Reinforced-Concrete Shear Walls Retrofitted Using Weakening and Self-Centering: Numerical Modeling

被引:19
作者
Basereh, Sina [1 ]
Okumus, Pinar [1 ]
Aaleti, Sriram [2 ]
机构
[1] Univ Buffalo, Dept Civil Struct & Environm Engn, Buffalo, NY 14260 USA
[2] Univ Alabama, Dept Civil Construct & Environm Engn, Tuscaloosa, AL 35487 USA
基金
美国国家科学基金会;
关键词
Slender reinforced-concrete wall; Code-deficient; Cyclic loading; Numerical modeling; Retrofit; Weakening; Seismic; Post-tension; Shear failure; SEISMIC PERFORMANCE; STRUCTURAL WALLS; BRIDGE PIERS; BEHAVIOR; STRENGTH; LESSONS; DESIGN; TESTS;
D O I
10.1061/(ASCE)ST.1943-541X.0002669
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates a novel retrofit strategy for code-deficient reinforced-concrete (RC) shear walls that are vulnerable to undesirable failure modes. The strategy combines weakening by partially cutting the wall base and self-centering by adding post-tensioning. RC walls in need of retrofit were analyzed under lateral cyclic loading using three-dimensional (3D) finite element (FE) modeling. Analyses were validated using test data from the literature on conventional walls that failed in flexure/shear and pure shear. These analyses were used to study the retrofit strategy. A parametric study was conducted to determine the working details of the retrofit method. A method was proposed to select retrofit parameters preliminarily. Retrofitted and original walls were compared. The sequence in which wall components failed was documented to identify changes in failure modes. Results of the analyses showed that although retrofitting reduced energy dissipation capacity, flexural displacements increased due to retrofit of poorly designed RC walls suffering from partial or pure shear failure. Retrofit resulted in fewer cracks, less intense concrete crushing, and a delayed fracture of transverse reinforcement. (C) 2020 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 45 条
[21]  
Lee W., 2007, Proceedings of Structures Congress 2007, P1
[22]  
LEFAS ID, 1990, ACI STRUCT J, V87, P716
[23]  
Lombard J., 2000, PROCEEDING 12 WORLD, P1
[24]  
LSTC, 2017, LS DYNA KEYW US MAN
[25]   Quasi-static and pseudo-dynamic testing of unbonded post-tensioned rocking bridge piers with external replaceable dissipaters [J].
Marriott, Dion ;
Pampanin, Stefano ;
Palermo, Alessandro .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2009, 38 (03) :331-354
[26]   An overview of the PRESSS five-story precast test building [J].
Nakaki, SD ;
Stanton, JF ;
Sritharan, S .
PCI JOURNAL, 1999, 44 (02) :26-+
[27]   Seismic performance of segmental precast unbonded posttensioned concrete bridge columns [J].
Ou, Yu-Chen ;
Chiewanichakorn, Methee ;
Aref, Arnjad J. ;
Lee, George C. .
JOURNAL OF STRUCTURAL ENGINEERING, 2007, 133 (11) :1636-1647
[28]   Design, modeling, and experimental response of seismic resistant bridge piers with posttensioned dissipating connections [J].
Palermo, A. ;
Pampanin, S. ;
Marriott, D. .
JOURNAL OF STRUCTURAL ENGINEERING, 2007, 133 (11) :1648-1661
[29]  
Pampanin S, 2006, BULL N Z SOC EARTHQ, V39, P120
[30]   Seismic retrofit of shear walls with headed bars and carbon fiber wrap [J].
Paterson, J ;
Mitchell, D .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (05) :606-614