Diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity pulmonary lesions

被引:58
作者
Yamauchi, Yoshikane
Izumi, Yotaro [1 ]
Nakatsuka, Seishi [2 ]
Inoue, Masanori [2 ]
Hayashi, Yuichiro [3 ]
Mukai, Makio [3 ]
Nomori, Hiroaki
机构
[1] Keio Univ, Dept Surg, Sch Med, Div Gen Thorac Surg,Shinjuku Ku, Tokyo 1608582, Japan
[2] Keio Univ, Dept Diagnost Radiol, Sch Med, Tokyo 1608582, Japan
[3] Keio Univ, Div Diagnost Pathol, Sch Med, Tokyo 1608582, Japan
关键词
Lung cancer; Lung biopsy; Ground-glass opacity; ASPIRATION BIOPSY; CUTTING NEEDLE; IMPLANTATION; ACCURACY; NODULES; ADENOCARCINOMA; EXPERIENCE; CARCINOMA;
D O I
10.1016/j.ejrad.2011.03.088
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity (GGO) pulmonary lesions was evaluated. Materials and methods: Out of 90 patients who underwent CT fluoroscopy-guided core needle biopsy of GGO lesions at our institution, the biopsy results and the final diagnoses were retrospectively compared in 67 patients with available data (one lesion per patient). Diagnostic performance was also compared according to the lesion size (<= 10 mm (n = 8) versus 11-20 mm (n = 42) versus >20 mm (n = 17)), the percentage of GGO component (50-90% (n = 31) versus >90% (n = 36)), and the length of needle path (<7 cm (n = 45) versus >7 cm (n = 22)). Finally, all 90 cases were reviewed for complications. Results: The overall sensitivity, specificity, and accuracy were 97%, 100%, and 97%, respectively. The diagnostic sensitivity and accuracy tended to be lower in smaller lesions (<= 10 mm; 86 and 88%, 11-20 mm; 97 and 98%, >20 mm; 100 and 100%, respectively, p > 0.05), and in lesions with lower percentage of GGO component (50-90%; 93 and 94%, >90%; 100 and 100%, respectively, p = 0.21), but statistical significances were not reached. The sensitivity and accuracy were not significantly affected by the length of needle path (<= 7 cm; 98 and 98%, >7 cm; 95 and 96%, respectively, p = 1.00). Fourteen patients (16%) developed pneumothoraces, and 13 patients (14%) experienced mild hemoptysis, all of which resolved conservatively. Conclusion: The diagnostic performance was satisfactory, and it was considered that the procedure was appropriate for GGO lesions regardless of lesion size, the percentage of GGO component, or the length of needle path. The procedure was also feasible without any major complications. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E85 / E89
页数:5
相关论文
共 27 条
[1]   Minimally invasive approach to early, peripheral adenocarcinoma with ground-glass opacity appearance [J].
Asamura, Hisao .
ANNALS OF THORACIC SURGERY, 2008, 85 (02) :S701-S704
[2]   Ground-glass opacity at CT: The ABCs [J].
Collins, J ;
Stern, EJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (02) :355-367
[3]   Real-time CT fluoroscopy: Evolution of an interventional tool [J].
Daly, B ;
Templeton, PA .
RADIOLOGY, 1999, 211 (02) :309-315
[4]   Value of CT fluoroscopy for percutaneous biopsy procedures [J].
Gianfelice, D ;
Lepanto, L ;
Perreault, P ;
Chartrand-Lefebvre, C ;
Milette, PC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (07) :879-884
[5]  
Greif J, 1998, CANCER CYTOPATHOL, V84, P144, DOI 10.1002/(SICI)1097-0142(19980625)84:3<144::AID-CNCR4>3.0.CO
[6]  
2-O
[7]   Diagnostic Accuracy of CT Fluoroscopy-Guided Needle Aspiration Biopsy of Ground-Glass Opacity Pulmonary Lesions [J].
Hur, Jin ;
Lee, Hye-Jeong ;
Nam, Ji Eun ;
Kim, Young Jin ;
Kim, Tae Hoon ;
Choe, Kyu Ok ;
Choi, Byoung Wook .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) :629-634
[8]   Air Embolism and Needle Track Implantation Complicating CT-Guided Percutaneous Thoracic Biopsy: Single-Institution Experience [J].
Ibukuro, Kenji ;
Tanaka, Rei ;
Takeguchi, Takaya ;
Fukuda, Hozumi ;
Abe, Shoko ;
Tobe, Kimiko .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) :W430-W436
[9]   Guidance with real-time CT fluoroscopy: Early clinical experience [J].
Katada, K ;
Kato, R ;
Anno, H ;
Ogura, Y ;
Koga, S ;
Ida, Y ;
Sato, M ;
Nonomura, K .
RADIOLOGY, 1996, 200 (03) :851-856
[10]   Persistent pulmonary nodular ground-glass opacity at thin-section CT: Histopathologic comparisons [J].
Kim, Ha Young ;
Shim, Young Mog ;
Lee, Kyung Soo ;
Han, Joungho ;
Yi, Chin A. ;
Kim, Yoon Kyung .
RADIOLOGY, 2007, 245 (01) :267-275