Off-axis dose response characteristics of an amorphous silicon electronic portal imaging device

被引:34
|
作者
Greer, Peter B. [1 ]
机构
[1] Calvary Mater Newcastle Hosp, Newcastle, NSW, Australia
[2] Univ Newcastle, Newcastle, NSW 2308, Australia
关键词
amorphous silicon; dose verification; EPID;
D O I
10.1118/1.2779944
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) have typically been calibrated to dose at central axis (CAX). Division of acquired images by the flood-field (FF) image that corrects for pixel sensitivity variation as well as open field energy-dependent off-axis response variation should result in a flat EPID response over the entire matrix for the same field size. While the beam profile can be reintroduced to the image by an additional correction matrix, the CAX EPID response to dose calibration factor is assumed to apply to all pixels in the detector. The aim of this work was to investigate the dose response of the Varian aS500 amorphous silicon detector across the entire detector area. First it was established that the EPID response across the panel becarne stable (within similar to 0.2%) for MU settings greater than similar to 200 MU. The EPID was then FF calibrated with a high MU setting of similar to 400 for all subsequent experiments. Whole detector images with varying MU settings from 2-500 were then acquired for two dose rates (300 and 600 MU/min) for 6 MV photons for two EPIDs. The FF corrected EPID response was approximately flat or uniform across the detector for greater than 100 MU delivered (within 0.5%). However, the off-axis EPID response was greater than the CAX response for small MU irradiations, giving a raised EPID profile. Up to 5% increase in response at 20 cm off-axis compared to CAX was found for very small MU settings for one EPID, while it was within 2% for the second (newer) EPID. Off-axis response nonuniformities attributed to detector damage were also found for the older EPID. Similar results were obtained with the EPID at 18 MV energy and operating in asynchronous mode (acquisition not synchronized with beam pulses), however the profiles were flatter and more irregular for the small MU irradiations. By moving the detector laterally and repeating the experiments, the increase in response off-axis was found to depend on the pixel position relative to the beam CAX. When the beam was heavily filtered by a phantom the off-axis response variation was reduced markedly to within 0.5% for all MU settings. Independent measurements of off-axis point doses with ion chamber did not show any change in off-axis factor with MUs. Measurements of beam quality (TMR20-10) for MU settings of 2, 5, and 100 at central axis and at 15 cm off-axis could not explain the effect. The response change is unlikely to be significant for clinical IMRT verification with this imaging/acclerator system where MUs are of the order of 100-300, provided the detector does not exhibit radiation damage artifacts. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3815 / 3824
页数:10
相关论文
共 50 条
  • [1] Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry
    Greer, PB
    MEDICAL PHYSICS, 2005, 32 (12) : 3558 - 3568
  • [2] Dosimetric characteristics and day-to-day performance of an amorphous-silicon type electronic portal imaging device
    Chang, Chiou-Shiung
    Tseng, Yi-Han
    Hwang, Jing-Min
    Shih, Rompin
    Chuang, Keh-Shih
    RADIATION MEASUREMENTS, 2016, 91 : 9 - 14
  • [3] A two-dimensional matrix correction for off-axis portal dose prediction errors
    Bailey, Daniel W.
    Kumaraswamy, Lalith
    Bakhtiari, Mohammad
    Podgorsak, Matthew B.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [4] Dose response characteristics of a novel CCD camera-based electronic portal imaging device comparison with OCTAVIUS detector
    Anvari, Akbar
    Aghamiri, Seyed Mahmoud Reza
    Mahdavi, Seyed Rabie
    Alaei, Parham
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2015, 11 (04) : 765 - 769
  • [5] Monte Carlo computation of dosimetric amorphous silicon electronic portal images
    Siebers, JV
    Kim, JO
    Ko, L
    Keall, PJ
    Mohan, R
    MEDICAL PHYSICS, 2004, 31 (07) : 2135 - 2146
  • [6] Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy
    Greer, PB
    Popescu, CC
    MEDICAL PHYSICS, 2003, 30 (07) : 1618 - 1627
  • [7] An effective correction algorithm for off-axis portal dosimetry errors
    Bailey, Daniel W.
    Kumaraswamy, Lalith
    Podgorsak, Matthew B.
    MEDICAL PHYSICS, 2009, 36 (09) : 4089 - 4094
  • [8] Calculation of exit dose for conformal and dynamically-wedged fields, based on water-equivalent path length measured with an amorphous silicon electronic portal imaging device
    Kavuma, Awusi
    Glegg, Martin
    Metwaly, Mohamed
    Currie, Garry
    Elliott, Alex
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (03): : 44 - 60
  • [9] Dose verifications by use of liquid ionization chamber of an electronic portal imaging device (EPID).
    Tateoka K.
    Oouchi A.
    Nakata K.
    Hareyama M.
    Radiological Physics and Technology, 2008, 1 (2) : 171 - 177
  • [10] Evaluation of rapid dose map acquisition of a scanning liquid-filled ionization chamber electronic portal imaging device
    Chang, JW
    Mageras, GS
    Ling, CC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05): : 1432 - 1445