Experimental 193-nm excimer laser trephination with divergent cut angles in penetrating keratoplasty

被引:22
|
作者
Seitz, B [1 ]
Behrens, A [1 ]
Langenbucher, A [1 ]
Kus, MM [1 ]
Naumann, GOH [1 ]
机构
[1] Univ Erlangen Nurnberg, Augenklin, Poliklin, Dept Ophthalmol, D-91054 Erlangen, Germany
关键词
excimer laser; nonmechanical trephination; divergent cut angle; penetrating keratoplasty; suture technique; donor-recipient stability; morphological properties;
D O I
10.1097/00003226-199807000-00012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To study the morphologic properties of divergent cut. angles after nonmechanical trephination for penetrating keratoplasty in donors and recipients and to assess its implications for donor-recipient stability in an experimental porcine model. Methods. An excimer laser 193-nm corneal trephination was performed in 30 enucleated porcine eyes by using a modified ''open mask" (stainless steel sheet 10CrNi18), to obtain round donor buttons and corresponding recipient beds 7 mm in diameter at the level of Bowman's layer. An automated globe-rotation device allowed different cut angles toward the optical axis. Three cut angles were intended: 0 degrees, 15 degrees divergent, and 35 degrees divergent, Quality of the cuts was assessed by means of hislology and scanning electron microscopy (SEM).In a different setting, after alignment of the donor button and corresponding recipient bed in an artificial anterior chamber, intracameral pressure was increased stepwise, modifying the height of a bottle of balanced saline solution connected to the chamber. Criterion for "instability" was the movement of the donor button in all four quadrants during observation with a surgical microscope (x12). Results. Reproducible cut angles and smooth cut surfaces of donors and recipients were confirmed by histologic and SEM evaluation. Macroscopically, a good alignment of a divergent donor button in a corresponding recipient bed was achieved. Instability of the donor buttons occurred with a water column niveau at 2 cm in the 0 degrees cut, at 3 cm in 15 degrees divergent cuts, and at 4.5 cm in 35 degrees divergent cuts. Coraclusion, The stability of a corneal donor button in a recipient bed seems to increase in proportion with the degree of divergence of the trephination angle. Considering the good histologic quality and macroscopic alignment obtained. divergent cut angles may allow a reduction of sutures, assuring a water-light wound closure in penetrating keratoplasty.
引用
收藏
页码:410 / 416
页数:7
相关论文
共 50 条
  • [1] 193 NM EXCIMER-LASER TREPHINATION IN PENETRATING KERATOPLASTY
    NAUMANN, GOH
    SEITZ, B
    LANG, GK
    LANGENBUCHER, A
    KUS, MM
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 203 (04) : 252 - 261
  • [2] Regularity of corneal topography after penetrating keratoplasty - Nonmechanical trephination with the excimer laser 193 nm vs mechanical trephination
    Langenbucher, A
    Seitz, B
    Kus, MM
    Vilchis, E
    Naumann, GOH
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1996, 208 (06) : 450 - 458
  • [3] Donor decentration of mechanical and excimer laser trephination for penetrating keratoplasty
    Seitz, B
    Langenbucher, A
    Meiller, R
    Kus, MM
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2000, 217 (03) : 144 - 151
  • [4] Vertical tilt after penetrating keratoplasty - Comparison between nonmechanical trephination with the excimer laser and motor trephination
    Langenbucher, A
    Seitz, B
    Kus, MM
    Naumann, GOH
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1998, 212 (03) : 129 - 140
  • [5] Q-switched 2.94-μm Er:YAG laser trephination with convergent and divergent cut angles for penetrating keratoplasty
    de Souza, RF
    Seitz, B
    Langenbucher, A
    Hofmann-Rummelt, C
    Schlötzer-Schrehardt, U
    Viestenz, A
    Küchle, M
    Naumann, GOH
    CORNEA, 2003, 22 (06) : 562 - 568
  • [6] Corneal wound healing after experimental penetrating keratoplasty after excimer laser trephination in free form
    Schmitz, K.
    Lang, G. K.
    Behrens-Baumann, W.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2006, 223 (12) : 957 - 965
  • [7] Subpicometer ArF excimer laser for 193-nm lithography
    Akita, J
    Komori, H
    Kouda, N
    Yoshioka, S
    Itakura, Y
    Mizoguchi, H
    OPTICAL MICROLITHOGRAPHY X, 1997, 3051 : 890 - 898
  • [8] Therapeutic use of the 193-nm excimer laser in corneal pathologies
    Werner Förster
    Ulrich Atzler
    Imola Ratkay
    Holger Busse
    Graefe's Archive for Clinical and Experimental Ophthalmology, 1997, 235 : 296 - 305
  • [9] TRANSCONJUNCTIVAL SINUSOTOMY USING THE 193-NM EXCIMER-LASER
    CAMPOS, M
    LEE, PP
    TROKEL, SL
    TAYLOR, HR
    MCDONNELL, PJ
    ACTA OPHTHALMOLOGICA, 1994, 72 (06): : 707 - 711
  • [10] Interpretation of corneal topography with wave-front parameters after penetrating keratoplasty - Comparison between nonmechanical trephination with the excimer laser and motor trephination
    Langenbucher, A
    Seitz, B
    Kus, MM
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1998, 212 (06) : 433 - 443