Cerebral perfusion computed tomography deconvolution via structure tensor total variation regularization

被引:26
|
作者
Zeng, Dong [1 ,2 ]
Zhang, Xinyu [1 ,2 ]
Bian, Zhaoying [1 ,2 ]
Huang, Jing [1 ,2 ]
Zhang, Hua [1 ,2 ]
Lu, Lijun [1 ,2 ]
Lyu, Wenbing [1 ,2 ]
Zhang, Jing [3 ]
Feng, Qianjin [1 ,2 ]
Chen, Wufan [1 ,2 ]
Ma, Jianhua [1 ,2 ]
机构
[1] Southern Med Univ, Dept Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou 510515, Guangdong, Peoples R China
[3] Tianjin Med Univ, Gen Hosp, Dept Radiol, Tianjin 300052, Peoples R China
基金
中国国家自然科学基金;
关键词
cerebral perfusion computed tomography; low-mAs; deconvolution; structure tensor total variation; regularization; CLINICAL-APPLICATIONS; IMAGE-RECONSTRUCTION; NOISE-REDUCTION; CT; QUALITY; PARAMETERS; ALGORITHM; VOLUME; SCAN; FLOW;
D O I
10.1118/1.4944866
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Cerebral perfusion computed tomography (PCT) imaging as an accurate and fast acute ischemic stroke examination has been widely used in clinic. Meanwhile, a major drawback of PCT imaging is the high radiation dose due to its dynamic scan protocol. The purpose of this work is to develop a robust perfusion deconvolution approach via structure tensor total variation (STV) regularization (PD-STV) for estimating an accurate residue function in PCT imaging with the low-milliampere-seconds (low-mAs) data acquisition. Methods: Besides modeling the spatio-temporal structure information of PCT data, the STV regularization of the present PD-STV approach can utilize the higher order derivatives of the residue function to enhance denoising performance. To minimize the objective function, the authors propose an effective iterative algorithm with a shrinkage/thresholding scheme. A simulation study on a digital brain perfusion phantom and a clinical study on an old infarction patient were conducted to validate and evaluate the performance of the present PD-STV approach. Results: In the digital phantom study, visual inspection and quantitative metrics (i.e., the normalized mean square error, the peak signal-to-noise ratio, and the universal quality index) assessments demonstrated that the PD-STV approach outperformed other existing approaches in terms of the performance of noise-induced artifacts reduction and accurate perfusion hemodynamic maps (PHM) estimation. In the patient data study, the present PD-STV approach could yield accurate PHM estimation with several noticeable gains over other existing approaches in terms of visual inspection and correlation analysis. Conclusions: This study demonstrated the feasibility and efficacy of the present PD-STV approach in utilizing STV regularization to improve the accuracy of residue function estimation of cerebral PCT imaging in the case of low-mAs. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:2091 / 2107
页数:17
相关论文
共 50 条
  • [31] IMPROVED ULTRASOUND MICROVESSEL IMAGING USING DECONVOLUTION WITH TOTAL VARIATION REGULARIZATION
    Lok, U-Wai
    Trzasko, Joshua D.
    Huang, Chengwu
    Tang, Shanshan
    Gong, Ping
    Kim, Yohan
    Lucien, Fabrice
    Lowerison, Matthew R.
    Song, Pengfei
    Chen, Shigao
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (04): : 1089 - 1098
  • [32] Blind Poissonian image deconvolution with edge enhancing total variation regularization
    Shi Y.
    Hong H.
    Hua X.
    1600, Huazhong University of Science and Technology (44): : 94 - 98
  • [33] Hyperspectral Image Deconvolution with a Spectral-Spatial Total Variation Regularization
    Fang, Houzhang
    Luo, Chunan
    Zhou, Gang
    Wang, Xiaoping
    CANADIAN JOURNAL OF REMOTE SENSING, 2017, 43 (04) : 384 - 395
  • [34] Tensor integrated total variation regularization for thermography NDT of composites
    Ahmed, Junaid
    Tian, Guiyun
    Buriro, Abdul Baseer
    Baloch, Gulsher
    Soomro, Muhammad Waqas
    INFRARED PHYSICS & TECHNOLOGY, 2022, 123
  • [35] Poisson tensor completion with transformed correlated total variation regularization
    Feng, Qingrong
    Hou, Jingyao
    Kong, Weichao
    Xu, Chen
    Wang, Jianjun
    PATTERN RECOGNITION, 2024, 156
  • [36] Acousto-electric tomography with total variation regularization
    Adesokan, Bolaji James
    Jensen, Bjorn
    Jin, Bangti
    Knudsen, Kim
    INVERSE PROBLEMS, 2019, 35 (03)
  • [37] Iterative Reconstruction for Bioluminescence Tomography with Total Variation Regularization
    Jin, Wenma
    He, Yonghong
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS V, 2012, 8553
  • [38] Multifrequency electrical impedance tomography with total variation regularization
    Zhou, Zhou
    Dowrick, Thomas
    Malone, Emma
    Avery, James
    Li, Nan
    Sun, Zhaolin
    Xu, Hui
    Holder, David
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (09) : 1943 - 1961
  • [39] Wavelet representation and total variation regularization in emission tomography
    Kisilev, P
    Zibulevsky, M
    Zeevi, YY
    2001 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL I, PROCEEDINGS, 2001, : 702 - 705
  • [40] Total variation regularization used in electrical capacitance tomography
    Wang, Huaxiang
    Tang, Lei
    MULTIPHASE FLOW: THE ULTIMATE MEASUREMENT CHALLENGE, PROCEEDINGS, 2007, 914 : 911 - +