Mobile phase influence on electrospray ionization for the analysis of smokeless powders by gradient reversed phase high-performance liquid chromatography-ESIMS

被引:11
作者
Mathis, JA [1 ]
McCord, BR [1 ]
机构
[1] Ohio Univ, Dept Chem & Biochem, Clippinger Labs, Athens, OH 45701 USA
关键词
forensic; electrospray ionization mass spectrometry; gradient; smokeless powders;
D O I
10.1016/j.forsciint.2004.10.008
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The solution parameters associated with gradient elution reversed phase high-performance liquid chromatography (HPLC) were characterized by evaluating the electrospray ionization mass spectrometry (ESIMS) response of selected smokeless powder additives. Using direct liquid infusion, the positive ion ESIMS responses were determined for three general classes of powder constituents: dialkylphthalate acid esters, N,N'-dialkyl-N,N'-diphenyl urea based stabilizers and nitroso-, nitro-, and dinitro- derivatives of diphenylamine. The relative ESIMS intensities of the powder components were investigated as a function of three solution parameters: ammonium acetate concentration, pH, and percent methanol. The effect of the ammonium acetate concentration demonstrates that the electrolyte is required for efficient ionization and the ESIMS intensity was optimal at a concentration of 2 mM for the selected compounds, except 2,4'-dinitrodiphenylamine. The aqueous solution pH, corresponding to the available protons in solution, did not have a significant effect on the ESIMS intensity of the analytes. The percent methanol was evaluated with both decreasing and constant electrolyte concentrations to demonstrate the effects of droplet stability and ion transfer into the gas phase. These findings were applied to the analysis of the selected smokeless powder additives using HPLC-ESIMS to illustrate increased sensitivity for the protonated molecules.(c) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 33 条
[1]   Determination of drug residues in water by the combination of liquid chromatography or capillary electrophoresis with electrospray mass spectrometry [J].
Ahrer, W ;
Scherwenk, E ;
Buchberger, W .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) :69-78
[2]   On the signal response of various pesticides in electrospray and atmospheric pressure chemical ionization depending on the flow-rate of eluent applied in liquid chromatography-tandem mass spectrometry [J].
Asperger, A ;
Efer, R ;
Koal, T ;
Engewald, W .
JOURNAL OF CHROMATOGRAPHY A, 2001, 937 (1-2) :65-72
[3]   Hyphenated liquid chromatographic techniques in forensic toxicology [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 733 (1-2) :65-91
[4]   Relating electrospray ionization response to nonpolar character of small peptides [J].
Cech, NB ;
Enke, CG .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2717-2723
[5]   Practical implications of some recent studies in electrospray ionization fundamentals [J].
Cech, NB ;
Enke, CG .
MASS SPECTROMETRY REVIEWS, 2001, 20 (06) :362-387
[6]   Predicting electrospray response from chromatographic retention time [J].
Cech, NB ;
Krone, JR ;
Enke, CG .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :208-213
[7]  
Cole RB, 2000, J MASS SPECTROM, V35, P763, DOI 10.1002/1096-9888(200007)35:7<763::AID-JMS16>3.3.CO
[8]  
2-R
[9]   Effects of salt concentration on analyte response using electrospray ionization mass spectrometry [J].
Constantopoulos, TL ;
Jackson, GS ;
Enke, CG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (07) :625-634
[10]   Influence of the eluent composition on the ionization efficiency for morphine of pneumatically assisted electrospray, atmospheric-pressure chemical ionization and sonic spray [J].
Dams, R ;
Benijts, T ;
Günther, W ;
Lambert, W ;
De Leenheer, A .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (11) :1072-1077