Predictors of Electrical Storm in Patients With Idiopathic Dilated Cardiomyopathy - How to Stratify the Risk of Electrical Storm

被引:17
|
作者
Takigawa, Masateru [1 ]
Noda, Takashi [1 ]
Kurita, Takashi [1 ]
Aihara, Naohiko [1 ]
Yamada, Yuko [1 ]
Okamura, Hideo [1 ]
Satomi, Kazuhiro [1 ]
Suyama, Kazuhiro [1 ]
Shimizu, Wataru [1 ]
Kamakura, Shiro [1 ]
机构
[1] Natl Cardiovasc Ctr, Dept Internal Med, Div Cardiol, Suita, Osaka 5658565, Japan
关键词
Dilated cardiomyopathy; Electrical storm; Implantable cardioverter defibrillator; Signal averaged electrocardiogram; Ventricular tachyarrhythmias; SIGNAL-AVERAGED ELECTROCARDIOGRAM; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; NONISCHEMIC CONGESTIVE CARDIOMYOPATHY; NONSUSTAINED VENTRICULAR-TACHYCARDIA; CARDIAC-RESYNCHRONIZATION-THERAPY; BUNDLE-BRANCH BLOCK; ATRIAL-FIBRILLATION; LATE POTENTIALS; HEART-FAILURE; APPROPRIATE SHOCKS;
D O I
10.1253/circj.CJ-10-0092
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Electrical storm (ES) is a serious problem in patients with an implantable cardioverter defibrillator (ICD). However, insufficient reports have indicated the predictors of ES in ICD patients with idiopathic dilated cardiomyopathy (DCM) The purpose of this study was to clarify the predictors of ES for risk stratification in DCM patients with an ICD Methods and Results: Of 446 ICD patients, 53 DCM patients were included in this study During a mean follow-up of 55 +/- 36 months. ES (>= 3 times appropriate ICD therapy within 24h) occurred in 18/53 (34%) patients According to multivariate Cox proportional hazard regression analysis, a duratidn of the terminal low amplitude signals of <40 mu V (LAS40) (HR 1 4/10 ms increase, 95% confidence interval (CI) 1 1-2 1, P=0 0049) or root mean square voltage of the last 40 ms of the QRS complex (RMS40) (HR 088/1 mu V, 95%CI 0 77-0 96, P=0 001) on the signal averaged electrocardiogram, and a history of atrial fibrillation (AF) before ICD implantation (HR 2 3, 95%CI 1 2-5.0, P=0 013) were independently associated with an increased risk of ES Conclusions: Our data indicated that a longer LAS40, lower RMS40 and history of AF before ICD implantation could strongly predict ES. and the combination of those parameters could effectively stratify the risk of ES in DCM patients (Circ J 2010, 74: 1822-1829)
引用
收藏
页码:1822 / 1829
页数:8
相关论文
共 50 条
  • [21] Prognostic impact of recurrences in patients with electrical storm
    Mueller, Julian
    Behnes, Michael
    Ellguth, Dominik
    Schupp, Tobias
    Mashayekhi, Kambis
    Borggrefe, Martin
    Akin, Ibrahim
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2019, 53 (02) : 71 - 76
  • [22] How Electrical Storms Recur Over Time in Patients With Implantable Cardioverter Defibrillators - Subanalysis of the Nippon Storm Study -
    Yasuoka, Ryobun
    Maruyama, Masahiro
    Nakazawa, Gaku
    Noda, Takashi
    Nitta, Takashi
    Aizawa, Yoshifusa
    Ohe, Tohru
    Kurita, Takashi
    CIRCULATION JOURNAL, 2025, 89 (02) : 214 - 223
  • [23] Electrical storm: A clinical and electrophysiological overview
    Conti, Sergio
    Pala, Salvatore
    Biagioli, Viviana
    Del Giorno, Giuseppe
    Zucchetti, Martina
    Russo, Eleonora
    Marino, Vittoria
    Dello Russo, Antonio
    Casella, Michela
    Pizzamiglio, Francesca
    Catto, Valentina
    Tondo, Claudio
    Carbucicchio, Corrado
    WORLD JOURNAL OF CARDIOLOGY, 2015, 7 (09): : 555 - 561
  • [24] Prevalence, predictors, and mortality significance of the causative arrhythmia in patients with electrical storm
    Verma, A
    Kilicaslan, F
    Marrouche, NF
    Minor, S
    Khan, M
    Wazni, O
    Burkhardt, JD
    Belden, WA
    Cummings, JE
    Abdul-Karim, A
    Saliba, W
    Schweikert, RA
    Tchou, PJ
    Martin, DO
    Natale, A
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (11) : 1265 - 1270
  • [25] Dana cement of ventricular electrical storm: a contemporary appraisal
    Kowlgi, Gurukripa N.
    Cha, Yong-Mei
    EUROPACE, 2020, 22 (12): : 1768 - 1780
  • [26] Impact of Different Pharmacotherapies on Long-Term Outcomes in Patients with Electrical Storm
    Schupp, Tobias
    Behnes, Michael
    Ellguth, Dominik
    Mueller, Julian
    Reiser, Linda
    Bollow, Armin
    Taton, Gabriel
    Reichelt, Thomas
    Engelke, Niko
    Kim, Seung-hyun
    Nienaber, Christoph
    Akin, Muharrem
    Mashayekhi, Kambis
    Bertsch, Thomas
    Borggrefe, Martin
    Akin, Ibrahim
    PHARMACOLOGY, 2019, 103 (3-4) : 179 - 188
  • [27] Catheter ablation of electrical storm in patients with structural heart disease
    Kozeluhova, Marketa
    Peichl, Petr
    Cihak, Robert
    Wichterle, Dan
    Vancura, Vlastimil
    Bytesnik, Jan
    Kautzner, Josef
    EUROPACE, 2011, 13 (01): : 109 - 113
  • [28] Risk factors and prognostic role of an electrical storm in patients after myocardial infarction with an implanted ICD for secondary prevention
    Kwasniewski, Wojciech
    Filipecki, Artur
    Orszulak, Michal
    Orszulak, Witold
    Urbanczyk, Dagmara
    Roczniok, Robert
    Trusz-Gluza, Maria
    Mizia-Stec, Katarzyna
    ARCHIVES OF MEDICAL SCIENCE, 2018, 14 (03) : 500 - 509
  • [29] Electrical storm in a patient with Duchenne muscular dystrophy cardiomyopathy triggered by abrupt -blocker interruption
    Fragakis, Nikolaos
    Sotiriadou, Melani
    Krexi, Lydia
    Vassilikos, Vassilios
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2017, 22 (06)
  • [30] Electrical storm: Prognosis and management
    Elsokkari, Ihab
    Sapp, John L.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2021, 66 : 70 - 79