Real-time reaction monitoring using ion mobility-mass spectrometry

被引:14
作者
Harry, Emma L. [1 ]
Bristow, Anthony W. T. [2 ]
Wilson, Ian D. [3 ]
Creaser, Colin S. [1 ]
机构
[1] Univ Loughborough, Dept Chem, Ctr Analyt Sci, Loughborough LE11 3TU, Leics, England
[2] AstraZeneca, Pharmaceut Dev, Macclesfield SK10 2NA, Cheshire, England
[3] AstraZeneca, Clin Pharmacol Drug Metab & Pharmacokinet Dept, Macclesfield SK10 4TG, Cheshire, England
关键词
D O I
10.1039/c0an00700e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potential of ion mobility (IM) spectrometry in combination with mass spectrometry (MS) for real-time reaction monitoring is reported. The combined IM-MS approach using electrospray ionization affords gas-phase analyte characterization based on both mass-to-charge (m/z) ratio and gas-phase ion mobility (drift time). The use of IM-MS analysis is demonstrated for the monitoring of the reaction products formed when 7-fluoro-6-hydroxy-2-methylindole is deprotonated by aqueous sodium hydroxide. Real-time reaction monitoring was carried out over a period of several hours, with the reaction mixture sampled and analysed at intervals of several minutes. Product ion relative intensity is enhanced selectively in the ion mobility-selected mass spectrum, compared to mass spectrometry alone. The combined IM-MS approach has potential as a rapid and selective technique to aid pharmaceutical process control and for the elucidation of reaction mechanism.
引用
收藏
页码:1728 / 1732
页数:5
相关论文
共 24 条
[1]  
[Anonymous], 2005, ION MOBILITY SPECTRO, DOI DOI 10.1201/9781420038972
[2]  
Bacon T., 2005, ACID HALOGEN GAS MON
[3]  
BAKEEV K, 2005, PROCESS ANAL TECHNOL, P159
[4]   Biomolecule Analysis by Ion Mobility Spectrometry [J].
Bohrer, Brian C. ;
Mererbloom, Samuel I. ;
Koeniger, Stormy L. ;
Hilderbrand, Amy E. ;
Clemmer, David E. .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2008, 1 (01) :293-327
[5]  
DEBONO R, 2002, PHARM BIOTECHNOL, V72, P78
[6]   ION MOBILITY SPECTROMETRY FOR CONTINUOUS ON-SITE MONITORING OF NICOTINE VAPORS IN AIR DURING THE MANUFACTURE OF TRANSDERMAL SYSTEMS [J].
EICEMAN, GA ;
SOWA, S ;
LIN, S ;
BELL, SE .
JOURNAL OF HAZARDOUS MATERIALS, 1995, 43 (1-2) :13-30
[7]   NEGATIVE-ION MOBILITY SPECTROMETRY FOR SELECTED INORGANIC POLLUTANT GASES AND GAS-MIXTURES IN AIR [J].
EICEMAN, GA ;
LEASURE, CS ;
VANDIVER, VJ .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :76-80
[8]   A method for direct measurement of ion mobilities using a travelling wave ion guide [J].
Giles, Kevin ;
Wildgoose, Jason L. ;
Langridge, David J. ;
Campuzano, Iain .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 298 (1-3) :10-16
[9]   Non-destructive real-time reaction monitoring in solid phase synthesis by near-infrared reflectance spectroscopy-esterification of a resin-bound alcohol [J].
Hammond, J ;
Kellam, B ;
Moffat, AC ;
Jee, RD .
ANALYTICAL COMMUNICATIONS, 1999, 36 (04) :127-129
[10]   An approach to enhancing coverage of the urinary metabonome using liquid chromatography-ion mobility-mass spectrometry [J].
Harry, Emma L. ;
Weston, Daniel J. ;
Bristow, Anthony W. T. ;
Wilson, Ian D. ;
Creaser, Colin S. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02) :357-361