Preliminary study on ECT imaging of flames in porous media

被引:44
作者
Liu, S. [1 ]
Chen, Q. [2 ]
Xiong, X. [3 ]
Zhang, Z. [3 ]
Lei, J. [1 ]
机构
[1] N China Elect Power Univ, Minist Educ, Key Lab Condit Monitoring & Control Power Plant E, Beijing 102206, Peoples R China
[2] Beijing Jiaotong Univ, Sch Mech & Elect Control, Beijing 10044, Peoples R China
[3] Natl Nat Sci Fdn China, Beijing 100044, Peoples R China
关键词
ECT; porous media; combustion visualization;
D O I
10.1088/0957-0233/19/9/094017
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This preliminary study for the first time investigated the feasibility of tomographic monitoring of flames in porous media, in which the cross-sectional profiles of flames inside a porous medium were imaged by electrical capacitance tomography (ECT). The relationship between the flame ionization and relative permittivity was established as the basis for ECT imaging of flames. Image reconstruction algorithms were discussed and an online iterative method OIOR was selected for image reconstruction. Experimental measurements were carried out and images of the flames were reconstructed. The shape, size and motion of the flames in a porous block were clearly monitored. Also the images correspond clearly to the variations of the combustion intensity. The feasibility of ECT monitoring of flames in porous media is proven by this study.
引用
收藏
页数:7
相关论文
共 28 条
  • [1] AUZINS J, 1995, EL ENG CONTR SESS SP
  • [2] CALCOTTE HF, 1962, 9TH S INT COMB, P622
  • [3] Simultaneous measurement of three-dimensional flame contour and velocity field for characterizing the flickering motion of a dilute hydrogen flame
    Fujisawa, N.
    Nakashima, K.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (07) : 2103 - 2110
  • [4] Green J. A., 1962, 9 INT S COMB, P607
  • [5] ENGINE FLAME IMAGING USING ELECTRICAL CAPACITANCE TOMOGRAPHY
    HE, R
    XIE, CG
    WATERFALL, RC
    BECK, MS
    BECK, CM
    [J]. ELECTRONICS LETTERS, 1994, 30 (07) : 559 - 560
  • [6] Landweber L., 1951, AM J MATH, V73, P615
  • [7] An image reconstruction algorithm based on new objective functional for electrical capacitance tomography
    Lei, Jing
    Liu, Shi
    Li, Zhihong
    Schlaberg, H. Inaki
    Sun, Meng
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (01)
  • [8] Prior-online iteration for image reconstruction with electrical capacitance tomography
    Liu, S
    Fu, L
    Yang, WQ
    Wang, HG
    Jiang, F
    [J]. IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2004, 151 (03) : 195 - 200
  • [9] Liu S, 2003, P 3 WORLD C IND PROC, P403
  • [10] A nonlinear image reconstruction technique for ECT using a combined neural network approach
    Marashdeh, Q.
    Warsito, W.
    Fan, L-S
    Teixeira, F. L.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (08) : 2097 - 2103