Ultrasound shear wave elastography in assessment of muscle stiffness in patients with Parkinson's disease: a primary observation

被引:57
作者
Du, Li-juan [1 ]
He, Wen [1 ]
Cheng, Ling-gang [1 ]
Li, Shuo [1 ]
Pan, Yue-song [2 ]
Gao, Jing [3 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, 6 Tiantanxili, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Tiantan Hosp, Dept Neurol, Beijing, Peoples R China
[3] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
关键词
Biceps brachii muscle; Parkinson's disease; Shear wave elastography; Young's modulus; MAGNETIC-RESONANCE ELASTOGRAPHY; GASTROCNEMIUS-MUSCLE; SKELETAL-MUSCLE; ELASTIC-MODULUS; HARDNESS; FEASIBILITY; EXERCISE;
D O I
10.1016/j.clinimag.2016.05.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to assess the capability of ultrasound shear wave elastography (SWE) in evaluating the muscle stiffness in patients with Parkinson's diseases (PD). Methods: Ultrasound SWE of the longitudinal biceps brachii was performed on 46 patients with PD and 31 healthy controls from May 2013 to October 2013. The stiffness of the biceps brachii muscles measured with quantitative Young's modulus (kPa) was compared between the remarkably symptomatic arms and mildly symptomatic arms in the PD and between PD and controls with unpaired t test. The correlation between the Young's modulus of the biceps brachii measured by SWE and motion scores assessed by unified Parkinson's disease rating scale (UPDRS) part III was analyzed by Pearson's correlation coefficient. The reliability of SWE in assessment of biceps brachii stiffness was tested using intraclass correlation coefficient (ICC). Results: The mean Young's modulus of biceps brachii in remarkably symptomatic arms, mildly symptomatic arms, and healthy controls was 59.94 +/- 20.91 kPa, 47.77 +/- 24.00 kPa, and 24.28 +/- 5.09 kPa, respectively. A significant difference in Young's modulus of biceps brachii was found between healthy controls and all PD patients (all P<.05); however, it was not between remarkably symptomatic and mildly symptomatic arms. A positive linear correlation was found between the Young's modulus of the biceps brachii and the motion score by UPDRS in patients with PD (r= 0.646, P=.000). The ICC for interobserver and intraobserver variation in measuring Young's modulus of the biceps brachii with SWE was 0.74 (95% confidence interval 0.68-0.78) and 0.78 (95% confidence interval 0.75-0.82), respectively. Conclusions: SWE of the biceps brachii can be used as a quantitative assessment of muscle stiffness in the patients with PD. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1075 / 1080
页数:6
相关论文
共 21 条
[1]   Acute Effect of Static Stretching on Hardness of the Gastrocnemius Muscle [J].
Akagi, Ryota ;
Takahashi, Hideyuki .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (07) :1348-1354
[2]   Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[3]   Reliability and Validity of Quantifying Absolute Muscle Hardness Using Ultrasound Elastography [J].
Chino, Kentaro ;
Akagi, Ryota ;
Dohi, Michiko ;
Fukashiro, Senshi ;
Takahashi, Hideyuki .
PLOS ONE, 2012, 7 (09)
[4]  
Fahn S., 1987, Recent Dev. Parkinsons Dis, P153, DOI DOI 10.2490/JJRMC.47.791
[5]   Measurement of muscle activity with magnetic resonance elastography [J].
Heers, G ;
Jenkyn, T ;
Dresner, MA ;
Klein, MO ;
Basford, JR ;
Kaufman, KR ;
Ehman, RL ;
An, KN .
CLINICAL BIOMECHANICS, 2003, 18 (06) :537-542
[6]   PARKINSONISM - ONSET PROGRESSION AND MORTALITY [J].
HOEHN, MM ;
YAHR, MD .
NEUROLOGY, 1967, 17 (05) :427-&
[7]   Parkinson's disease: clinical features and diagnosis [J].
Jankovic, J. .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2008, 79 (04) :368-376
[8]   Noninvasive muscle tension measurement using the novel technique of magnetic resonance elastography (MRE) [J].
Jenkyn, TR ;
Ehman, RL ;
An, KN .
JOURNAL OF BIOMECHANICS, 2003, 36 (12) :1917-1921
[9]   Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus [J].
Lacourpaille, Lilian ;
Hug, Francois ;
Bouillard, Killian ;
Hogrel, Jean-Yves ;
Nordez, Antoine .
PHYSIOLOGICAL MEASUREMENT, 2012, 33 (03) :N19-N28
[10]   Assessing the spastic condition of individuals with upper motoneuron involvement: Validity of the myotonometer [J].
Leonard, CT ;
Stephens, JU ;
Stroppel, SL .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (10) :1416-1420