A single-band cold mass support system for MICE superconducting coupling magnet

被引:0
|
作者
Wu, H. [1 ]
Wang, L. [1 ]
Liu, X. K. [1 ]
Liu, C. S. [1 ]
Li, L. K. [1 ]
Xu, F. Y. [1 ]
Jia, L. X. [1 ]
Green, M. A.
机构
[1] Harbin Inst Technol, Inst Cryogen & Superconduct Technol, Harbin 150001, Peoples R China
来源
CRYOGENICS AND REFRIGERATION, PROCEEDINGS | 2008年
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The cooling channel of the Muon Ionization Cooling Experiment (MICE) consists of eighteen superconducting solenoid coils, which are magnetically hooked together and contained in seven modules. The operations of a pair of MICE superconducting coupling magnets are affected directly by the other solenoid coils in the MICE channel. In order to meet the stringent requirement for the magnet center and axis azimuthal angle at 4.2K, a self-centered tension-band cold mass support system with intermediate thermal interruption was applied for the MICE superconducting coupling magnet. The physical center of the magnet does not change as it is cooled down from 300K to 4.2K using this support system. This paper analyzed and calculated force loads on the coupling magnet under various operation modes of the MICE cooling channel. The performance parameters of a single-band cold mass support system were calculated also.
引用
收藏
页码:351 / 354
页数:4
相关论文
共 50 条
  • [1] STRUCTURAL DESIGN AND ANALYSIS FOR A DOUBLE-BAND COLD MASS SUPPORT OF MICE COUPLING MAGNET
    Wu, H.
    Liu, X. K.
    Wang, L.
    Li, S. Y.
    Guo, X. L.
    Pan, H.
    Xu, F. Y.
    Green, M. A.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 997 - +
  • [2] Design and Analysis of a Self-Centered Cold Mass Support for the MICE Coupling Magnet
    Wang, L.
    Wu, H.
    Li, S. Y.
    Guo, X. L.
    Pan, H.
    Zheng, S. X.
    Green, M. A.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 2259 - 2262
  • [3] Cold Mass Support System for the MSU Superconducting Cyclotron Gas-Stopper Magnet
    Green, M. A.
    Ottarson, J.
    Bollen, G.
    Chouhan, S. S.
    DeKamp, J.
    Lawton, D.
    Magsig, C.
    Morrissey, D.
    Schwarz, S.
    Zeller, A. F.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (04)
  • [4] The helium cooling system and cold mass support system for the MICE coupling solenoid
    Wang, L.
    Wu, H.
    Li, L. K.
    Green, M. A.
    Liu, C. S.
    Li, S. Y.
    Liu, X. K.
    Jia, L. X.
    Virostek, S. P.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 941 - 944
  • [5] Cold Mass Support Structure Design of MRI Superconducting Magnet Developed by IHEP
    Zhang, Kai
    Zhu, Zian
    Zhao, Ling
    Hou, Zhilong
    Wang, Meifen
    Zhang, Guoqing
    Yao, Weichao
    Ning, Feipeng
    Wang, Zhoujie
    Zhang, Xiaotao
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (02)
  • [6] Evolution of the Design of Cold Mass Support for the ITER Magnet Feeder System
    陆坤
    宋云涛
    牛二武
    周挺志
    王忠伟
    陈永华
    朱银峰
    Plasma Science and Technology, 2013, 15 (02) : 196 - 200
  • [7] Evolution of the Design of Cold Mass Support for the ITER Magnet Feeder System
    Lu Kun
    Song Yuntao
    Niu Erwu
    Zhou Tinzhi
    Wang Zhongwei
    Chen Yonghua
    Zhu Yinfeng
    PLASMA SCIENCE & TECHNOLOGY, 2013, 15 (02) : 196 - 200
  • [8] Evolution of the Design of Cold Mass Support for the ITER Magnet Feeder System
    陆坤
    宋云涛
    牛二武
    周挺志
    王忠伟
    陈永华
    朱银峰
    Plasma Science and Technology, 2013, (02) : 196 - 200
  • [9] On the accuracy of single-band mapping of the emery model and feasibility of superconducting pairing
    Ovchinnikov, A.A.
    Ovchinnikova, M.Ya.
    Chemical Physics Reports, 1996, 15 (09): : 1351 - 1360
  • [10] MAGNETISM IN THE SINGLE-BAND AND 2-BAND HUBBARD MODELS - GENERALIZED HUNDS COUPLING
    KUSAKABE, K
    AOKI, H
    PHYSICA C, 1991, 185 : 1505 - 1506