Reducing cooling tower fill fouling and degradation with water quality control

被引:0
|
作者
Olson, Vickie G.
机构
来源
Proceedings of the ASME Power Conference 2007 | 2007年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Cooling tower fill may be composed of wood or plastic, but it must provide adequate surface area for heat dissipation. Online and field water quality analysis can maximize tower efficiency and minimize maintenance. Uncontrolled levels of pH, bio-growth, or over-application of chemicals cause degradation of the material and plugging. Automatic control of pH conditioner can be accomplished with proven differential pH methods tied to analog and/or digital control. Oxidizing biocide application can be optimized with ORP and halogen analysis and control. Overuse of this type of biocide can also cause wood delignification that can affect the structural integrity of the tower. Another cause of fouling is excessive solids accumulation. Solids buildup can be minimized with side-stream filtration and/or clarification and monitored with low maintenance self-cleaning optical probes.
引用
收藏
页码:785 / 789
页数:5
相关论文
共 50 条
  • [1] Cooling tower fill fouling control in a geothermal power plant
    Yu, FP
    Ginn, LD
    McCoy, WF
    CORROSION REVIEWS, 1999, 17 (3-4): : 205 - 217
  • [2] A survey of cooling tower water quality for condenser tube fouling potential
    Zdaniuk, G. J.
    Chamra, L. M.
    Mago, P. J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2008, 222 (A1) : 111 - 122
  • [3] Cooling tower fill faceoff
    Beyer, A
    CHEMICAL PROCESSING, 1999, 62 (12): : 32 - +
  • [4] NUMERICAL ANALYSIS OF COOLING TOWER WATER FOULING IN ENHANCED TUBES
    Fu, Ping
    Li, Hong-Xia
    Li, Wei
    Du, Yi-Lin
    Xiao, Sheng-Lan
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 4, 2014,
  • [5] Fouling of cooling tower film fill: Causes, cleanup techniques and operating guidelines to minimize reoccurrence
    Robinette, DJ
    Puckorius, PR
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 58, PTS I AND II, 1996, 58 : 495 - 500
  • [6] Cooling tower fill: the neglected moneymaker
    Burger, R
    HYDROCARBON PROCESSING, 2000, 79 (07): : 65 - 68
  • [7] Selecting the Optimal Cooling Tower Fill
    Puckorius, Paul R.
    CHEMICAL ENGINEERING PROGRESS, 2013, 109 (08) : 31 - 34
  • [8] EFFECT OF SURFACE TEMPERATURE ON FOULING OF COOLING-TOWER WATER.
    Epstein, Norman
    Heat Transfer Engineering, 1987, 8 (01) : 60 - 62
  • [9] CORROSION AND FOULING CONTROL IN COOLING WATER SYSTEMS
    CHAKRABO.S
    ALLARD, B
    KEMISK TIDSKRIFT, 1974, 86 (10): : 52 - &
  • [10] Effect of fill layout and water flow rate distribution on the performance for cooling tower
    Wang M.
    Wang J.
    Zhang C.
    Wang, Jin (14115313@bjtu.edu.cn), 2018, Harbin Institute of Technology (50): : 124 - 131