Development of high-performance liquid chromatography-electrospray mass spectrometry with size-exclusion chromatography for determination of acrylamide in fried foods

被引:5
|
作者
Inoue, K [1 ]
Yoshimura, Y [1 ]
Nakazawa, H [1 ]
机构
[1] Hoshi Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Shinagawa Ku, Tokyo 1428501, Japan
关键词
acrylamide; liquid chromatography mass spectrometry; size-exclusion chromatography; fried food;
D O I
10.1081/JLC-120021756
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method by liquid chromatography-electrospray mass spectrometry (LC/MS) with a size-exclusion chromatography column for the analysis of acrylamide in fried foods, is reported. In the mass spectral analysis using an electrospray MS, the signal at m/z 72, which was assigned to the [M+H](+) ion, was observed as the main peak. The main m/z signal showed a maximum at the firagmentor voltage of 100 V The retention time for the elution of acrylamide from the size-exclusion chromatography column ranged from 15 to 20 min, and the eluate was analyzed by LC/MS with a reversed-phase column. A linear response was found for the acrylamide standard tested within the concentration range of 5.0-1000 ng/mL, with correlation coefficients (r) greater than 0.99. Sample preparation was performed by means of solvent extraction, which gave acrylamide recoveries higher than 90% with relative standard deviations less than 10%, with C-13-labeled acrylamide standard.
引用
收藏
页码:1877 / 1884
页数:8
相关论文
共 50 条
  • [21] Identification of heavily glycated proteoforms by hydrophilic-interaction liquid chromatography and native size-exclusion chromatography - High-resolution mass spectrometry
    Zhai, Ziran
    Schoenmakers, Peter J.
    Gargano, Andrea F. G.
    ANALYTICA CHIMICA ACTA, 2024, 1304
  • [22] On-line size-exclusion chromatography/mass spectrometry of low molecular mass heparin
    Henriksen, J
    Ringborg, LH
    Roepstorrf, P
    JOURNAL OF MASS SPECTROMETRY, 2004, 39 (11): : 1305 - 1312
  • [23] Quantitation of salbutamol in human urine by liquid chromatography-electrospray ionization mass spectrometry
    Zhang, JL
    Xu, YX
    Di, X
    Wu, MT
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 328 - 332
  • [24] Separation and identification of oligomeric phenylethoxysiloxanols by liquid chromatography-electrospray ionization mass spectrometry
    Jiang, Yuting
    Wan, Qian-Hong
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1394 : 95 - 102
  • [25] Determination of acrylamide in potato chips and crisps by high-performance liquid chromatography
    Gökmen, V
    Senyuva, HZ
    Acar, J
    Sarioglu, K
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1088 (1-2) : 193 - 199
  • [26] Determination of acrylamide in infant cereal-based foods by isotope dilution liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Zhang, Y
    Jiao, JJ
    Ren, YP
    Wu, XQ
    Zhang, Y
    ANALYTICA CHIMICA ACTA, 2005, 551 (1-2) : 150 - 158
  • [27] Determination of the carboxylic acid metabolite of clopidogrel in human plasma by liquid chromatography-electrospray ionization mass spectrometry
    Mitakos, A
    Panderi, I
    ANALYTICA CHIMICA ACTA, 2004, 505 (01) : 107 - 114
  • [28] Determination of the brominated flame retardant, hexabromocyclodocane, in sediments and biota by liquid chromatography-electrospray ionisation mass spectrometry
    Morris, S
    Bersuder, P
    Allchin, CR
    Zegers, B
    Boon, JP
    Leonards, PEG
    de Boer, J
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (04) : 343 - 349
  • [29] Estuarine/marine UDOM as characterized by size-exclusion chromatography and organic mass spectrometry
    Minor, EC
    Simjouw, JP
    Boon, JJ
    Kerkhoff, AE
    van der Horst, J
    MARINE CHEMISTRY, 2002, 78 (2-3) : 75 - 102
  • [30] Determination of acrylamide in starch-based foods by ion-exclusion liquid chromatography
    Geng, Zhiming
    Jiang, Rong
    Chen, Ming
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2008, 21 (02) : 178 - 182