A comprehensive review on energy efficiency enhancement initiatives in centrifugal pumping system

被引:246
作者
Kalaiselvan, Arun Shankar Vishnu [1 ]
Subramaniam, Umashankar [1 ]
Shanmugam, Paramasivam [2 ]
Hanigovszki, Norbert [3 ]
机构
[1] VIT Univ, Sch Elect Engn, Dept Energy & Power Elect, Vellore, Tamil Nadu, India
[2] Danfoss Drives R&D, Madras, Tamil Nadu, India
[3] Danfoss Drives R&D, Nordborg, Denmark
关键词
Improving energy efficiency; Component selection; Proper dimensioning; Optimal control strategies; Variable speed pumps; Variable Frequency Drives (VFD); SYNCHRONOUS RELUCTANCE MOTOR; VARIABLE-SPEED DRIVES; DIRECT TORQUE CONTROL; CONTROL STRATEGY; WATER; OPTIMIZATION; PERFORMANCE; LOSSES; MODEL; IMPLEMENTATION;
D O I
10.1016/j.apenergy.2016.08.070
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The energy consumption across the globe is increasing at an alarming rate. This has already shown its impact in the depletion of energy sources and environmental issues (global warming, and weakening of the ozone layer). Certainly, this escalating tendency of energy insufficiency will get aggravated in the future. Efficiency enhancement initiatives are considered to be the key solution in reducing the energy utilization and eventually resisting the global environmental impacts. Of the world's total energy generated, pumping systems, especially the centrifugal pumps consume about 20%. Consequently, the primary focus of global energy policy makers is to enhance energy efficiency in pumping systems. As per the literature, remarkable energy savings can be accomplished by controlling the speed of the pumping system using Variable Frequency Drives (VFDs). For this reason, studies and researches focus primarily on VFD control techniques to improve the efficiency of the pumping system. This article also focuses on component selection, and system dimensioning in addition to the control techniques. Comparison of recent research outcomes of energy efficiency improvements in pumping system has been made to provide an insight for future research. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:495 / 513
页数:19
相关论文
共 108 条
[1]   A review on energy saving strategies in industrial sector [J].
Abdelaziz, E. A. ;
Saidur, R. ;
Mekhilef, S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01) :150-168
[2]  
Ahonen T., 2011, Monitoring of Centrifugal Pump Operation by Frequency Converter
[3]  
Ahonen T, 2011, 7 INT C EEM
[4]  
Ahonen T., 2014, 2014 16 EUR C POW EL, P1, DOI [10.1109/EPE.2014.6910989, DOI 10.1109/EPE.2014.6910989]
[5]   Frequency-Converter-Based Hybrid Estimation Method for the Centrifugal Pump Operational State [J].
Ahonen, Tero ;
Tamminen, Jussi ;
Ahola, Jero ;
Kestila, Juha .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (12) :4803-4809
[6]   Estimation of pump operational state with model-based methods [J].
Ahonen, Tero ;
Tamminen, Jussi ;
Ahola, Jero ;
Viholainen, Juha ;
Aranto, Niina ;
Kestila, Juha .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (06) :1319-1325
[7]   FEM modeling of rotor losses in PM motors [J].
Al-Naemi, Faris Inthar ;
Moses, Anthony John .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2006, 304 (02) :E794-E797
[8]  
[Anonymous], 2005, IEEE T IND APPL, DOI DOI 10.1109/TIA.2004.841022
[9]  
[Anonymous], 2014, EXTENDED PRODUCT APPROACH FOR PUMPS
[10]  
[Anonymous], 2011, INT ENERGY AGENCY, DOI DOI 10.1787/20792581