Investigation on the properties of a laminar grating as a soft x-ray beam splitter

被引:5
|
作者
Liu, Ying [1 ,2 ]
Fuchs, Hans-Joerg [1 ]
Liu, Zhengkun [2 ]
Chen, Huoyao [2 ]
He, Shengnan [2 ]
Fu, Shaojun [2 ]
Kley, Ernst-Bernhard [1 ]
Tuennermann, Andreas [1 ]
机构
[1] Univ Jena, Inst Angew Phys, D-07743 Jena, Germany
[2] Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Peoples R China
关键词
COUPLED-WAVE ANALYSIS; DIFFRACTION GRATINGS; WAVELENGTH REGION; LASER; INTERFEROMETRY; IMPLEMENTATION; EFFICIENCIES; DIAGNOSTICS; PLASMAS;
D O I
10.1364/AO.49.004450
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Laminar-type gratings as soft x-ray beam splitters for interferometry are presented. Gold-coated grating beam splitters with 1000 lines/mm are designed for grazing incidence operation at 13: 9 nm. They are routinely fabricated using electron beam lithography and ion etching techniques. The laminar grating is measured to have almost equal absolute efficiencies of about 20% in the zeroth and -1st orders, which enables a fringe visibility up to 0.99 in the interferometer. The discrepancy of the grating profiles between the optimized theoretical and the experimental results is analyzed according to the comparison of the optimized simulation results and the measurement realization of the grating efficiencies. By a precise control of the grating profile, the grating efficiency in the -1st order and the fringe visibility could be improved to 25% and 1, respectively. (C) 2010 Optical Society of America
引用
收藏
页码:4450 / 4459
页数:10
相关论文
共 50 条
  • [21] CALCULATIONS OF GRATING EFFICIENCY IN THE SOFT X-RAY REGION
    SPRAGUE, G
    TOMBOULIAN, DH
    BEDO, DE
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1955, 45 (09) : 756 - 761
  • [22] Soft X-ray multilayer beam splitters
    Haga, T
    Tinone, MCK
    Shimada, M
    Ohkubo, T
    Ozawa, A
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 690 - 692
  • [23] Soft X-ray multilayer beam splitters
    Haga, Tsuneyuki
    Tinone, Marcia C. K.
    Shimada, Masaru
    Ohkubo, Takashi
    Ozawa, Akira
    Journal of Synchrotron Radiation, 1998, 5 (03): : 690 - 692
  • [24] Fast soft X-ray beam shutter
    Kilcoyne, ALD
    Tyliszczak, T
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 605 - 607
  • [25] Soft X-ray properties of LINERs
    Komossa, S
    Böhringer, H
    Huchra, J
    ASTRONOMISCHE NACHRICHTEN, 1999, 320 (4-5) : 301 - 301
  • [26] X-ray crystallography - Beam splitter teases out phase secrets
    Service, RF
    SCIENCE, 1998, 280 (5365) : 828 - 828
  • [27] Soft x-ray emission and absorption spectra with tangential grating
    Thibaud, J
    NATURE, 1928, 121 : 321 - 322
  • [28] A slit grating spectrograph for quantitative soft x-ray spectroscopy
    Wilhein, T
    Rehbein, S
    Hambach, D
    Berglund, M
    Rymell, L
    Hertz, HM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03): : 1694 - 1699
  • [30] Design and fabrication of soft X-ray double frequency grating
    Liu, Z.-K. (zhkliu@ustc.edu.cn), 1780, Chinese Academy of Sciences (21):