Quality assurance of onboard megavoltage computed tomography imaging and target localization systems for on- and off-line image-guided radiotherapy

被引:7
作者
Langen, Katja M. [1 ]
Meeks, Sanford L. [1 ]
Pouliot, Jean [2 ]
机构
[1] MD Anderson Canc Ctr, Orlando, FL 32806 USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, Ctr Comprehens Canc, San Francisco, CA 94143 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 71卷 / 01期
关键词
megavoltage computed tomography; in-room imaging;
D O I
10.1016/j.ijrobp.2007.04.094
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We reviewed the quality assurance procedures that have been used to test fan- and cone-beam megavoltage-based in-room imaging systems. Phantom-based tests have been used to establish the geometric accuracy and precision of megavoltage-based systems. However, the clinical implementation of any system is accompanied by challenges that are best tested in a clinical setting using clinical images. To objectively judge and monitor image quality, a set of standard tests and phantoms can be used. The image noise and spatial and contrast resolution have been assessed using standard computed tomography phantoms. The dose to the patient resulting from the imaging procedure can be determined using calculations or measurements. The off-line use of patient images is of interest for the evaluation of dosimetric changes throughout the treatment course. The accuracy of the dosimetric calculations based on the megavoltage images has been tested for the fan- and cone-beam systems. Some of the described tests are typically performed before the clinical implementation of the imaging system; others are suited to monitor the system's performances. (C) 2008 Elsevier Inc.
引用
收藏
页码:S62 / S65
页数:4
相关论文
共 17 条
[1]   RADIOTHERAPEUTIC COMPUTED-TOMOGRAPHY WITH SCANNED PHOTON BEAMS [J].
BRAHME, A ;
LIND, B ;
NAFSTADIUS, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (01) :95-101
[2]   Image quality assessment for an investigational megavoltage Cone-Beam CT device [J].
Chen, H. ;
Simpson, L. ;
Morin, O. ;
Pouliot, J. ;
Sarkar, A. .
MEDICAL PHYSICS, 2006, 33 (06) :2038-2038
[3]   Patient dose and image quality from mega-voltage cone beam computed tomography imaging [J].
Gayou, Olivier ;
Parda, David S. ;
Johnson, Mark ;
Miften, Moyed .
MEDICAL PHYSICS, 2007, 34 (02) :499-506
[4]   A feasible method for clinical delivery verification and dose reconstruction in tomotherapy [J].
Kapatoes, JM ;
Olivera, GH ;
Ruchala, KJ ;
Smilowitz, JB ;
Reckwerdt, PJ ;
Mackie, TR .
MEDICAL PHYSICS, 2001, 28 (04) :528-542
[5]   The use of megavoltage CT (MVCT) images for dose recomputations [J].
Langen, KM ;
Meeks, SL ;
Poole, DO ;
Wagner, TH ;
Willoughby, TR ;
Kupelian, PA ;
Ruchala, KJ ;
Haimerl, J ;
Olivera, GH .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (18) :4259-4276
[6]   Initial experience with megavoltage (MV) CT guidance for daily prostate alignments [J].
Langen, KM ;
Zhang, YS ;
Andrews, RD ;
Hurley, ME ;
Meeks, SL ;
Poole, DO ;
Willoughby, TR ;
Kupelian, PA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (05) :1517-1524
[7]   Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit [J].
Meeks, SL ;
Harmon, JF ;
Langen, KM ;
Willoughby, TR ;
Wagner, TH ;
Kupelian, PA .
MEDICAL PHYSICS, 2005, 32 (08) :2673-2681
[8]   Juices: When and how much [J].
Morin, KH .
MCN-THE AMERICAN JOURNAL OF MATERNAL-CHILD NURSING, 2006, 31 (01) :61-61
[9]   Dose delivered to patients for megavoltage cone-beam CT imaging [J].
Morin, O. ;
Bellerose, J. ;
Descovich, M. ;
Aubin, N. ;
Chen, J. ;
Aubry, J. ;
Chen, H. ;
Pouliot, J. .
MEDICAL PHYSICS, 2006, 33 (06) :1999-1999
[10]  
MORIN O, 2006, INT J RADIAT ONCOL, V66, pS637