Influence of electro-osmosis activation time on vacuum electro-osmosis consolidation of a dredged slurry

被引:65
|
作者
Wang, Jun [1 ]
Fu, Hongtao [1 ]
Liu, Feiyu [2 ]
Cai, Yuanqiang [1 ,3 ]
Zhou, Jie [2 ]
机构
[1] Wenzhou Univ, Coll Architecture & Civil Engn, Innovat Ctr Tideland Reclamat & Ecol Protect, Key Lab Engn & Technol Soft Soil Fdn & Tideland R, Wenzhou 325035, Peoples R China
[2] Shanghai Univ, Dept Civil Engn, 99 Shangda Rd, Shanghai 200072, Peoples R China
[3] Zhejiang Univ, Key Lab Soft Soils & Geoenvironm Engn, Minist Educ, Hangzhou 310058, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
electro-osmosis; vacuum preloading; dredged slurry; degree of consolidation; SILTY CLAY; IMPROVEMENT; SOIL; ELECTROOSMOSIS; COMBINATION;
D O I
10.1139/cgj-2016-0687
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Combining vacuum preloading with electro-osmosis of a dredged slurry is a significantly effective technology for ground improvement. Despite extensive research, the mechanism of vacuum preloading combined with electro-osmosis is still not properly understood, especially regarding the optimum electro-osmosis activation time. In this study, laboratory tests were performed to confirm the influence of electro-osmosis activation time on vacuum electro-osmosis consolidation of a dredged slurry. A total voltage of 12 V was used in five tests with different electro-osmosis activation times. During the combined process of vacuum preloading and electro-osmosis, the vacuum pressure, electric current, and volume of extracted water were monitored. The water content and shear strength were measured after the tests. The results indicated that electro-osmosis was activated when the degree of consolidation for the soil reached 60%. Thus, this approach can significantly promote the effectiveness of soil consolidation. The shear strength distribution along the depth was much more uniform in all tests with electro-osmosis. The shear strength decreased linearly with increasing distance from the anode rows, but sharp increases occurred near the cathode row (or prefabricated vertical drains).
引用
收藏
页码:147 / 153
页数:7
相关论文
共 50 条
  • [21] The two-dimensional consolidation theory of electro-osmosis
    Su, JQ
    Wang, Z
    GEOTECHNIQUE, 2003, 53 (08): : 759 - 763
  • [22] Electrothermal ac electro-osmosis
    Gagnon, Zachary R.
    Chang, Hsueh-Chia
    APPLIED PHYSICS LETTERS, 2009, 94 (02)
  • [23] Vacuum filter and direct current electro-osmosis dewatering of fine coal slurry
    Dong Xian-shu
    Hu Xiao-jie
    Yao Su-ling
    Ren Wei-peng
    Wang Zhi-zhong
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MINING SCIENCE & TECHNOLOGY (ICMST2009), 2009, 1 (01): : 685 - 693
  • [24] Experimental studies on vacuum preloading incorporated with electro-osmosis consolidation for dredger fill
    Sun Z.-H.
    Yu X.-J.
    Gao M.-J.
    Wu K.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2017, 39 (02): : 250 - 258
  • [25] Soil Improvement by Electro-osmosis with Vacuum Drainage in Cathode
    Liu, Zhi-ming
    Yang, Jian-gui
    Li, Qi-meng
    ELECTRONIC JOURNAL OF GEOTECHNICAL ENGINEERING, 2016, 21 (15): : 1 - 13
  • [26] Mobilisation of bacteria in soils by electro-osmosis
    Suni, S
    Romantschuk, M
    FEMS MICROBIOLOGY ECOLOGY, 2004, 49 (01) : 51 - 57
  • [27] TRANSIENT ELECTRO-OSMOSIS IN CAPILLARY TUBES
    HANNA, WT
    OSTERLE, JF
    JOURNAL OF CHEMICAL PHYSICS, 1968, 49 (09): : 4062 - &
  • [28] INDUCED ELECTRO-OSMOSIS IN ROOT TISSUES
    FENSOM, DS
    MEYLAN, S
    PILET, PE
    CANADIAN JOURNAL OF BOTANY, 1965, 43 (04): : 453 - +
  • [29] THE PHENOMENOLOGY OF ELECTRO-OSMOSIS AND STREAMING POTENTIAL
    LORENZ, PB
    JOURNAL OF PHYSICAL CHEMISTRY, 1952, 56 (06): : 775 - 778
  • [30] Electro-osmosis in nematic liquid crystals
    Tovkach, O. M.
    Calderer, M. Carme
    Golovaty, Dmitry
    Lavrentovich, Oleg
    Walkington, Noel J.
    PHYSICAL REVIEW E, 2016, 94 (01)