Experimental 193-nm excimer laser trephination with divergent cut angles in penetrating keratoplasty

被引:22
作者
Seitz, B [1 ]
Behrens, A [1 ]
Langenbucher, A [1 ]
Kus, MM [1 ]
Naumann, GOH [1 ]
机构
[1] Univ Erlangen Nurnberg, Augenklin, Poliklin, Dept Ophthalmol, D-91054 Erlangen, Germany
关键词
excimer laser; nonmechanical trephination; divergent cut angle; penetrating keratoplasty; suture technique; donor-recipient stability; morphological properties;
D O I
10.1097/00003226-199807000-00012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To study the morphologic properties of divergent cut. angles after nonmechanical trephination for penetrating keratoplasty in donors and recipients and to assess its implications for donor-recipient stability in an experimental porcine model. Methods. An excimer laser 193-nm corneal trephination was performed in 30 enucleated porcine eyes by using a modified ''open mask" (stainless steel sheet 10CrNi18), to obtain round donor buttons and corresponding recipient beds 7 mm in diameter at the level of Bowman's layer. An automated globe-rotation device allowed different cut angles toward the optical axis. Three cut angles were intended: 0 degrees, 15 degrees divergent, and 35 degrees divergent, Quality of the cuts was assessed by means of hislology and scanning electron microscopy (SEM).In a different setting, after alignment of the donor button and corresponding recipient bed in an artificial anterior chamber, intracameral pressure was increased stepwise, modifying the height of a bottle of balanced saline solution connected to the chamber. Criterion for "instability" was the movement of the donor button in all four quadrants during observation with a surgical microscope (x12). Results. Reproducible cut angles and smooth cut surfaces of donors and recipients were confirmed by histologic and SEM evaluation. Macroscopically, a good alignment of a divergent donor button in a corresponding recipient bed was achieved. Instability of the donor buttons occurred with a water column niveau at 2 cm in the 0 degrees cut, at 3 cm in 15 degrees divergent cuts, and at 4.5 cm in 35 degrees divergent cuts. Coraclusion, The stability of a corneal donor button in a recipient bed seems to increase in proportion with the degree of divergence of the trephination angle. Considering the good histologic quality and macroscopic alignment obtained. divergent cut angles may allow a reduction of sutures, assuring a water-light wound closure in penetrating keratoplasty.
引用
收藏
页码:410 / 416
页数:7
相关论文
共 50 条
[31]   Results of excimer laser penetrating keratoplasty in aphakic eyes [J].
Ninios, K. ;
Matoula, P. ;
Szentmary, N. ;
Schirra, F. ;
Seitz, B. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (04) :1185-1189
[32]   Results of excimer laser penetrating keratoplasty in aphakic eyes [J].
K. Ninios ;
P. Matoula ;
N. Szentmary ;
F. Schirra ;
B. Seitz .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 :1185-1189
[33]   Ultra-high-repetition-rate ArF excimer laser with long pulse duration for 193-nm lithography [J].
Kakizaki, K ;
Matsunaga, T ;
Sasaki, Y ;
Inoue, T ;
Tanaka, S ;
Tada, A ;
Taniguchi, H ;
Arai, M ;
Igarashi, T .
OPTICAL MICROLITHOGRAPHY XIV, PTS 1 AND 2, 2001, 4346 :1210-1218
[34]   Excimer laser "corneal shaping": a new technique for customized trephination in penetrating keratoplastyFirst experimental results in rabbits [J].
Klaus Schmitz ;
Wolfram Schreiber ;
Wolfgang Behrens-Baumann .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2003, 241 :423-431
[35]   Development of Endothelial Cell Density after Penetrating Keratoplasty in Patients with Fuchs Dystrophy or Keratoconus - Comparison of Excimer Laser and Mechanical Trephination [J].
Schumacher, M. ;
Langenbucher, A. ;
Seitz, B. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2017, 234 (05) :697-705
[36]   Challenges of laser spectrum metrology in 248 and 193-nm lithography [J].
Ershov, A ;
Smith, S .
OPTICAL MICROLITHOGRAPHY XIV, PTS 1 AND 2, 2001, 4346 :1219-1228
[37]   A 193nm excimer laser microstepper system [J].
Rizvi, NH ;
Cashmore, JS ;
Solomon, CM ;
Rumsby, PT ;
Gower, MC .
MICROLITHOGRAPHIC TECHNIQUES IN IC FABRICATION, 1997, 3183 :30-37
[38]   Zinc ion and neutral emission from single crystal zinc oxide during 193-nm excimer laser exposure [J].
Khan, Enamul ;
Langford, S. C. ;
Boatner, L. A. ;
Dickinson, J. T. .
LASER APPLICATIONS IN MICROELECTRONIC AND OPTOELECTRONIC MANUFACTURING (LAMOM) XVI, 2011, 7920
[39]   Penetrating keratoplasty in free form using the excimer laser first application in a patient [J].
Schmitz, K ;
Behrens-Baumann, W .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2003, 220 (04) :247-252
[40]   Top-hat Shaped Corneal Trephination for Penetrating Keratoplasty Using the Femtosecond Laser: A Histomorphological Study [J].
Kook, Daniel ;
Derhartunian, Victor ;
Bug, Reinhold ;
Kohnen, Thomas .
CORNEA, 2009, 28 (07) :795-800