Experimental 193-nm excimer laser trephination with divergent cut angles in penetrating keratoplasty

被引:22
作者
Seitz, B [1 ]
Behrens, A [1 ]
Langenbucher, A [1 ]
Kus, MM [1 ]
Naumann, GOH [1 ]
机构
[1] Univ Erlangen Nurnberg, Augenklin, Poliklin, Dept Ophthalmol, D-91054 Erlangen, Germany
关键词
excimer laser; nonmechanical trephination; divergent cut angle; penetrating keratoplasty; suture technique; donor-recipient stability; morphological properties;
D O I
10.1097/00003226-199807000-00012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To study the morphologic properties of divergent cut. angles after nonmechanical trephination for penetrating keratoplasty in donors and recipients and to assess its implications for donor-recipient stability in an experimental porcine model. Methods. An excimer laser 193-nm corneal trephination was performed in 30 enucleated porcine eyes by using a modified ''open mask" (stainless steel sheet 10CrNi18), to obtain round donor buttons and corresponding recipient beds 7 mm in diameter at the level of Bowman's layer. An automated globe-rotation device allowed different cut angles toward the optical axis. Three cut angles were intended: 0 degrees, 15 degrees divergent, and 35 degrees divergent, Quality of the cuts was assessed by means of hislology and scanning electron microscopy (SEM).In a different setting, after alignment of the donor button and corresponding recipient bed in an artificial anterior chamber, intracameral pressure was increased stepwise, modifying the height of a bottle of balanced saline solution connected to the chamber. Criterion for "instability" was the movement of the donor button in all four quadrants during observation with a surgical microscope (x12). Results. Reproducible cut angles and smooth cut surfaces of donors and recipients were confirmed by histologic and SEM evaluation. Macroscopically, a good alignment of a divergent donor button in a corresponding recipient bed was achieved. Instability of the donor buttons occurred with a water column niveau at 2 cm in the 0 degrees cut, at 3 cm in 15 degrees divergent cuts, and at 4.5 cm in 35 degrees divergent cuts. Coraclusion, The stability of a corneal donor button in a recipient bed seems to increase in proportion with the degree of divergence of the trephination angle. Considering the good histologic quality and macroscopic alignment obtained. divergent cut angles may allow a reduction of sutures, assuring a water-light wound closure in penetrating keratoplasty.
引用
收藏
页码:410 / 416
页数:7
相关论文
共 50 条
[41]   Long-term refractive results of elliptical excimer laser penetrating keratoplasty (EELPK) [J].
Szentmary, Nora ;
Langenbucher, Achim ;
Kus, Murat M. ;
Naumann, Gottfried O. H. ;
Seitz, Berthold .
CURRENT EYE RESEARCH, 2007, 32 (11) :953-959
[42]   Long-term follow-up of Intraocular pressure after penetrating keratoplasty for keratoconus and Fuchs' dystrophy -: Comparison of mechanical and excimer laser trephination [J].
Seitz, B ;
Langenbucher, A ;
Nguyen, N ;
Küchle, M ;
Naumann, GOH .
CORNEA, 2002, 21 (04) :368-373
[43]   Subfoveal choroidal thickness increases after excimer laser-assisted penetrating keratoplasty but not after excimer laser-assisted deep anterior lamellar keratoplasty [J].
Aljundi, Wissam ;
Daas, Loay ;
Munteanu, Cristian ;
Seitz, Berthold ;
Abdin, Alaa Din .
SCIENTIFIC REPORTS, 2024, 14 (01)
[44]   Contact and proximity lithography using 193 nm Excimer laser in Mask Aligner [J].
Partel, S. ;
Zoppel, S. ;
Hudek, P. ;
Bich, A. ;
Vogler, U. ;
Hornung, M. ;
Voelkel, R. .
MICROELECTRONIC ENGINEERING, 2010, 87 (5-8) :936-939
[45]   ABLATION RATES AND SURFACE ULTRASTRUCTURE OF 193 NM EXCIMER-LASER KERATECTOMIES [J].
CAMPOS, M ;
WANG, XW ;
HERTZOG, L ;
LEE, M ;
CLAPHAM, T ;
TROKEL, SL ;
MCDONNELL, PJ .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (08) :2493-2500
[46]   A Comparison of Corneal Cellular Responses After 213-nm Compared With 193-nm Laser Photorefractive Keratectomy in Rabbits [J].
Sanders, Talia ;
Pujara, Tarak ;
Camelo, Serge ;
Lai, Ching Tat ;
Van Saarloos, Paul ;
Beazley, Lyn ;
Rodger, Jennifer .
CORNEA, 2009, 28 (04) :434-440
[47]   The effect of 193 nm excimer laser radiation on the human corneal endothelial cell density [J].
Isager, P ;
Hjortdal, JO ;
Ehlers, N .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1996, 74 (03) :224-227
[48]   Design of computer-generated hologram with ring focus for nonmechanical corneal trephination with Er:YAG laser in penetrating keratoplasty [J].
Langenbucher, A ;
Seitz, B ;
Kus, MM ;
van der Heyd, G ;
Köchle, M ;
Naumann, GOH .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 1999, 43 (06) :453-457
[49]   On interaction of 193 nm excimer laser with acetone (3s Rydberg state) [J].
Badr, Y ;
Mahmoud, MA .
JOURNAL OF MOLECULAR STRUCTURE, 2005, 748 (1-3) :189-193
[50]   Comparison of the Long-term Clinical Outcomes of Penetrating Keratoplasty Using a Manual Trephine and Femtosecond-Laser Trephination [J].
So, Ha-Rim ;
Kim, Seon-Joo ;
Joo, Choun-Ki ;
Hwang, You-Sook ;
Byun, Yong-Soo ;
Chung, So-Hyang ;
Kim, Hyun-Seung .
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (12) :1424-1432