Analysis of water flow in rock by a Tracer-aided X-ray CT

被引:0
|
作者
Sugawara, K [1 ]
Fukahori, D [1 ]
Iwatani, I [1 ]
Kubota, S [1 ]
机构
[1] Kumamoto Univ, Grad Sch Sci & Technol, Kumamoto 860, Japan
关键词
D O I
暂无
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
A new scheme named the Tracer Density Time-integration Method (TDTIM) is proposed to evaluate the ununiformity of a steady water flow in rock by means of the X-ray CT. Transport diffusion phenomenon of a tracer is analyzed to determine the distribution of flow rate. Tracer mainly composed of potassium iodide is utilized, preparing the viscosity of water-tracer mixture to be equivalent to pure water in a wide range of the tracer density. The CT images subtraction technique is applied to evaluate the tracer density at points within a rock specimen. Subsequent time-integration of the tracer density provides the simultaneous linear equation for the pore-water pressure, and the flow rate of water is determined, basing upon the Darcy law. Case examples clarify that the present method is a promising tool available for evaluating the fluctuation of water flow deeply influenced by heterogeneities in rock.
引用
收藏
页码:335 / 345
页数:11
相关论文
共 50 条
  • [31] ROC ANALYSIS OF DYNAMIC DISPLAYS X-RAY CT
    TSUJIOKA, K
    KATADA, K
    ANNO, H
    KOGA, S
    SUZUKI, J
    RADIOLOGY, 1995, 197 : 357 - 357
  • [32] Analysis and correction of artifacts in X-ray industrial CT
    Zhang, QH
    Lu, HN
    Yang, M
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 4999 - 5003
  • [33] STATIC ROCK CHARACTERIZATION OF ROCKS USING X-RAY COMPUTED TOMOGRAPHY CT
    Ortiz Meneses, Andres F.
    Plata Chaves, Jose M.
    Herrera Otero, Edwar
    Santos Santos, Nicolas
    FUENTES EL REVENTION ENERGETICO, 2015, 13 (01): : 57 - 63
  • [34] A Review of Particle Size Analysis with X-ray CT
    Behnsen, Julia G.
    Black, Kate
    Houghton, James E.
    Worden, Richard H.
    MATERIALS, 2023, 16 (03)
  • [35] X-ray CT analysis of pore structure in sand
    Mukunoki, Toshifumi
    Miyata, Yoshihisa
    Mikami, Kazuaki
    Shiota, Erika
    SOLID EARTH, 2016, 7 (03) : 929 - 942
  • [36] An analysis of semiconductor package by X-ray CT instrument
    Takado, T
    Arita, H
    Ohno, Y
    Ohnishi, SH
    Hirakimoto, A
    2000 INTERNATIONAL SYMPOSIUM ON MICROELECTRONICS, 2000, 4339 : 128 - 133
  • [37] Projecting climate change impacts on stream flow regimes with tracer-aided runoff models - preliminary assessment of heterogeneity at the mesoscale
    Capell, R.
    Tetzlaff, D.
    Essery, R.
    Soulsby, C.
    HYDROLOGICAL PROCESSES, 2014, 28 (03) : 545 - 558
  • [38] Groundwater-surface water interactions in a semi-arid irrigated agricultural valley: A hydrometric and tracer-aided approach
    Liberoff, Ana Laura
    Poca, Maria
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 903
  • [39] A new method for computer aided detection of pulmonary nodules in X-ray CT images
    Homma, Noriyasu
    Takei, Kazunori
    Ishibashi, Tadashi
    ADVANCES ON ARTIFICIAL INTELLIGENCE, KNOWLEDGE ENGINEERING AND DATA BASES, PROCEEDINGS, 2008, : 379 - +
  • [40] Spatially distributed tracer-aided modelling to explore water and isotope transport, storage and mixing in a pristine, humid tropical catchment
    Dehaspe, Joni
    Birkel, Christian
    Tetzlaff, Doerthe
    Sanchez-Murillo, Ricardo
    Duran-Quesada, Ana Maria
    Soulsby, Chris
    HYDROLOGICAL PROCESSES, 2018, 32 (21) : 3206 - 3224