Two Orthogonal Nitinol Staples and Combined Nitinol Staple-Screw Constructs for a First Metatarsophalangeal Joint Arthrodesis: A Biomechanical Cadaver Study

被引:7
作者
Schafer, Kevin A. [1 ]
Baldini, Todd [2 ]
Hamati, Mary [2 ]
Backus, Jonathon D. [1 ]
Hunt, Kenneth J. [2 ]
McCormick, Jeremy J. [1 ]
机构
[1] Washington Univ, Dept Orthoped Surg, 425 S Euclid Ave,Suite 5505, St Louis, MO 63110 USA
[2] Univ Colorado, Dept Orthopaed Surg, Sch Med, Aurora, CO USA
关键词
metatarsophalangeal fusion; hallux rigidus; nitinol staples; NONLOCKED PLATE FIXATION; LOCKING PLATE; COMPRESSION STAPLES; CROSSED SCREWS; DORSAL PLATE;
D O I
10.1177/10711007221119157
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: End-stage hallux metatarsophalangeal (MTP) joint arthritis is commonly treated with arthrodesis using stainless steel or titanium implants. These implants provide static compression that is maximal at the time of implant insertion. Alternatively, nitinol staples are capable of dynamic compression. They have most frequently been used for midfoot arthrodesis procedures. However, their biomechanical performance during hallux MTP arthrodesis has not been described. Methods: 8 matched pairs of cadaveric feet (4 female, 4 male) were prepared for hallux MTP arthrodesis using cup and cone reamers. Cadaveric pairs were then instrumented with either (1) a transarticular lag screw and dorsal nitinol staple or (2) orthogonal nitinol staples placed dorsally and medially. Walking in a short leg cast for 6 weeks was simulated by applying 90-N forces at 3 Hz to the plantar proximal phalanx for up to 250 000 cycles. Failure was defined as catastrophic implant failure or plantar gapping beyond 7 mm. Results: 15 of 16 specimens failed cyclic loading. All 8 specimens fixed with orthogonal staples failed at an average of 37 +/- 81 cycles. 7 of 8 specimens fixed with a dorsal staple and crossed screw failed at 14 900 +/- 39 000 cycles. Collectively, 5 specimens failed because of bone fracture (1 in orthogonal staples, 4 in staple-screw group) and 10 failed because of excessive gap formation (7 in orthogonal staples, 3 in staple-screw group). The number of cycles to failure was significantly lower (P = .0469) in the orthogonal staple constructs compared with the dorsal staple and crossed screw constructs. Conclusion: The tested constructs permit significant motion at the first MTP fusion surface during simulated protected weightbearing. Although multiple in vivo factors should be considered when extrapolating results from this cadaveric study, this motion may result in clinical failure with early postoperative weightbearing protocols.
引用
收藏
页码:1493 / 1500
页数:8
相关论文
共 31 条
[1]  
Aiyer Amiethab, 2016, Foot Ankle Spec, V9, P232, DOI [10.1177/1938640015620655, 10.1177/1938640015620655]
[2]   Failure of Fixation With Nickel-Titanium Staples in First Metatarsophalangeal Arthrodesis With Hallux Valgus Deformity [J].
Chan, Jimmy J. ;
Sarkar, Salman S. ;
Nordio, Andrea ;
Guzman, Javier Z. ;
Hasija, Rohit ;
Vulcan, Ettore .
ORTHOPEDICS, 2019, 42 (04) :E402-E404
[3]  
Choudhary Rakesh K, 2004, J Foot Ankle Surg, V43, P312, DOI 10.1053/j.jfas.2004.07.003
[4]   First Metatarsophalangeal Joint Arthrodesis: Does the Addition of a Lag Screw to a Dorsal Locking Plate Influence Union Rate and/or Final Alignment after Fusion [J].
Cone, Brent ;
Staggers, Jackson R. ;
Naranje, Sameer ;
Hudson, Parke ;
Ingram, Joseph ;
Shah, Ashish .
JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (02) :259-263
[5]   Early Weight-Bearing After Arthrodesis of the First Metatarsal-Phalangeal Joint: A Systematic Review of the Incidence of Non-Union [J].
Crowell, Amanda ;
Van, Jennifer C. ;
Meyr, Andrew J. .
JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (06) :1200-1203
[6]   First metatarsophalangeal arthrodesis: A clinical, pedobarographic and gait analysis study [J].
DeFrino, PF ;
Brodsky, JW ;
Pollo, FE ;
Crenshaw, SJ ;
Beischer, AD .
FOOT & ANKLE INTERNATIONAL, 2002, 23 (06) :496-502
[7]  
Dock Carissa C, 2020, Foot Ankle Orthop, V5, p2473011420944904, DOI [10.1177/2473011420944904, 10.1177/2473011420944904]
[8]   Hallux Metatarsophalangeal Joint Arthrodesis With a Hybrid Locking Plate and a Plantar Neutralization Screw: A Prospective Study [J].
Doty, Jesse ;
Coughlin, Michael ;
Hirose, Christopher ;
Kemp, Travis .
FOOT & ANKLE INTERNATIONAL, 2013, 34 (11) :1535-1540
[9]   Biomechanical Comparison of Low-Profile Contoured Locking Plate With Single Compression Screw to Fully Threaded Compression Screws for First MTP Fusion [J].
Fuld, Richard S., III ;
Kumparatana, Pam ;
Kelley, Judas ;
Anderson, Nicholas ;
Baldini, Todd ;
Younger, Alastair S. E. ;
Hunt, Kenneth J. .
FOOT & ANKLE INTERNATIONAL, 2019, 40 (07) :836-844
[10]   Hallux metatarsophalangeal joint arthrodesis using dome-shaped reamers and dorsal plate fixation: A prospective study [J].
Goucher, Nicholas R. ;
Coughlin, Michael J. .
FOOT & ANKLE INTERNATIONAL, 2006, 27 (11) :869-876