Capillary electrophoresis-inductively coupled plasma-mass spectrometry: A report on technical principles and problem solutions, potential, and limitations of this technology as well as on examples of application

被引:74
作者
Michalke, B [1 ]
机构
[1] GSF, Natl Res Ctr Environm & Hlth, Inst Ecol Chem, D-85764 Neuherberg, Germany
关键词
as speciation; capillary electrophoresis-inductively coupled plasma-mass spectrometry; Mt characterization; review; Se speciation;
D O I
10.1002/elps.200410314
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper summarizes some basic principles of capillary electrophoresis (CE), inductively coupled plasma-mass spectrometry (ICP-MS), and coupling of both devices. Especially the interfacing is described in detail. A special focus is drawn to various interface developments reported in literature and technical problems, i.e., requirements to the interface setup and respective solutions. Nowadays, typically sheath flow-based interfaces are used. The sheath flow fulfills two requirements of hyphenation, (i) the closing of the electrical circuit of CE and (ii) the feeding of the used nebulizer with an adequate flow rate. In the beginning of CE-ICP-MS coupling predominantly home-made interface-nebulizer constructions were developed and tested for various speciation problems. Now increasingly such laboratory-constructed interfaces are left. Mostly commercial nebulizers are employed being combined with commercially available tee or cross fittings to connect the CE capillary to the electrode, the additional sheath flow, and the nebulizer. Due to the low sample amounts and low flow rates from CE, such nebulizers are typically low-flow nebulizers like, e.g., the microconcentric nebulizer (MCN) and the direct injection nebulizer (DIN). However, there are also reports on couplings using standard Meinhard systems. Still the control and reduction of a siphoning sucting flow and sufficient detection limits are the major problems in hyphenating CE to ICP-MS. Different solutions are reported on these problems and summarized here. Finally numerous applications are reported. Mostly, applications are performed on speciation of selenium, arsenic, metallothionein isoforms, mercury, or cobalt.
引用
收藏
页码:1584 / 1597
页数:14
相关论文
共 78 条
[1]   Metallothionein isoforms separation and cadmium speciation by capillary electrophoresis with ultraviolet and quadrupole-inductively coupled plasma mass spectrometric detection [J].
Alvarez-Llamas, G ;
de la Campa, MRF ;
Sanz-Medel, A .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :105-119
[2]   Determination of cobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry [J].
Baker, SA ;
Miller-Ihli, NJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (12) :1823-1832
[3]   Capillary electrophoresis and inductively coupled plasma spectrometry: Status report [J].
Barnes, RM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :246-251
[4]  
BARNES RM, 1991, ACS SYM SER, V445, P158
[5]   Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation [J].
Bendahl, L ;
Gammelgaard, B ;
Jons, O ;
Farver, O ;
Hansen, SH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) :38-42
[6]  
BENDAHL L, 2004, J ANAL ATOM SPECTROM, V19, P493
[7]   NEW APPROACH TO THE ANALYSIS OF LOW-LEVELS OF ANIONS IN WATER [J].
BONDOUX, G ;
JANDIK, P ;
JONES, WR .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :79-88
[8]  
*BUCH ZEIT VERL GM, 1980, FORM PHYS CHEM MATH
[9]   Optimization of the hyphenation between capillary zone electrophoresis and inductively coupled plasma mass spectrometry for the measurement of As-, Sb-, Se- and Te-species, applicable to soil extracts [J].
Casiot, C ;
Donard, OFX ;
Potin-Gautier, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (01) :173-187
[10]   Rapid simultaneous multielemental speciation by capillary electrophoresis coupled to inductively coupled plasma time-of-flight mass spectrometry [J].
Costa-Fernández, JM ;
Bings, NH ;
Leach, AM ;
Hieftje, GM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) :1063-1067