Two-tone intensity-modulated optical stimulus for self-referencing microwave characterization of high-speed photodetectors

被引:19
作者
Wang, Heng [1 ]
Zhang, Shangjian [1 ,2 ]
Zou, Xinhai [1 ]
Zhang, Yali [1 ]
Lu, Rongguo [1 ]
Zhang, Zhiyao [1 ,2 ]
Zhang, Xiaoxia [1 ]
Liu, Yong [1 ,2 ]
机构
[1] Univ Elect Sci & Technol China, Sch Optoelect Informat, State Key Lab Elect Thin Films & Integrated Devic, Chengdu 610054, Peoples R China
[2] Univ Elect Sci & Technol China, Collaborat Innovat Ctr Elect Mat & Devices, Chengdu 610054, Peoples R China
基金
中国国家自然科学基金;
关键词
Frequency response; Photodetectors; Two-tone modulation; Microwave photonics; FREQUENCY-RESPONSE MEASUREMENTS; CALIBRATION; NOISE;
D O I
10.1016/j.optcom.2015.08.028
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The two-tone intensity modulated optical stimulus is proposed and demonstrated for measuring the high-frequency response of photodetectors. The method provides a narrow linewidth and wide bandwidth optical stimulus based on the two-tone modulation of a Mach-Zehnder electro-optical intensity modulator, and achieves the self-referenced measurement of photodetectors without the need for correcting the power variation of optical stimulus. Moreover, the two-tone intensity modulation method allows bias-independent measurement with doubled measuring frequency range. In the experiment, the consistency between our method and the conventional methods verifies the simple but accurate measurement. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 113
页数:4
相关论文
共 22 条
[1]  
[Anonymous], 2012, AUST ROBOT AUTOM ASS, DOI DOI 10.1007/978-3-319-16199-0_32
[2]   HIGH-FREQUENCY PHOTODIODE CHARACTERIZATION USING A FILTERED INTENSITY NOISE TECHNIQUE [J].
BANEY, DM ;
SORIN, WV ;
NEWTON, SA .
IEEE PHOTONICS TECHNOLOGY LETTERS, 1994, 6 (10) :1258-1260
[3]   Microwave photonics combines two worlds [J].
Capmany, Jose ;
Novak, Dalma .
NATURE PHOTONICS, 2007, 1 (06) :319-330
[4]   Calibration of sampling oscilloscopes with high-speed photodiodes [J].
Clement, Tracy S. ;
Hale, Paul D. ;
Williams, Dylan F. ;
Wang, C. M. ;
Dienstfrey, Andrew ;
Keenan, Darryl A. .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2006, 54 (08) :3173-3181
[5]   High-accuracy photoreceiver frequency response measurements at 1.55 μm by use of a heterodyne phase-locked loop [J].
Dennis, Tasshi ;
Hale, Paul D. .
OPTICS EXPRESS, 2011, 19 (21) :20103-20114
[6]   WIDE-BANDWIDTH RECEIVER PHOTODETECTOR FREQUENCY-RESPONSE MEASUREMENTS USING AMPLIFIED SPONTANEOUS EMISSION FROM A SEMICONDUCTOR OPTICAL AMPLIFIER [J].
EICHEN, E ;
SCHLAFER, J ;
RIDEOUT, W ;
MCCABE, J .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1990, 8 (06) :912-915
[7]   Vector calibration of optical reference receivers using a frequency-domain method [J].
Humphreys, DA ;
Harper, MR ;
Smith, AJA ;
Smith, IM .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (02) :894-897
[8]   Optoelectronic frequency response measurement of photodiodes by using high-extinction ratio optical modulator [J].
Inagakia, Keizo ;
Kawanishi, Tetsuya ;
Izutsu, Masayuki .
IEICE ELECTRONICS EXPRESS, 2012, 9 (04) :220-226
[9]   Measuring the Photodetector Frequency Response for Ultrasonic Applications by a Heterodyne System With Difference-Frequency Servo Control [J].
Koch, Christian .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (05) :1169-1174
[10]   WIDEBAND CALIBRATION OF PHOTODETECTOR FREQUENCY RESPONSE BASED ON OPTICAL HETERODYNE MEASUREMENT [J].
Miao, Ang ;
Huang, Yongqing ;
Huang, Hui ;
Wang, Rui ;
Wang, Song ;
Ren, Xiaomin .
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2009, 51 (01) :44-48