The effects of pupil size on the multifocal electroretinogram

被引:13
|
作者
Gonzalez, P
Parks, S
Dolan, F
Keating, D
机构
[1] Gartnavel Royal Hosp, Tennent Inst Ophthalmol, Electrodiagnost Imaging Unit, Glasgow G12 0YN, Lanark, Scotland
[2] Univ Glasgow, Gartnavel Gen Hosp, Vis Sci Res Grp, Glasgow, Lanark, Scotland
关键词
multifocal electroretinogram; P1 amplitude and latency; pupil;
D O I
10.1007/s10633-004-1545-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This is an investigation of the effect of changing the pupil diameter on the PI amplitude and latency of the multifocal electroretinogram (mfERG). MfERGs were recorded using a custom built wide field electrophysiological system. An array of 61 empirically scaled hexagons was used to stimulate the visual field. The duration of overall recording period was 8 min, segmented into 16 intervals each lasting 30 s. A combination of mydriatics and miotics were used to pharmacologically alter the pupil size and diameters between 1 and 10 mm were measured. There was a reduction in mfERG P1 amplitude in some cases greater than 50% (mfERG P1 amplitude 53 nV at 8 mm to 25 nV at 1 mm): with a change in pupil diameter of 7 mm. The mfERG P1 latency increased in some cases by as much as 8 ms in the central 40degrees (mfERG P1 latency 39 ms at 8 mm to 47 ms at 1 mm). These results suggest that pupil size has significant effects on mfERG P1 amplitude and latency.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 50 条
  • [1] The effects of pupil size on the multifocal electroretinogram
    P. Gonzalez
    S. Parks
    F. Dolan
    D. Keating
    Documenta Ophthalmologica, 2004, 109 : 67 - 72
  • [2] The Effects of Non-Dilated and Dilated Pupil at Different Eccentricity on Multifocal Electroretinogram
    Mohamad-Rafiuddin, Muhamad-Syukri
    Rosli, Saiful Azlan
    Chen, Ai-Hong
    Wan-Hamat, Wan-Nurdiana
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [3] The effects of fundus photography on the multifocal electroretinogram
    Suresh, Sandip
    Tienor, Brian J.
    Smith, Scott D.
    Lee, Michael S.
    DOCUMENTA OPHTHALMOLOGICA, 2016, 132 (01) : 39 - 45
  • [4] Effects of refractive blur on the multifocal electroretinogram
    Palmowski, AM
    Berninger, T
    Allgayer, R
    Andrielis, H
    Heinemann-Vernaleken, B
    Rudolph, G
    DOCUMENTA OPHTHALMOLOGICA, 1999, 99 (01) : 41 - 54
  • [5] Effects of refractive blur on the multifocal electroretinogram
    Anja M. Palmowski
    Thomas Berninger
    Reiner Allgayer
    Harry Andrielis
    Bernhild Heinemann-Vernaleken
    G. Rudolph
    Documenta Ophthalmologica, 1999, 99
  • [6] The effects of fundus photography on the multifocal electroretinogram
    Sandip Suresh
    Brian J. Tienor
    Scott D. Smith
    Michael S. Lee
    Documenta Ophthalmologica, 2016, 132 : 39 - 45
  • [7] Effects of unsteady fixation on multifocal electroretinogram (mfERG)
    Chu, Patrick H. W.
    Chan, Henry H. L.
    Leat, Susan J.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (10) : 1273 - 1282
  • [8] Effects of different degrees of cataract on the multifocal electroretinogram
    W-K Tam
    H Chan
    B Brown
    M Yap
    Eye, 2004, 18 : 691 - 696
  • [9] Acute effects of cigarette smoking on multifocal electroretinogram
    Gundogan, Fatih C.
    Erdurman, Cuneyt
    Durukan, Ali H.
    Sobaci, Gungor
    Bayraktar, M. Zeki
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (01) : 32 - 37
  • [10] Effects of unsteady fixation on multifocal electroretinogram (mfERG)
    Patrick H. W. Chu
    Henry H. L. Chan
    Susan J. Leat
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 1273 - 1282