Validation of Peek Acuity application in pediatric screening programs in Paraguay

被引:16
作者
de Venecia, Bryce [1 ]
Bradfield, Yasmin [1 ]
Trane, Ralph Moller [1 ]
Bareiro, Alicia [2 ]
Scalamogna, Miguel [2 ]
机构
[1] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Madison, WI 53792 USA
[2] Fdn Vis, Cazal Dept, Calle Ingavi & Coronel, San Lorenzo 2300, Paraguay
关键词
pediatric ophthalmology; validation study; screening; mobile phone application; AMBLYOPIA RISK-FACTORS; SPOT VISION SCREENER; REFRACTIVE ERROR; CHILDREN; IMPAIRMENT; COST;
D O I
10.18240/ijo.2018.08.21
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To validate the Peek Acuity mobile phone application in pediatric populations and compare its utility, both economic and diagnostic, against conventional screening methods using a pediatric ophthalmologist examination as the gold standard. METHODS: A cohort of 393 subjects from Fernando de la Mora, Paraguay (ages 6-16y) were enrolled in the study. Subjects were randomly assigned a starting screening modality among: Peek Acuity, a single line of tumbling E optotypes set at 20/40, and Spot Vision Screener. Once completing the first screening modality, the subjects completed the two remaining techniques. Referral criteria were established based on the most current American Association of Pediatric Ophthalmology and Strabismus (AAPOS) recommendations: 20/40 for Peek Acuity and the tumbling E, and refractive error detection for the Spot Vision Screener. Subjects that failed to achieve the cutoff for any of the three screening techniques or subjects that passed the screening but were randomly selected to perform a comprehensive eye exam to determine the false negative rate, were evaluated by a pediatric ophthalmologist. This evaluation was considered the gold standard, and included vision assessment by a Snellen chart, strabismus evaluation, and cycloplegic refraction with dilated fundoscopy. RESULTS: We obtained 48% sensitivity, 83% specificity, 43% positive predictive value, and 86% negative predictive value for Peek Acuity's ability to refer compared to evaluation by a pediatric ophthalmologist, failing to achieve a desired sensitivity for implementation. Peek Acuity trended to overestimate the subject's visual acuity, providing a higher visual acuity that would not indicate referral for a comprehensive eye examination. However, its high specificity accurately predicted a significant number of children who did not need further evaluation. When comparing the three screening methods, no single screening modality outperformed the others. Peek Acuity represented a technology that was economically feasible compared to other screening modalities in low income settings, due to the prevalence of cell phone use. CONCLUSION: Peek Acuity represents an efficient tool that has potential for implementation in school screenings with different strategies aimed at pediatric populations due to its low cost and high specificity. An increase in sensitivity would improve detection of children with refractive errors.
引用
收藏
页码:1384 / 1389
页数:6
相关论文
共 22 条
  • [1] American Association for Pediatric Ophthalmology and Strabismus, 2011, STAT STAT SCREEN REQ
  • [2] Evaluation of the Spot Vision Screener in young children in Costa Rica
    Arana Mendez, Maricela
    Arguello, Leslie
    Martinez, Joaquin
    Salas Vargas, Marisela
    Alvarado Rodriguez, Ana Maria
    Papa, Carrie E.
    Peterseim, Carolyn M.
    Otarola Viquez, Mauricio
    Trivedi, Rupal H.
    Peterseim, Mae Millicent W.
    [J]. JOURNAL OF AAPOS, 2015, 19 (05): : 441 - 444
  • [3] Vision and the Achievement Gap Among Urban Minority Youth
    Basch, Charles E.
    [J]. JOURNAL OF SCHOOL HEALTH, 2011, 81 (10) : 599 - 605
  • [4] Development and Validation of a Smartphone-Based Visual Acuity Test (Peek Acuity) for Clinical Practice and Community-Based Fieldwork
    Bastawrous, Andrew
    Rono, Hillary K.
    Livingstone, Iain A. T.
    Weiss, Helen A.
    Jordan, Stewart
    Kuper, Hannah
    Burton, Matthew J.
    [J]. JAMA OPHTHALMOLOGY, 2015, 133 (08) : 930 - 937
  • [5] Empirical Studies on Usability of mHealth Apps: A Systematic Literature Review
    Cruz Zapata, Belen
    Luis Fernandez-Aleman, Jose
    Idri, Ali
    Toval, Ambrosio
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2015, 39 (02) : 1 - 19
  • [6] Mobile Phone Tools for Field-Based Health care Workers in Low-Income Countries
    DeRenzi, Brian
    Borriello, Gaetano
    Jackson, Jonathan
    Kumar, Vikram S.
    Parikh, Tapan S.
    Mph, Pushwaz VirkMd
    Lesh, Neal
    [J]. MOUNT SINAI JOURNAL OF MEDICINE, 2011, 78 (03): : 406 - 418
  • [7] Guidelines for automated preschool vision screening: A 10-year, evidence-based update
    Donahue, Sean P.
    Arthur, Brian
    Neely, Daniel E.
    Arnold, Robert W.
    Silbert, David
    Ruben, James B.
    [J]. JOURNAL OF AAPOS, 2013, 17 (01): : 4 - 8
  • [8] Influence of uncorrected refractive error and unmet refractive error on visual impairment in a Brazilian population
    Ferraz, Fabio H.
    Corrente, Jose E.
    Opromolla, Paula
    Schellini, Silvana A.
    [J]. BMC OPHTHALMOLOGY, 2014, 14
  • [9] Screening for refractive error and fitting with spectacles in rural and urban India: Cost-effectiveness
    Frick, Kevin D.
    Riva-Clement, Liliana
    Shankar, Manjunath B.
    [J]. OPHTHALMIC EPIDEMIOLOGY, 2009, 16 (06) : 378 - 387
  • [10] Global cost of correcting vision impairment from uncorrected refractive error
    Fricke, T. R.
    Holden, B. A.
    Wilson, D. A.
    Schlenther, G.
    Naidoo, K. S.
    Resnikoff, S.
    Frick, K. D.
    [J]. BULLETIN OF THE WORLD HEALTH ORGANIZATION, 2012, 90 (10) : 728 - 738