Multi-channel Magnetic Induction Tomography Measurement System

被引:4
|
作者
He, Wei [1 ]
Luo, Haijun [1 ]
Xu, Zheng [1 ]
Wang, Junfeng [1 ]
机构
[1] Chongqing Univ, Elect Engn Coll, Chongqing 400044, Peoples R China
关键词
magnetic induction tomography(MIT); biological tissue; multi-channel measurement system; human brain model;
D O I
10.1109/BMEI.2010.5639540
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic induction tomography(MIT) is a noninvasive and contactless medical imaging technique. The 16 channels of MIT system is showed in the paper, which image for the low conductivity object with working at 1MHz. In the study, we use the water tanker filled with salt solution and the different conductivity agar blocks to simulate the human brain with edema or hematoma. The each sensor is composed of the excitation coil, the two detection coils, a preamplifier board and a power amplifier board, which were fixed by four plastic columns. This paper researches the sensitivity and stability of single sensor unit, and the phase sensitivity of the system is 0.29 degrees/S.m(-1) and the phase drift is in the range of -0.02 degrees to +0.06 degrees over 30 minutes. Finally, the 2-dimensional images of conductivity distribution are obtained using the inverse distance weighted spatial interpolation algorithm of and the direct projection way.
引用
收藏
页码:402 / 405
页数:4
相关论文
共 50 条
  • [21] Multi-Channel Optoelectronic Measurement System for Soil Nutrients Analysis
    Ma, Liuzheng
    Li, Zhenfeng
    Birech, Zephania
    Li, Shixin
    Yang, Yatao
    Zhang, Wei
    Hu, Jiandong
    ELECTRONICS, 2019, 8 (04):
  • [22] Measurement System of Biological Tissue Magnetic Induction Tomography
    Xu, Zheng
    He, Wei
    He, Chuanhong
    Zhang, Zanlong
    Liu, Zinan
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1844 - 1847
  • [23] Multi-Channel Time Domain Spectroscopic Optical Coherence Tomography System
    Meadway, Alexander
    Darbrazi, Seyed Hamid Hosseiny
    Cernat, Ramona
    Dobre, George
    Podoleanu, Adrian Gh
    Rosen, Richard B.
    1ST CANTERBURY WORKSHOP ON OPTICAL COHERENCE TOMOGRAPHY AND ADAPTIVE OPTICS, 2008, 7139
  • [24] MOTION MEASUREMENT WITH A MULTI-CHANNEL SAR
    Jansen, Robert W.
    Sletten, Mark A.
    2014 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2014, : 5219 - 5221
  • [25] Multi-channel measurement of transmissivity of smoke
    Shen, Tao
    Song, Jian-she
    INTELLIGENT CONTROL AND AUTOMATION, 2006, 344 : 554 - 558
  • [26] MULTI-CHANNEL VIBRATION MEASUREMENT MACHINE
    Golushko, D. A.
    Lysenko, A. V.
    Yurkov, N. K.
    Bushmelev, P. E.
    Kalaev, M. P.
    2016 INTERNATIONAL CONFERENCE ON ACTUAL PROBLEMS OF ELECTRON DEVICES ENGINEERING (APEDE), VOL 2, 2016, : 292 - +
  • [27] MULTI-CHANNEL OSCILLOSCOPE SYSTEM
    AMATO, G
    CHESI, E
    LAMBERT, JC
    NUCLEAR INSTRUMENTS & METHODS, 1963, 20 (JAN): : 341 - 341
  • [28] Multi-Channel Chaotic System
    Voliansky, Roman
    Kluev, Oleg
    Shramko, Iurii
    Kuznetsov, Vitaliy
    Volianska, Nina
    2020 10TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTER INFORMATION TECHNOLOGIES (ACIT), 2020, : 196 - 199
  • [29] FPGA-PLC-based multi-channel position measurement system
    Patel, Dhruv M.
    Shah, Ankit K.
    ISA TRANSACTIONS, 2021, 115 : 234 - 249
  • [30] Evaluation of a multi-channel EEG: (Electroencephalogram) measurement electrode system.
    Fukuzumi, S
    Yamazaki, T
    Kamijo, K
    Shiozawa, H
    Kuroiwa, Y
    NEC RESEARCH & DEVELOPMENT, 1998, 39 (04): : 522 - 527