The effects of pupil size on the multifocal electroretinogram

被引:13
|
作者
Gonzalez, P
Parks, S
Dolan, F
Keating, D
机构
[1] Gartnavel Royal Hosp, Tennent Inst Ophthalmol, Electrodiagnost Imaging Unit, Glasgow G12 0YN, Lanark, Scotland
[2] Univ Glasgow, Gartnavel Gen Hosp, Vis Sci Res Grp, Glasgow, Lanark, Scotland
关键词
multifocal electroretinogram; P1 amplitude and latency; pupil;
D O I
10.1007/s10633-004-1545-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This is an investigation of the effect of changing the pupil diameter on the PI amplitude and latency of the multifocal electroretinogram (mfERG). MfERGs were recorded using a custom built wide field electrophysiological system. An array of 61 empirically scaled hexagons was used to stimulate the visual field. The duration of overall recording period was 8 min, segmented into 16 intervals each lasting 30 s. A combination of mydriatics and miotics were used to pharmacologically alter the pupil size and diameters between 1 and 10 mm were measured. There was a reduction in mfERG P1 amplitude in some cases greater than 50% (mfERG P1 amplitude 53 nV at 8 mm to 25 nV at 1 mm): with a change in pupil diameter of 7 mm. The mfERG P1 latency increased in some cases by as much as 8 ms in the central 40degrees (mfERG P1 latency 39 ms at 8 mm to 47 ms at 1 mm). These results suggest that pupil size has significant effects on mfERG P1 amplitude and latency.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 50 条
  • [21] The Multifocal electroretinogram in Chinese high myopia
    Wu, XW
    Gong, Y
    Wang, H
    Sun, Y
    Zhu, P
    Xu, X
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [22] Slow flash multifocal electroretinogram in myopia
    Chen, Jennifer C.
    Brown, Brian
    Schmid, Katrina L.
    VISION RESEARCH, 2006, 46 (18) : 2869 - 2876
  • [23] Oscillatory potentials of multifocal electroretinogram in diabetic retinopathy
    Onozu, H
    Yamamoto, S
    DOCUMENTA OPHTHALMOLOGICA, 2003, 106 (03) : 327 - 332
  • [24] Artifact Removal procedure distorts multifocal electroretinogram
    Yoshii, M
    Yanashima, K
    Suzuki, S
    Okisaka, S
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2000, 44 (04) : 419 - 423
  • [25] Lateral spread of adaptation as measured with the multifocal electroretinogram
    Seiple, W
    Vajaranant, TS
    Pepperberg, DR
    Szlyk, JP
    VISUAL NEUROSCIENCE, 2001, 18 (05) : 687 - 694
  • [26] Effects of changes in pupil centration and pupil size on the output of video eye trackers
    Wildenmann, Ulrich
    Schaeffel, Frank
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [27] Multifocal electroretinogram in patients with central serous chorioretinopathy
    Suzuki, K
    Hasegawa, S
    Usui, T
    Ichibe, M
    Takada, R
    Takagi, M
    Abe, H
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2002, 46 (03) : 308 - 314
  • [28] The multifocal electroretinogram in age-related maculopathies
    Huang S.
    Wu D.
    Jiang F.
    Ma J.
    Wu L.
    Liang J.
    Luo G.
    Documenta Ophthalmologica, 2000, 101 (2) : 115 - 124
  • [29] Oscillatory potentials of multifocal electroretinogram in diabetic retinopathy
    Hiroyuki Onozu
    Shuichi Yamamoto
    Documenta Ophthalmologica, 2003, 106 : 327 - 332
  • [30] The Effects of Age, Refractive Status, and Luminance on Pupil Size
    Guillon, Michel
    Dumbleton, Kathryn
    Theodoratos, Panagiotis
    Gobbe, Marine
    Wooley, C. Benjamin
    Moody, Kurt
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (09) : 1093 - 1100