Microfluidic paper-based analytical device by using Pt nanoparticles as highly active peroxidase mimic for simultaneous detection of glucose and uric acid with use of a smartphone

被引:46
|
作者
Zheng, Jie [1 ]
Zhu, Min [2 ]
Kong, Jiao [1 ]
Li, Zimu [1 ]
Jiang, Jianming [1 ]
Xi, Yachao [1 ]
Li, Fang [1 ]
机构
[1] Hefei Univ Technol, Sch Chem & Chem Engn, Anhui Prov Key Lab Adv Catalyt Mat & React Engn, Hefei 230009, Anhui, Peoples R China
[2] PLA Army Acad Artillery & Air Def, Hefei 230031, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
mu PAD; Pt NPs; Glucose; Uric acid; Smartphone; COLORIMETRIC ASSAY;
D O I
10.1016/j.talanta.2021.122954
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, a simple microfluidic paper-based analytical device (mu PAD) by using platinum nanoparticles (Pt NPs) as highly active peroxidase mimic for simultaneous determination of glucose and uric acid was fabricated. The mu PAD consisted of one sample transportation layer, four paper-based detection chips, and two layers of hydrophobic polyethylene terephthalate (PET) films. The four detection chips were immobilized with various chromogenic reagents, Pt NPs, and specific oxidase (glucose oxidase or uricase). H2O2 generated by specific enzymatic reactions could oxidize co-immobilized chromogenic reagents to produce colored products by using Pt NPs as efficient catalyst. The multi-layered structure of mu PAD could effectively improve the color uniformity and color intensity. Total color intensity from each two detection chips modified with distinct chromogenic reagents were used for quantitative analysis of glucose and uric acid, respectively, resulting in significantly improved sensitivity. The linear range for glucose and uric acid detection was 0.01-5.0 mM and 0.01-2.5 mM, respectively. Satisfied results were obtained for glucose and uric acid detection in real serum samples. An easy-to-use smartphone APP was developed for convenient and intelligent detection. The developed mu PAD integrated with smartphone as detector holds great applicability for simple and portable on-site analysis.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Fabrication of a microfluidic paper-based analytical device by silanization of filter cellulose using a paper mask for glucose assay
    Cai, Longfei
    Wang, Yong
    Wu, Yunying
    Xu, Chunxiu
    Zhong, Minghua
    Lai, Heyun
    Huang, Junsheng
    ANALYST, 2014, 139 (18) : 4593 - 4598
  • [22] Inkjet printed microfluidic paper-based analytical device (μPAD) for glucose colorimetric detection in artificial urine
    Han Zhang
    Ethan Smith
    Wei Zhang
    Anhong Zhou
    Biomedical Microdevices, 2019, 21
  • [23] Inkjet printed microfluidic paper-based analytical device (PAD) for glucose colorimetric detection in artificial urine
    Zhang, Han
    Smith, Ethan
    Zhang, Wei
    Zhou, Anhong
    BIOMEDICAL MICRODEVICES, 2019, 21 (03)
  • [24] A smartphone-integrated ready-to-use paper-based sensor with mesoporous carbon-dispersed Pd nanoparticles as a highly active peroxidase mimic for H2O2 detection
    Zhang, Wenchi
    Niu, Xiangheng
    Li, Xin
    He, Yanfang
    Song, Hongwei
    Peng, Yinxian
    Pan, Jianming
    Qiu, Fengxian
    Zhao, Hongli
    Lan, Minbo
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 412 - 420
  • [25] Simultaneous determination of renal function biomarkers in urine using a validated paper-based microfluidic analytical device
    Rossini, Eduardo Luiz
    Milani, Maria Izabel
    Carrilho, Emanuel
    Pezza, Leonardo
    Pezza, Helena Redigolo
    ANALYTICA CHIMICA ACTA, 2018, 997 : 16 - 23
  • [26] Chemometrics-assisted microfluidic paper-based analytical device for the determination of uric acid by silver nanoparticle plasmon resonance
    Hamedpour, Vahid
    Postma, Geert J.
    van den Heuvel, Edwin
    Jansen, Jeroen J.
    Suzuki, Koji
    Citterio, Daniel
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (09) : 2305 - 2313
  • [27] Chemometrics-assisted microfluidic paper-based analytical device for the determination of uric acid by silver nanoparticle plasmon resonance
    Vahid Hamedpour
    Geert J. Postma
    Edwin van den Heuvel
    Jeroen J. Jansen
    Koji Suzuki
    Daniel Citterio
    Analytical and Bioanalytical Chemistry, 2018, 410 : 2305 - 2313
  • [28] Simultaneous colorimetric detection of metallic salts contained in low explosives residue using a microfluidic paper-based analytical device (μPAD)
    Chabaud, Kathryn R.
    Thomas, Jennifer L.
    Torres, Michelle N.
    Oliveira, Sheila
    McCord, Bruce R.
    FORENSIC CHEMISTRY, 2018, 9 : 35 - 41
  • [29] Smartphone-Based Colorimetric Microfluidic Paper-Based Analytical Device for On-Site Detection of Calcium Ions in Milk Samples
    Ajayi, David Taiwo
    Teepoo, Siriwan
    ANALYTICAL LETTERS, 2025, 58 (03) : 465 - 480
  • [30] An environmentally friendly microfluidic paper-based analytical device for simultaneous colorimetric detection of nitrite and nitrate in food products
    Thongkam, Thinikan
    Hemavibool, Khuanjit
    MICROCHEMICAL JOURNAL, 2020, 159