PURPOSE. To compare central corneal thickness (CCT) measurements obtained using the Pentacam Scheimpflug system with those obtained using DGH ultrasound pachymetry (UP) in post-laser in situ keratomileusis (LASIK) eyes for myopia. METHODS. In a prospective study, measurement agreement was assessed in 143 eyes of 72 post-LASIK patients using both the Pentacam and UP at the Eye Consultants Center in Riyadh, Saudi Arabia. RESULTS. The mean CCT was 522+/-42.2 mu m with the Oculus Pentacam and 516.2+/-40.6 mu m with UP. The Bland-Altman plot showed that the mean +/-SD for the differences between the 2 devices was 5.8+/-13.6 mu m, with 95% confidence interval limits ranging from -20.9 mu m to 32.6 mu m. A test of statistical significance indicated that the mean differences of 5.8+/-13.6 mu m differed significantly from zero (p<0.001; Wilcoxon signed-rank test), thus indicating that the Pentacam measurements tended to overestimate CCT compared with UP. Analysis of regression showed a high correlation between the values obtained with both devices (r=0.947, p<0.001). CONCLUSIONS. In post-LASIK myopic eyes, although a high correlation has been shown between Pentacam and UP measurements, Pentacam tends to overestimate CCT compared to UP. Pentacam probably cannot be used interchangeably with UP in post-LASIK eyes for myopia. (Eur J Ophthalmol 2010; 20: 852-7)
机构:
Univ Santiago de Compostela, Fac Optometry, Ocular Surface & Contact Lens Res Lab, Santiago De Compostela, SpainUniv Santiago de Compostela, Fac Optometry, Ocular Surface & Contact Lens Res Lab, Santiago De Compostela, Spain
Gonzalez-Perez, Javier
Queiruga Pineiro, Juan
论文数: 0引用数: 0
h-index: 0
机构:
Inst Oftalmol Fernandez Vega, Oviedo, SpainUniv Santiago de Compostela, Fac Optometry, Ocular Surface & Contact Lens Res Lab, Santiago De Compostela, Spain
Queiruga Pineiro, Juan
Sanchez Garcia, Angelx
论文数: 0引用数: 0
h-index: 0
机构:
Univ Santiago de Compostela, Fac Optometry, Ocular Surface & Contact Lens Res Lab, Santiago De Compostela, SpainUniv Santiago de Compostela, Fac Optometry, Ocular Surface & Contact Lens Res Lab, Santiago De Compostela, Spain
Sanchez Garcia, Angelx
Gonzalez Meijome, Jose Manuel
论文数: 0引用数: 0
h-index: 0
机构:
Univ Santiago de Compostela, Fac Optometry, Ocular Surface & Contact Lens Res Lab, Santiago De Compostela, Spain
Univ Minho, Clin & Expt Optometry Res Lab, Sch Sci, Ctr Phys Optometry, Gualtar Braga, PortugalUniv Santiago de Compostela, Fac Optometry, Ocular Surface & Contact Lens Res Lab, Santiago De Compostela, Spain
机构:
Univ Manchester, Fac Life Sci, Dept Optometry, Manchester M60 1QD, Lancs, EnglandUniv Manchester, Fac Life Sci, Dept Optometry, Manchester M60 1QD, Lancs, England
O'Donnell, C
Maldonado-Codina, C
论文数: 0引用数: 0
h-index: 0
机构:
Univ Manchester, Fac Life Sci, Dept Optometry, Manchester M60 1QD, Lancs, EnglandUniv Manchester, Fac Life Sci, Dept Optometry, Manchester M60 1QD, Lancs, England
机构:
Univ Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, England
Optegra Manchester Eye Hosp, Manchester, Lancs, EnglandUniv Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, England
O'Donnell, Clare
Hartwig, Andreas
论文数: 0引用数: 0
h-index: 0
机构:
Univ Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, EnglandUniv Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, England
Hartwig, Andreas
Radhakrishnan, Hema
论文数: 0引用数: 0
h-index: 0
机构:
Univ Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, EnglandUniv Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, England