Effect of commutation failure on the distance protection and the countermeasures

被引:18
|
作者
Huang, Shao-feng [1 ]
Shen, Hong-ming [1 ]
Fei, Bin [1 ]
Li, Ou [1 ]
机构
[1] North China Elect Power Univ, Beijing 102206, Peoples R China
关键词
HVDC TRANSMISSION-SYSTEMS; FREQUENCY;
D O I
10.1049/iet-gtd.2014.0472
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Commutation failure (CF) may be caused by AC fault in AC/DC interconnected system, and it will affect the performance of distance protection. The transient characteristic of equivalent current of power-frequency of the dc-ac inverter is first analysed by introducing the concept of quadrant. Then, the effect of CF on distance protection is studied in detail with consideration of the connection mode of distance relay. The analysis results show that both the fault position and fault resistance contribute to the effect of CF on the performance of distance protection significantly. Furthermore, a novel countermeasure based on the amplitude of second harmonic is put forward, and a concept of 'successive trip' by using the change of measured reactance is also presented. Simulation results based on PSCAD/EMTDC prove the correctness of these conclusions.
引用
收藏
页码:838 / 844
页数:7
相关论文
共 50 条
  • [21] Study of the Effect of Commutation Circuit Parameters on Reliability of Quench Protection Unit in ITER
    Tong, Wei
    Song, Zhiquan
    Fu, Peng
    Zhang, Xiuqing
    Wang, Kun
    Hu, Xingguang
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 2224 - 2227
  • [22] Cause analysis and countermeasures on transformer backup-protection operation-failure accident
    Liu, Guilin
    Ma, Jinghui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (03): : 129 - 133
  • [23] Effect of Current Sensor Technology on Distance Protection
    Viawan, Ferry A.
    Wang, Jianping
    Wang, Zhao
    Yang, Winnary-Ying
    2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 1326 - +
  • [24] Effect of parallel line for a distance protection activities
    Chladny, Vladimir
    Hvizdos, Marek
    Mester, Marian
    PROCEEDINGS OF THE 5TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2003, 2003, : 411 - 420
  • [25] Effect of AC/DC interconnected network on transformer protection and its countermeasures
    Huang, Shaofeng
    Shen, Hongming
    Liu, Wei
    Zhao, Ke
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (23): : 158 - 164
  • [26] Impacts of DFIG-based wind farm integration on its tie line distance protection and countermeasures
    Chen, Xu
    Yin, Xianggen
    Zhang, Zhe
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2017, 12 (04) : 553 - 564
  • [27] Inverter-side valve short circuit fault location considering protection action and commutation failure
    Wang L.
    Huang M.
    Zhou S.
    Zeng X.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2023, 43 (08): : 133 - 140
  • [28] THE EFFECT OF AC SYSTEM FREQUENCY-SPECTRUM ON COMMUTATION FAILURE IN HVDC INVERTERS
    KRISTMUNDSSON, GM
    CARROLL, DP
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (02) : 1121 - 1128
  • [29] Simulation and Analysis on the Effect of Static Synchronous Compensation Device on HVDC Commutation Failure
    Li, Qiaoqiao
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON EDUCATION, MANAGEMENT, INFORMATION AND MECHANICAL ENGINEERING (EMIM 2017), 2017, 76 : 1632 - 1638
  • [30] Design a fuzzy controller to minimize the effect of HVDC commutation failure on power system
    Sun, Y. Z.
    Peng, Ling
    Ma, Feng
    Li, G. J.
    Lv, P. F.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (01) : 100 - 107