and glare model. Correlations between DGP and design parameters (work plane or vertical illuminance) were developed and the applicability of DGP and DGPs for closed and controlled shades is discussed. The results show that DGPs is not an accurate metric when the sun is within the field of view even for low openness fabrics while the DGP equation might need a correction for such cases, due to extreme values of the solar corona's luminance influencing the luminance term. DGP and work plane illuminance are not well correlated, except for the case of perfectly diffuse fabrics. However, for all instances when the sun is not visible by the occupant, DGPs can be used to approximate daylight glare, including cases with sunlight on various surfaces in the space, for any fabric openness and control type. This enables the development of model-based, real-time glare control shading operation, with vertical illuminance being the basic parameter. Simple sunlight protection strategies cannot prevent glare, despite maximizing daylight utilization. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:244 / 254
页数:11
相关论文
共 50 条
[1]  
[Anonymous], 2012, LM8312 IESNA
[2]  
Araji M.T., 2008, Architectural Science Review, V51, P252, DOI [10.3763/asre.2008.5130, DOI 10.3763/ASRE.2008.5130]
[3]   Windows, view, and office characteristics predict physical and psychological discomfort [J].
Aries, Myriam B. C. ;
Veitch, Jennifer A. ;
Newsham, Guy R. .
JOURNAL OF ENVIRONMENTAL PSYCHOLOGY, 2010, 30 (04) :533-541
[4]   Visual discomfort and glare rating assessment of integrated daylighting and electric lighting systems using HDR imaging techniques [J].
Borisuit, Apiparn ;
Scartezzini, Jean-Louis ;
Thanachareonkit, Anothai .
ARCHITECTURAL SCIENCE REVIEW, 2010, 53 (04) :359-373
[5]   High dynamic range photogrammetry for synchronous luminance and geometry measurement [J].
Cai, H. .
LIGHTING RESEARCH & TECHNOLOGY, 2013, 45 (02) :230-257
[6]   Visual comfort assessment of smart photovoltachromic windows [J].
Cannavale, Alessandro ;
Fiorito, Francesco ;
Resta, Debora ;
Gigli, Giuseppe .
ENERGY AND BUILDINGS, 2013, 65 :137-145
[7]   Daylighting metrics based on illuminance, distribution, glare and directivity [J].
Cantin, F. ;
Dubois, M-C .
LIGHTING RESEARCH & TECHNOLOGY, 2011, 43 (03) :291-307
[8]   A systematic method for selecting roller shade properties for glare protection [J].
Chan, Ying-Chieh ;
Tzempelikos, Athanasios ;
Konstantzos, Iason .
ENERGY AND BUILDINGS, 2015, 92 :81-94
[9]   Efficient venetian blind control strategies considering daylight utilization and glare protection [J].
Chan, Ying-Chieh ;
Tzempelikos, Athanasios .
SOLAR ENERGY, 2013, 98 :241-254
[10]   A hybrid ray-tracing and radiosity method for calculating radiation transport and illuminance distribution in spaces with venetian blinds [J].
Chan, Ying-Chieh ;
Tzempelikos, Athanasios .
SOLAR ENERGY, 2012, 86 (11) :3109-3124