Comparison of central corneal thickness measurements using Pentacam and ultrasonic pachymetry in post-LASIK eyes for myopia

被引:12
|
作者
Al-Mezaine, Hani S. [1 ]
Al-Amro, Saleh A. [1 ]
Kangave, Dustan [2 ]
Al-Obeidan, Saleh [1 ]
Al-Jubair, Khaled M. [3 ]
机构
[1] King Saud Univ, Coll Med, Dept Ophthalmol, Riyadh 11321, Saudi Arabia
[2] King Saud Univ, Coll Med, Res Dept, Riyadh 11321, Saudi Arabia
[3] Natl Guard Hosp, Dept Ophthalmol, Riyadh, Saudi Arabia
关键词
Corneal thickness; Laser in situ keratomileusis; Pachymetry; Pentacam; Ultrasound; NONCONTACT SPECULAR MICROSCOPY; IN-SITU KERATOMILEUSIS; ANTERIOR-CHAMBER DEPTH; REFRACTIVE SURGERY; ORBSCAN-II; SCHEIMPFLUG PHOTOGRAPHY; OCULUS PENTACAM; REPEATABILITY; PACHOMETRY; OXYBUPROCAINE;
D O I
10.1177/112067211002000507
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare central corneal thickness (CCT) measurements obtained using the Pentacam Scheimpflug system with those obtained using DGH ultrasound pachymetry (UP) in post-laser in situ keratomileusis (LASIK) eyes for myopia. METHODS. In a prospective study, measurement agreement was assessed in 143 eyes of 72 post-LASIK patients using both the Pentacam and UP at the Eye Consultants Center in Riyadh, Saudi Arabia. RESULTS. The mean CCT was 522+/-42.2 mu m with the Oculus Pentacam and 516.2+/-40.6 mu m with UP. The Bland-Altman plot showed that the mean +/-SD for the differences between the 2 devices was 5.8+/-13.6 mu m, with 95% confidence interval limits ranging from -20.9 mu m to 32.6 mu m. A test of statistical significance indicated that the mean differences of 5.8+/-13.6 mu m differed significantly from zero (p<0.001; Wilcoxon signed-rank test), thus indicating that the Pentacam measurements tended to overestimate CCT compared with UP. Analysis of regression showed a high correlation between the values obtained with both devices (r=0.947, p<0.001). CONCLUSIONS. In post-LASIK myopic eyes, although a high correlation has been shown between Pentacam and UP measurements, Pentacam tends to overestimate CCT compared to UP. Pentacam probably cannot be used interchangeably with UP in post-LASIK eyes for myopia. (Eur J Ophthalmol 2010; 20: 852-7)
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [31] Comparison of Central Corneal Thickness Measured by Standard Ultrasound Pachymetry, Corneal Topography, Tono-Pachymetry and Anterior Segment Optical Coherence Tomography
    Gonzalez-Perez, Javier
    Queiruga Pineiro, Juan
    Sanchez Garcia, Angelx
    Gonzalez Meijome, Jose Manuel
    CURRENT EYE RESEARCH, 2018, 43 (07) : 866 - 872
  • [32] Comparison of Central Corneal Thickness Measurements Using Ultrasonic Pachymetry, Anterior Segment OCT and Noncontact Specular Microscopy
    Scotto, Riccardo
    Bagnis, Alessandro
    Papadia, Marina
    Cutolo, Carlo Alberto
    Risso, Domenico
    Traverso, Carlo Enrico
    JOURNAL OF GLAUCOMA, 2017, 26 (10) : 860 - 865
  • [33] Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS pentacam
    O'Donnell, C
    Maldonado-Codina, C
    CORNEA, 2005, 24 (08) : 920 - 924
  • [34] Comparison of central corneal thickness measured in myopic eyes by Pentacam, Sirius and IOLMaster 700
    Song, Han
    Liu, Chengyang
    Yang, Wei
    Yang, Chunliu
    Cheng, Xiaodong
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2024, 49
  • [35] Comparison of Central Corneal Thickness and Anterior Chamber Depth Measured Using LenStar LS900, Pentacam, and Visante AS-OCT
    O'Donnell, Clare
    Hartwig, Andreas
    Radhakrishnan, Hema
    CORNEA, 2012, 31 (09) : 983 - 988
  • [36] Central Corneal Thickness Measurements With Different Imaging Devices and Ultrasound Pachymetry
    Tai, Lai-Yong
    Khaw, Keat-Ween
    Ng, Choung-Min
    Subrayan, Visvaraja
    CORNEA, 2013, 32 (06) : 766 - 771
  • [37] Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery
    Jumpei Matsuda
    Osamu Hieda
    Shigeru Kinoshita
    Japanese Journal of Ophthalmology, 2008, 52 : 245 - 249
  • [38] Comparison of central corneal thickness measurements using different imaging devices and ultrasound pachymetry
    Can, Ertugrul
    Eser-Ozturk, Hilal
    Duran, Mustafa
    Cetinkaya, Tugba
    Ariturk, Nursen
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10)
  • [39] Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery
    Matsuda, Jumpei
    Hieda, Osamu
    Kinoshita, Shigeru
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2008, 52 (04) : 245 - 249
  • [40] Comparison of two partial coherence interferometers for corneal pachymetry in high myopia and after LASIK
    Ivarsen, Anders
    Ehlers, Niels
    Hjortdal, Jesper
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 392 - 395