Shoulder Function After Cardioverter-Defibrillator Implantation: 5-Year Follow-up

被引:10
作者
Martignani, Cristian [1 ]
Massaro, Giulia [1 ]
Mazzotti, Andrea [1 ]
Pegreffi, Francesco [2 ]
Ziacchi, Matteo [1 ]
Biffi, Mauro [1 ]
Porcellini, Giuseppe [3 ]
Boriani, Giuseppe [4 ]
Diemberger, Igor [1 ]
机构
[1] Univ Bologna, Policlin S Orsola Malpighi Hosp, Inst Cardiol, Dept Expt Diagnost & Special Med, Via Massarenti 9, I-40138 Bologna, Italy
[2] Univ Bologna, Inst Sport Med, Bologna, Italy
[3] Cattolica Univ, D Cervesi Hosp, Unit Shoulder & Elbow Surg, Cattolica, Italy
[4] Univ Modena & Reggio Emilia, Modena Univ Hosp, Cardiovasc Div, Modena, Italy
关键词
QUALITY-OF-LIFE; LEAD MANAGEMENT; ESC GUIDELINES; PACEMAKER; EXTRACTION; EXPERIENCE;
D O I
10.1016/j.athoracsur.2019.10.063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Implantable cardioverter-defibrillator (ICD) represents the main tool for prevention of sudden cardiac death. Different kinds of postimplant complications have been described; however, little is known about shoulder functional impairment and its impact on quality of life. Methods. Patients with standard indications for elective prepectoral subcutaneous ICD insertion were enrolled during a 1-year period. The impact of ICD implantation on shoulder motility, pain, general disability, and quality of life was evaluated prospectively at baseline, and after 2 weeks, 3 months, 1 year, and 5 years using the Constant score, the Numeric Pain Rating Scale, the Disabilities of the Arm, Shoulder, and Hand scale, and the Short Form-36 Health Survey questionnaire. Results. A total of 50 patients underwent insertion of single, dual chamber, or biventricular ICDs. Two weeks after implantation, functional impairment and mild pain were observed in ipsilateral shoulder movements, with a reduction in the Short Form-36 Health Survey score. Shoulder functional impairment improved at the thirdmonth evaluations, with almost normalization at 1-year and 5-year assessments, as well as pain and quality of life. Conclusions. Prepectoral subcutaneous ICD implantation may be associated with ipsilateral shoulder functional impairment that regresses partially after 3 months and completely at 1-year and 5-year assessments. The less invasive implantation technique and the relatively small size of modern ICDs, independently from types and volumes, may be relevant to the degree of post-implantation shoulder functional impairment and recovery time. Shoulder function should be assessed at routine checks, especially soon after ICD implantation because of potential functional impairment and subsequent impact on quality of life. (C) 2020 by The Society of Thoracic Surgeons.
引用
收藏
页码:608 / 614
页数:7
相关论文
共 30 条
  • [1] BLOCK M, 1994, HERZ, V19, P259
  • [2] Bolton JE, 1998, J MANIP PHYSIOL THER, V21, P1
  • [3] Outcome of cardioverter-defibrillator implant in patients with arrhythmogenic right ventricular cardiomyopathy
    Boriani, Giuseppe
    Artale, Paolo
    Biffi, Mauro
    Martignani, Cristian
    Frabetti, Lorenzo
    Valzania, Cinzia
    Diemberger, Igor
    Ziacchi, Matteo
    Bertini, Matteo
    Rapezzi, Claudio
    Parlapiano, Mario
    Branzi, Angelo
    [J]. HEART AND VESSELS, 2007, 22 (03) : 184 - 192
  • [4] Boriani Giuseppe, 2014, Indian Heart J, V66 Suppl 1, pS101, DOI 10.1016/j.ihj.2013.12.034
  • [5] Assessment of pain
    Breivik, H.
    Borchgrevink, P. C.
    Allen, S. M.
    Rosseland, L. A.
    Romundstad, L.
    Hals, E. K. Breivik
    Kvarstein, G.
    Stubhaug, A.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (01) : 17 - 24
  • [6] Frozen shoulder syndrome associated with subpectoral defibrillator implantation
    Burke, MC
    Drinan, K
    Kopp, DE
    Kall, JG
    Verdino, RJ
    Paydak, H
    Wilber, DJ
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1999, 3 (03) : 253 - 256
  • [7] A review of the Constant score: Modifications and guidelines for its use
    Constant, Christopher R.
    Gerber, Christian
    Emery, Rogerj. H.
    Solbjerg, Jens Ole
    Boileau, Pascal
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (02) : 355 - 361
  • [8] CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
  • [9] A comparative review of generic quality-of-life instruments
    Coons, SJ
    Rao, S
    Keininger, DL
    Hays, RD
    [J]. PHARMACOECONOMICS, 2000, 17 (01) : 13 - 35
  • [10] Implantation of cardioverter-defibrillator: Effects on shoulder function
    Diemberger, Igor
    Pegreffi, Francesco
    Mazzotti, Andrea
    Foschi, Elia
    Martignani, Cristian
    Belli, Guido
    Biffi, Mauro
    Ziacchi, Matteo
    Branzi, Angelo
    Grigioni, Francesco
    Latessa, Pasqualino Maietta
    Porcellini, Giuseppe
    Tentoni, Claudio
    Boriani, Giuseppe
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (01) : 294 - 299