Signal processing method for flight time measurement of gas ultrasonic flowmeter

被引:0
|
作者
Zheng, Dandan [1 ]
Mei, Jianqiang [2 ]
Mao, Yang [1 ]
Yang, Zhibin [1 ]
机构
[1] Tianjin Univ, Sch Elect & Informat Engn, Tianjin, Peoples R China
[2] Tianjin Univ Technol & Educ, Sch Elect Engn, Tianjin, Peoples R China
来源
2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021) | 2021年
基金
中国国家自然科学基金;
关键词
time of flight; gas ultrasonic flowmeter; double-threshold method; THRESHOLD;
D O I
10.1109/I2MTC50364.2021.9459938
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Gas ultrasonic flowmeters are widely applied in industry because of high accuracy. The time of flight (TOF) measurement is significant which determines the flowmeter performance. The traditional TOF method are easily influenced by unstable flow and noise that leads to bad results especially in large velocities. In this paper, a new signal processing method based on the double-threshold method is proposed. The peak's characteristics of the received signal are used to find the feature point on the received signal, and then using this feature point and the zero-crossing detection to complete the calculation of TOF. By comparing the new method with other traditional method based on flow experiments, higher precision and reliability are obtained. And the calibration test results show that the flowmeter can achieve 1% measurement error in the wide flowrate range from 1m/s to 35m/s.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A new method for processing ultrasonic gas flowmeter signal in wet gas
    Wang, Mi
    Zheng, Dandan
    Mei, Jianqiang
    Mao, Yang
    Hu, Jiayu
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2021, 15 (01) : 2 - 13
  • [2] Signal processing method of ultrasonic gas flowmeter based on transit-time mathematical characteristics
    Zhou, Junyang
    Wang, Peng
    Wang, Ruibing
    Niu, Zhenyu
    Zhang, Kai
    MEASUREMENT, 2025, 239
  • [3] Design of ultrasonic flowmeter for wet gas measurement
    Zheng, Dandan
    Zhai, Mengxu
    Wang, Mi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (08)
  • [4] Applications of digital signal processing methods in TOF calculation of ultrasonic gas flowmeter
    Ma, Jie
    Xu, Ke-Jun
    Jiang, Zhen
    Zhang, Lun
    Xu, Hao-Ran
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 79
  • [5] Transmitting pulse signal design for ultrasonic time of flight measurement in short baseline framework
    Zhao, Shen
    Wang, Yueke
    Qiao, Chunjie
    Zhou, Chao
    SIXTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2013, 8916
  • [6] A method to avoid the cycle-skip phenomenon in time-of-flight determination for ultrasonic flow measurement
    Liu, Cheng-wei
    Fang, Ze-hua
    Hu, Liang
    Liu, Yong-qiang
    Su, Rui
    Liu, Wei-ting
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2021, 22 (09): : 695 - 706
  • [7] Design and implementation of AGC in gas ultrasonic flowmeter
    Liu Yanping
    Liu Xin
    Nan Jing
    Yang Jia
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL I, 2007, : 534 - 537
  • [8] A novel time-of-flight difference determination method for ultrasonic thickness measurement with ultrasonic echo onset point detection
    Liu, Wangyu
    Li, Dongxun
    Xie, Weigui
    APPLIED ACOUSTICS, 2025, 233
  • [9] Digital signal processing techniques for accurate ultrasonic sensor measurement
    Andria, G
    Attivissimo, F
    Giaquinto, N
    MEASUREMENT, 2001, 30 (02) : 105 - 114
  • [10] Method for acquiring time of flight from high aliasing signal in heat exchange fouling ultrasonic testing
    Li, Xia
    Sun, Lingfang
    Li, Jing
    Piao, Heng
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2021, 43 (11) : 2438 - 2449