Influence of Alveolar Bone Defects on he Stress Distribution in Quad Zygomatic Implant-Supported Maxillary Prosthesis
被引:14
作者:
Duan, Yuanyuan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Mississippi, Sch Dent, Med Ctr, Dept Biomed Mat Sci, 2500 N State St, Jackson, MS 39216 USAUniv Mississippi, Sch Dent, Med Ctr, Dept Biomed Mat Sci, 2500 N State St, Jackson, MS 39216 USA
Duan, Yuanyuan
[1
]
Chandran, Ravi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Mississippi, Sch Dent, Dept Oral Maxillofacial Surg & Pathol, Med Ctr, Jackson, MS 39216 USAUniv Mississippi, Sch Dent, Med Ctr, Dept Biomed Mat Sci, 2500 N State St, Jackson, MS 39216 USA
Chandran, Ravi
[2
]
Cherry, Denise
论文数: 0引用数: 0
h-index: 0
机构:
Univ Mississippi, Dept Biomed Mat Sci, Doctor Dent Med DMD Program, Sch Dent,Med Ctr, Jackson, MS 39216 USAUniv Mississippi, Sch Dent, Med Ctr, Dept Biomed Mat Sci, 2500 N State St, Jackson, MS 39216 USA
Cherry, Denise
[3
]
机构:
[1] Univ Mississippi, Sch Dent, Med Ctr, Dept Biomed Mat Sci, 2500 N State St, Jackson, MS 39216 USA
[2] Univ Mississippi, Sch Dent, Dept Oral Maxillofacial Surg & Pathol, Med Ctr, Jackson, MS 39216 USA
[3] Univ Mississippi, Dept Biomed Mat Sci, Doctor Dent Med DMD Program, Sch Dent,Med Ctr, Jackson, MS 39216 USA
Purpose: The purpose of this study was to create three-dimensional composite models of quad zygomatic implant-supported maxillary prostheses with a variety of alveolar bone defects around implant sites, and to investigate the stress distribution in the surrounding bone using the finite element analysis (FEA) method. Materials and Methods: Three-dimensional models of titanium zygomatic implants, maxillary prostheses, and human skulls were created and assembled using Mimics based on microcomputed tomography and cone beam computed tomography images. A variety of additional bone defects were created at the locations of four zygomatic implants to simulate multiple clinical scenarios. The volume meshes were created and exported into FEA software. Material properties were assigned respectively for all the structures, and von Mises stress data were collected and plotted in the postprocessing module. Results: The maximum stress in the surrounding bone was located in the crestal bone around zygomatic implants. The maximum stress in the prostheses was located at the angled area of the implant-abutment connection. The model with anterior defects had a higher peak stress value than the model with posterior defects. All the models with additional bone defects had higher maximum stress values than the control model without additional bone loss. Conclusion: Additional alveolar bone loss has a negative influence on the stress concentration in the surrounding bone of quad zygomatic implant-supported prostheses. More care should be taken if these additional bone defects are at the sites of anterior zygomatic implants.
机构:
Univ Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, SpainUniv Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, Spain
Saez-Alcaide, Luis Miguel
Cortes-Breton-Brinkmann, Jorge
论文数: 0引用数: 0
h-index: 0
机构:
Univ Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, SpainUniv Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, Spain
Cortes-Breton-Brinkmann, Jorge
Sanchez-Labrador, Luis
论文数: 0引用数: 0
h-index: 0
机构:
Univ Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, SpainUniv Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, Spain
Sanchez-Labrador, Luis
Perez-Gonzalez, Fabian
论文数: 0引用数: 0
h-index: 0
机构:
Univ Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, SpainUniv Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, Spain
Perez-Gonzalez, Fabian
Forteza-Lopez, Alba
论文数: 0引用数: 0
h-index: 0
机构:
Univ Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, SpainUniv Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, Spain
Forteza-Lopez, Alba
Molinero-Mourelle, Pedro
论文数: 0引用数: 0
h-index: 0
机构:
Univ Complutense Madrid, Dept Conservat Dent & Orofacial Prosthodon, Fac Dent, Madrid, Spain
Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, SwitzerlandUniv Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, Spain
Molinero-Mourelle, Pedro
Lopez-Quiles, Juan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, SpainUniv Complutense Madrid, Dept Dent Clin Specialties, Fac Dent, Plaza Ramon & Cajal S-N, Madrid 28040, Spain