Identification and quantification of 8 sulfonylureas with clinical toxicology interest by liquid chromatography-ion-trap tandem mass spectrometry and library searching

被引:38
作者
Hoizey, G
Lamiable, D
Trenque, T
Robinet, A
Binet, L
Kaltenbach, ML
Havet, S
Millart, H
机构
[1] CHU Reims, Hosp Maison Blanche, Lab Pharmacol & Toxicol, F-51092 Reims, France
[2] CHU Reims, Ctr Reg Pharmacovigilance, F-51092 Reims, France
[3] UFR Pharm, Lab Pharmacol & Pharmacocinet, Reims, France
关键词
D O I
10.1373/clinchem.2005.050864
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Identification of sulfonylureas in blood may be useful in the evaluation of hypoglycemic crises of unknown origin. The aim of the present study was to develop a highly selective liquid chromatography- electrospray tandem mass spectrometry (MS-MS) method using an ion-trap detector for rapid screening, identification, and quantification of sulfonylureas in human plasma. Methods: After standard liquid-liquid extraction with glisoxepide as an internal standard, 8 sulfonylureas (glibenclamide, glipizide, gliclazide, glibornuride, glimepiride, carbutamide, chlorpropamide, and tolbutamide) were eluted from a C-18 column within 10 min with an isocratic mobile phase. Drugs were identified and quantified in full-scan MS-MS mode by use of a homemade MS-MS library. We used the assay in 134 cases of hypoglycemic crises of unknown origin. Results: No ion suppression effect was noted for the analytes at their specific retention-time windows. For all drugs, assay validation showed good linearity (r(2) >0.990) and acceptable imprecision and recovery based on commonly used criteria of acceptance. The mean extraction recoveries were 63%-87% for 5 sulfonylureas but <45% for 3 (carbutamide, chlorpropamide, and tolbutamide). Nevertheless, the high sensitivity of the MS instrument made possible detection and quantification of all 8 drugs at subtherapeutic to toxic concentrations with good precision. Sulfonylureas were found in 9 hypoglycemic patients. Conclusion: The described assay method allows accurate, rapid identification and quantification of 8 sulfonylureas in human plasma and can be used for specific diagnosis of factitious hypoglycemia caused by ingestion of these drugs. (C) 2005 American Association for Clinical Chemistry.
引用
收藏
页码:1666 / 1672
页数:7
相关论文
共 14 条
[1]   DETERMINATION OF GLYBURIDE IN HUMAN-SERUM BY LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
ADAMS, WJ ;
SKINNER, GS ;
BOMBARDT, PA ;
COURTNEY, M ;
BREWER, JE .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1287-1291
[2]   Validation of liquid chromatographic and gas chromatographic methods - Applications to pharmacokinetics [J].
Bressolle, F ;
BrometPetit, M ;
Audran, M .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (01) :3-10
[3]  
Charlton R, 2001, DIABETOLOGIA, V44, P784
[4]  
COLE MJ, 2002, ELECTROSPRAY IONIZAT, P211
[5]   A CLASS-INDEPENDENT DRUG SCREEN IN FORENSIC TOXICOLOGY USING A PHOTODIODE-ARRAY DETECTOR [J].
DRUMMER, OH ;
KOTSOS, A ;
MCINTYRE, IM .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (04) :225-229
[6]   Identification of sulfonylureas in serum by electrospray mass spectrometry [J].
Magni, F ;
Marazzini, L ;
Pereira, S ;
Monti, L ;
Kienle, MG .
ANALYTICAL BIOCHEMISTRY, 2000, 282 (01) :136-141
[7]   Screening, library-assisted identification and validated quantification of oral antidiabetics of the sulfonylurea-type in plasma by atmospheric pressure chemical ionization liquid chromatography-mass spectrometry [J].
Maurer, HH ;
Kratzsch, C ;
Kraemer, T ;
Peters, FT ;
Weber, AA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01) :63-73
[8]   Ion suppression effects in liquid chromatography-electrospray-ionisation transport-region collision induced dissociation mass spectrometry with different serum extraction methods for systematic toxicological analysis with mass spectra libraries [J].
Müller, C ;
Schäfer, P ;
Störtzel, M ;
Vogt, S ;
Weinmann, W .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01) :47-52
[9]   DETECTION OF HYPOGLYCEMIC DRUGS IN HUMAN URINE USING MICELLAR ELECTROKINETIC CHROMATOGRAPHY [J].
NUNEZ, M ;
FERGUSON, JE ;
MACHACEK, D ;
JACOB, G ;
ODA, RP ;
LAWSON, GM ;
LANDERS, JP .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3668-3675
[10]  
Paroni R, 2000, CLIN CHEM, V46, P1773