Experimental investigation of a two-phase closed thermosyphon charged with hydrocarbon and Freon refrigerants

被引:36
作者
Ma, Limin [1 ]
Shang, Linlin
Zhong, Dan
Ji, Zhongli
机构
[1] China Univ Petr, 18th Fuxue Rd Changping Dist, Beijing 102249, Peoples R China
关键词
Two-phase closed thermosyphon; Performance evaluation; Working fluid; Heat transfer coefficient; SOLAR WATER-HEATER; PERFORMANCE EVALUATION; COLLECTOR; R134A; OPTIMIZATION; WORKING; FLUIDS; R600A; R152A; PHASE;
D O I
10.1016/j.apenergy.2017.06.100
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Two-phase closed thermosyphons (TPCTs) are simple, efficient, and low cost heat exchangers. They have been explored for use in the renewable energy resource utilization marker and low grade thermal energy heat recovery systems. Freon R134a has been extensively used in refrigeration systems and researched as a working fluid of TPCTs; however; it has high global warming potential and operating pressure. In this paper, an experimental investigation of the performance of TPCTs charged with eight working fluids: R134a, R601, R245fa, R600a, R1234ze, R152a, R245fa/R152a, and R601/R245fa have been carried out. The experimental results showed that R245fa/R152a offered the best performance in maximum heat transfer rate. R134a outperformed the other pure working fluids, while R600a and R1234ze had close performances to that of R134a. R245fa showed marginal improvement at higher operating temperatures. The predictions of six evaporation heat transfer coefficients (HTCs) correlations, including Imura, Shiraishi, Labuntsov, Kutateladze, Cooper, and Rohsenow were compared with the experimental results. In the five constant coefficients and powers correlations, the Shiraishi and Cooper correlations had superior accuracy. The coefficients and powers of the Rohsenow correlations fitted based on the experimental data, while they had the best accuracy. Nusselt and Hashimoto-Kaminaga correlations were chosen to predict the condensation HTCs. Both of them tend to over-predict the condensation HTCs in low heat fluxes while under-predicting in high heat fluxes. The experimental results had greater agreement with Hashimoto and Kaminaga correlations. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:665 / 673
页数:9
相关论文
共 43 条
[1]  
[Anonymous], 2016, SIMULATION EXPT VALI
[2]   Experimental comparison between R152a and R134a working in a refrigeration facility equipped with a hermetic compressor [J].
Cabello, R. ;
Sanchez, D. ;
Llopis, R. ;
Arauzo, I. ;
Torrella, E. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 :92-105
[3]   The geothermal convector: experimental and numerical results [J].
Carotenuto, A ;
Casarosa, C ;
Martorano, L .
APPLIED THERMAL ENGINEERING, 1999, 19 (04) :349-374
[4]   Performance study of heat-pipe solar photovoltaic/thermal heat pump system [J].
Chen, Hongbing ;
Zhang, Lei ;
Jie, Pengfei ;
Xiong, Yaxuan ;
Xu, Peng ;
Zhai, Huixing .
APPLIED ENERGY, 2017, 190 :960-980
[5]  
Cooper M. G., 1984, First U.K. National Conference on Heat Transfer, P785
[6]   FLOW BOILING - THE APPARENTLY NUCLEATE REGIME [J].
COOPER, MG .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1989, 32 (03) :459-464
[7]   EXPERIMENTAL-STUDY OF A SELF-PUMPING BOILING COLLECTOR SOLAR HOT WATER-SYSTEM [J].
DAVIDSON, JH ;
WALKER, HA ;
LOF, GOG .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1989, 111 (03) :211-218
[8]   DESIGN OPTIMIZATION OF A 2-PHASE SOLAR WATER-HEATER USING R-123 [J].
DAVIDSON, JH ;
WALKER, HA .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (01) :53-61
[9]   Performance evaluation of a refrigerant-charged integrated solar water heater in northern Nigeria [J].
Enaburekhan, Joseph ;
Yakasai, Usman Tanko .
DESALINATION, 2009, 243 (1-3) :208-217
[10]   Experimental investigation of a two-phase closed thermosyphon solar water heater [J].
Esen, M ;