The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy

被引:5
|
作者
Inferrera, Leandro [1 ,2 ]
Aragona, Emanuela [3 ]
Wylegala, Adam [4 ]
Valastro, Antonio [2 ]
Latino, Gianluigi [2 ]
Postorino, Elisa, I [2 ]
Gargano, Romana [5 ]
Orzechowska-Wylegala, Boguslawa [6 ]
Wylegala, Edward [7 ]
Roszkowska, Anna M. [2 ,8 ]
机构
[1] Univ Trieste, Dept Med Surg Sci & Hlth, Eye Clin, I-34100 Trieste, Italy
[2] Univ Messina, Dept Biomed Sci, Ophthalmol Clin, I-98100 Messina, Italy
[3] Univ Vita Salute San Raffaele, IRCCS San Raffaele Sci Inst, Ophthalmol Clin, I-20132 Milan, Italy
[4] Med Univ Silesia, Sch Med, Pathophysiol Dept, Hlth Promot & Obes Management Unit, PL-40055 Katowice, Poland
[5] Univ Messina, Dept Econ, I-98100 Messina, Italy
[6] Med Univ Silesia, Dept Pediat Surg, Clin Otolaryngol Head & Neck Surg, PL-40055 Katowice, Poland
[7] Med Univ Silesia, Chair & Clin Dept Ophthalmol, Div Med Sci Zabrze, PL-40055 Katowice, Poland
[8] Andrzej Frycz Modrzewski Krakow Univ, Fac Med & Hlth Sci, Ophthalmol Dept, PL-30705 Krakow, Poland
关键词
AS-OCT; Keratograph; 5M; high-tech diagnostics; neurotrophic keratopathy; rh-NGF; persistent epithelial defects; corneal ulcers; corneal healing; OPTICAL COHERENCE TOMOGRAPHY; VIVO-CONFOCAL-MICROSCOPY; NERVE GROWTH-FACTOR; AUTOLOGOUS SERUM; TOPICAL TREATMENT; OCULAR SURFACE; BOWMANS LAYER; EYE DROPS; KERATOCONUS; OCT;
D O I
10.3390/jcm11061602
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To prove the role of high-tech investigation in monitoring corneal morphological changes in patients with neurotrophic keratopathy (NK) using Keratograph 5M (K5M) and anterior segment OCT (AS-OCT), corneal healing was monitored with Keratograph 5M (Oculus, Wetzlar, Germany) and AS-OCT (DRI, Triton, Topcon, Tokyo, Japan) in 13 patients (8F and 5M), aged from 24 to 93 years (67.8 +/- 19) with severe NK, who were treated with Cenegermin 0.002% (20 mu g/mL) (Oxervate(R), Dompe, Farmaceutici Spa, Milan, Italy). The surface defects were evaluated on Keratograph 5M with ImageJ software and the corneal thickness variations were measured using DRI-Triton OCT software. Instrumental procedures were performed at baseline, and after 4 and 8 weeks of the treatment, respectively. The main outcome measures were reduction of the ulcers' area and corneal thickness recovery. The mean area of the corneal ulcers was reduced between baseline and 4 weeks examination in all patients, and at 8 weeks all ulcers were completely healed. An increase of the corneal thickness was evidenced between the baseline visit and after the 4- and 8-week follow-up, respectively. Additionally, only in collaborating subjects the In Vivo Confocal Microscopy (IVCM) was performed with HRT Rostock Cornea Module (Heidelberg Eng GmbH) to study the corneal nerves fibres. High-tech diagnostics with K5M, AS-OCT and IVCM proved useful in the assessment of corneal morphology and the healing process in patients with NK and could be extended to assess other corneal pathologies.
引用
收藏
页数:9
相关论文
共 42 条
  • [41] The role of wearable devices and objective gait analysis for the assessment and monitoring of patients with lumbar spinal stenosis: systematic review
    Chakravorty, Ananya
    Mobbs, Ralph J.
    Anderson, David B.
    Rooke, Kaitlin
    Phan, Kevin
    Yoong, Nicole
    Maharaj, Monish
    Choy, Wen Jie
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [42] The role of wearable devices and objective gait analysis for the assessment and monitoring of patients with lumbar spinal stenosis: systematic review
    Ananya Chakravorty
    Ralph J. Mobbs
    David B. Anderson
    Kaitlin Rooke
    Kevin Phan
    Nicole Yoong
    Monish Maharaj
    Wen Jie Choy
    BMC Musculoskeletal Disorders, 20