Multi-channel Magnetic Induction Tomography Measurement System

被引:4
|
作者
He, Wei [1 ]
Luo, Haijun [1 ]
Xu, Zheng [1 ]
Wang, Junfeng [1 ]
机构
[1] Chongqing Univ, Elect Engn Coll, Chongqing 400044, Peoples R China
关键词
magnetic induction tomography(MIT); biological tissue; multi-channel measurement system; human brain model;
D O I
10.1109/BMEI.2010.5639540
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic induction tomography(MIT) is a noninvasive and contactless medical imaging technique. The 16 channels of MIT system is showed in the paper, which image for the low conductivity object with working at 1MHz. In the study, we use the water tanker filled with salt solution and the different conductivity agar blocks to simulate the human brain with edema or hematoma. The each sensor is composed of the excitation coil, the two detection coils, a preamplifier board and a power amplifier board, which were fixed by four plastic columns. This paper researches the sensitivity and stability of single sensor unit, and the phase sensitivity of the system is 0.29 degrees/S.m(-1) and the phase drift is in the range of -0.02 degrees to +0.06 degrees over 30 minutes. Finally, the 2-dimensional images of conductivity distribution are obtained using the inverse distance weighted spatial interpolation algorithm of and the direct projection way.
引用
收藏
页码:402 / 405
页数:4
相关论文
共 50 条
  • [41] Quick measurement of signal frequency in multi-channel
    Lin, H
    Wang, J
    Huang, YQ
    Hu, TL
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 1, 2005, : 116 - 119
  • [42] Multi-channel SQUID systems for biomagnetic measurement
    Uehara, G
    Adachi, Y
    Kawai, J
    Shimogawara, M
    Higuchi, M
    Haruta, Y
    Ogata, H
    Kado, H
    IEICE TRANSACTIONS ON ELECTRONICS, 2003, E86C (01) : 43 - 54
  • [43] 16 channel magnetic induction tomography system featuring parallel readout
    Hamsch, M.
    Igney, C. H.
    Vauhkonen, M.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 484 - 487
  • [44] Application of multi-channel counter in nuclear measurement
    Cao, Bin
    Yi, Jing-Bing
    Cai, Zhi-Quan
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 2002, 22 (01):
  • [45] Multi-channel magnetocardiogardiography system calibration
    Zhang Yong-Sheng
    Qiu Yang
    Zhang Chao-Xiang
    Li Hua
    Zhang Shu-Lin
    Wang Yong-Liang
    Xu Xiao-Feng
    Ding Hong-Sheng
    Kong Xiang-Yan
    ACTA PHYSICA SINICA, 2014, 63 (22)
  • [46] On a Multi-Channel Retrial Queueing System
    Pryshchepa O.V.
    Lebedev E.O.
    Cybernetics and Systems Analysis, 2017, 53 (03) : 441 - 449
  • [47] Priority users in a multi-channel system
    Burrell, Anthony
    Papantoni-Kazakos, P.
    2006 40TH ANNUAL CONFERENCE ON INFORMATION SCIENCES AND SYSTEMS, VOLS 1-4, 2006, : 1218 - 1223
  • [48] A multi-channel multifocal VECP system
    Chisholm, JA
    Parks, S
    Keating, D
    Evans, AL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U1338 - U1338
  • [49] MULTI-CHANNEL SYSTEM OF RADIOECOLOGICAL CONTROL
    Prokhorovich, Valuev Nikolay
    Arsenievich, Mashintsov Evgeniy
    Maksimovich, Yudanov Petr
    PROCEEDINGS OF THE TULA STATES UNIVERSITY-SCIENCES OF EARTH, 2022, 1 : 39 - 51
  • [50] IMPLANTABLE MULTI-CHANNEL BIOTELEMETRY SYSTEM
    PAULEY, JD
    REITE, M
    WALKER, SD
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1974, 37 (02): : 153 - 160