Reducing cooling tower fill fouling and degradation with water quality control

被引:0
作者
Olson, Vickie G.
机构
来源
Proceedings of the ASME Power Conference 2007 | 2007年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Cooling tower fill may be composed of wood or plastic, but it must provide adequate surface area for heat dissipation. Online and field water quality analysis can maximize tower efficiency and minimize maintenance. Uncontrolled levels of pH, bio-growth, or over-application of chemicals cause degradation of the material and plugging. Automatic control of pH conditioner can be accomplished with proven differential pH methods tied to analog and/or digital control. Oxidizing biocide application can be optimized with ORP and halogen analysis and control. Overuse of this type of biocide can also cause wood delignification that can affect the structural integrity of the tower. Another cause of fouling is excessive solids accumulation. Solids buildup can be minimized with side-stream filtration and/or clarification and monitored with low maintenance self-cleaning optical probes.
引用
收藏
页码:785 / 789
页数:5
相关论文
共 50 条
  • [41] Modeling oscillatory fouling in enhanced tubes in cooling tower systems
    Wu, Jie
    Zhang, Zhengjiang
    Cheng, Lin
    Li, Wei
    Xu, Zhiming
    HEAT AND MASS TRANSFER, 2011, 47 (05) : 563 - 569
  • [42] WATER COOLING TOWER PLUMES
    BAKER, KG
    CHEMICAL AND PROCESS ENGINEERING, 1967, 48 (01): : 56 - &
  • [43] SALT WATER COOLING TOWER
    NESTER, DM
    CHEMICAL ENGINEERING PROGRESS, 1971, 67 (07) : 49 - &
  • [44] Legionella Regulation, Cooling Tower Positivity and Water Quality in the Quebec Context
    Racine, Patrick
    Elliott, Steve
    Betts, Stephen
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 1, 2019, 125 : 350 - 359
  • [45] FREE COOLING BY COOLING-TOWER WATER
    GOSWAMI, D
    REVELIOTTY, CN
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1987, 29 (01): : 32 - 37
  • [46] Modeling oscillatory fouling in enhanced tubes in cooling tower systems
    Jie Wu
    Zhengjiang Zhang
    Lin Cheng
    Wei Li
    Zhiming Xu
    Heat and Mass Transfer, 2011, 47 : 563 - 569
  • [47] AUTOMATIC COOLING TOWER CONTROL
    FEITLER, H
    TOWNSEND, CR
    CHEMICAL ENGINEERING PROGRESS, 1969, 65 (05) : 63 - &
  • [48] CONTROL COOLING TOWER BLOWDOWN
    MAPSTONE, GE
    HYDROCARBON PROCESSING, 1967, 46 (01): : 155 - &
  • [49] BIOLOGICAL FOULING IN INDUSTRIAL COOLING WATER-SYSTEMS AND ITS CONTROL
    RAMAKRISHNA, C
    DESAI, JD
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 1991, 50 (01): : 30 - 42
  • [50] LEACHING OF ASBESTOS-CEMENT COOLING-TOWER FILL.
    Anon
    Electric Power Research Institute, Coal Combustion Systems Division, (Report) EPRI CS, 1981, (1777):