A large-stroke shape memory alloy spring actuator using double-coil configuration

被引:17
作者
Kim, Seung-Won [1 ]
Lee, Jong-Gu [2 ]
An, Sungmin [1 ]
Cho, Maenghyo [2 ]
Cho, Kyu-Jin [1 ]
机构
[1] Seoul Natl Univ, Dept Mech & Aerosp Engn IAMD, Biorobot Lab, Seoul 151742, South Korea
[2] Seoul Natl Univ, Dept Mech & Aerosp Engn IAMD, Smart Struct & Design Lab, Seoul 151742, South Korea
基金
新加坡国家研究基金会;
关键词
shape memory alloy (SMA); large actuation stroke; double coil; spring; actuator; ROBOT;
D O I
10.1088/0964-1726/24/9/095014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One way to increase the range of motion of shape memory alloy (SMA) actuators is to create displacements of the SMA associated with not only the deformation from straining but also rigid-body motion from translation and rotation. Rigid-body motion allows the SMA to create larger displacements without exceeding the maximum recovery strain so that the SMA actuators can have a larger shape recovery ratio. To improve the linear actuation stroke of SMA wire actuators, a novel SMA spring actuator is proposed that employs a double-coil geometry that allows the displacement of the SMA to be mainly induced by rigid-body motion. A double-coil SMA spring actuator is fabricated by coiling an SMA wire twice so that the double coiling results in a reduction of the initial length of the double-coil SMA spring actuator. The effects of the geometric parameters on the actuation characteristic of a double-coil SMA spring actuator are verified numerically by finite element analysis and experimentally according to a parametric study of the geometric parameters. The displacement-to-force profile of the double-coil SMA spring actuator is nonlinear, and the spring stiffness changes when the actuator transforms its configuration from a double-coil shape to a single-coil shape. According to the results of the parametric study, increasing the wire diameter increases both primary and secondary coil stiffness, and increasing the primary inner coil diameter decreases both primary and secondary coil stiffness, whereas increasing the secondary inner coil diameter decreases only the secondary coil stiffness. The result shows that one of the double-coil SMA spring actuators with an initial length of 8 mm has a recovery ratio of 1250%, while the recovery ratio of the single-coil SMA spring actuator with the same geometric parameters is 432%.
引用
收藏
页数:21
相关论文
共 33 条
[1]   Wireless Displacement Sensing of Micromachined Spiral-Coil Actuator Using Resonant Frequency Tracking [J].
Ali, Mohamed Sultan Mohamed ;
AbuZaiter, Alaa ;
Schlosser, Colin ;
Bycraft, Brad ;
Takahata, Kenichi .
SENSORS, 2014, 14 (07) :12399-12409
[2]   Engineering design framework for a shape memory alloy coil spring actuator using a static two-state model [J].
An, Sung-Min ;
Ryu, Junghyun ;
Cho, Maenghyo ;
Cho, Kyu-Jin .
SMART MATERIALS AND STRUCTURES, 2012, 21 (05)
[3]   Modelisation of thermoelastic linear behaviour of tungsten filaments in simple and twin helical spring configurations [J].
Benghanem, N. ;
Kaoua, S. ;
Becheur, A. ;
Azzaz, M. .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2007, 44 (25-26) :8159-8176
[4]   Shape Memory Alloy Based Morphing Aerostructures [J].
Calkins, Frederick T. ;
Mabe, James H. .
JOURNAL OF MECHANICAL DESIGN, 2010, 132 (11)
[5]   An overview of nitinol medical applications [J].
Duerig, T ;
Pelton, A ;
Stöckel, D .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1999, 273 :149-160
[6]   A general method for the design and fabrication of shape memory alloy active spring actuators [J].
Follador, M. ;
Cianchetti, M. ;
Arienti, A. ;
Laschi, C. .
SMART MATERIALS AND STRUCTURES, 2012, 21 (11)
[7]   A shape memory alloy based tendon-driven actuation system for biomimetic artificial fingers, part II: modelling and control [J].
Gilardi, Gabriele ;
Haslam, Edmund ;
Bundhoo, Vishalini ;
Park, Edward J. .
ROBOTICA, 2010, 28 :675-687
[8]   Supercoiling in DNA and chromatin [J].
Gilbert, Nick ;
Allan, James .
CURRENT OPINION IN GENETICS & DEVELOPMENT, 2014, 25 :15-21
[9]   Double-helix coil for occlusion of large patent ductus arteriosus: Evaluation in a chronic lamb model [J].
Grabitz, RG ;
Freudenthal, F ;
Sigler, M ;
Le, TP ;
Boosfeld, C ;
Handt, S ;
von Bernuth, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) :677-683
[10]   Toward a Meso-Scale SMA-Actuated MRI-Compatible Neurosurgical Robot [J].
Ho, Mingyen ;
McMillan, Alan B. ;
Simard, J. Marc ;
Gullapalli, Rao ;
Desai, Jaydev P. .
IEEE TRANSACTIONS ON ROBOTICS, 2012, 28 (01) :213-222