Capillary electrophoresis-inductively coupled plasma-mass spectrometry: A report on technical principles and problem solutions, potential, and limitations of this technology as well as on examples of application

被引:74
作者
Michalke, B [1 ]
机构
[1] GSF, Natl Res Ctr Environm & Hlth, Inst Ecol Chem, D-85764 Neuherberg, Germany
关键词
as speciation; capillary electrophoresis-inductively coupled plasma-mass spectrometry; Mt characterization; review; Se speciation;
D O I
10.1002/elps.200410314
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper summarizes some basic principles of capillary electrophoresis (CE), inductively coupled plasma-mass spectrometry (ICP-MS), and coupling of both devices. Especially the interfacing is described in detail. A special focus is drawn to various interface developments reported in literature and technical problems, i.e., requirements to the interface setup and respective solutions. Nowadays, typically sheath flow-based interfaces are used. The sheath flow fulfills two requirements of hyphenation, (i) the closing of the electrical circuit of CE and (ii) the feeding of the used nebulizer with an adequate flow rate. In the beginning of CE-ICP-MS coupling predominantly home-made interface-nebulizer constructions were developed and tested for various speciation problems. Now increasingly such laboratory-constructed interfaces are left. Mostly commercial nebulizers are employed being combined with commercially available tee or cross fittings to connect the CE capillary to the electrode, the additional sheath flow, and the nebulizer. Due to the low sample amounts and low flow rates from CE, such nebulizers are typically low-flow nebulizers like, e.g., the microconcentric nebulizer (MCN) and the direct injection nebulizer (DIN). However, there are also reports on couplings using standard Meinhard systems. Still the control and reduction of a siphoning sucting flow and sufficient detection limits are the major problems in hyphenating CE to ICP-MS. Different solutions are reported on these problems and summarized here. Finally numerous applications are reported. Mostly, applications are performed on speciation of selenium, arsenic, metallothionein isoforms, mercury, or cobalt.
引用
收藏
页码:1584 / 1597
页数:14
相关论文
共 78 条
[51]   Determination of element species at trace levels using capillary electrophoresis-inductively coupled plasma sector field mass spectrometry [J].
Prange, A ;
Schaumlöffel, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1329-1332
[52]  
PRANGE A, 2000, METAL IONS BIOL MED, V6, P430
[53]   Plasma-source mass spectrometry for speciation analysis: state-of-the-art [J].
Ray, SJ ;
Andrade, F ;
Gamez, G ;
McClenathan, D ;
Rogers, D ;
Schilling, G ;
Wetzel, W ;
Hieftje, GM .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1050 (01) :3-34
[54]   Roxarsone and transformation products in chicken manure: Determination by capillary electrophoresis-inductively coupled plasma-mass spectrometry [J].
Rosal, CG ;
Momplaisir, GM ;
Heithmar, EM .
ELECTROPHORESIS, 2005, 26 (7-8) :1606-1614
[55]   A new interface for combining capillary electrophoresis with inductively coupled plasma-mass spectrometry [J].
Schaumlöffel, D ;
Prange, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05) :452-456
[56]  
SCHLEGEL D, 1998, 51999 UFZ
[57]   Determination of neodymium-fulvic acid binding constants by capillary electrophoresis inductively coupled plasma mass spectrometry (CE-ICP-MS) [J].
Sonke, JE ;
Salters, VJM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (02) :235-240
[58]   Dispersion effects of laminar flow and spray chamber volume in capillary electrophoresis-inductively coupled plasma-mass spectrometry: a numerical and experimental approach [J].
Sonke, JE ;
Furbish, DJ ;
Salters, VJM .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :205-218
[59]   Investigation of Cr(III) hydrolytic polymerisation products by capillary electrophoresis-inductively coupled plasma-mass spectrometry [J].
Stewart, II ;
Olesik, JW .
JOURNAL OF CHROMATOGRAPHY A, 2000, 872 (1-2) :227-246
[60]   Inductively coupled plasma mass spectrometric detection for chromatography and capillary electrophoresis [J].
Sutton, K ;
Sutton, RMC ;
Caruso, JA .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :85-126