Agreement of intraocular lens power calculation between 2 SS-OCT-based biometers

被引:10
|
作者
Pfaeffli, Oliver A. [1 ]
Weber, Adrian [1 ]
Hoffer, Kenneth J. [2 ,3 ]
Savini, Giacomo [4 ]
Baenninger, Philipp B. [1 ]
Thiel, Michael A. [1 ]
Taroni, Leonardo [5 ]
Mueller, Luzia [1 ]
机构
[1] Cantonal Hosp Lucerne, Dept Ophthalmol, Luzern, Switzerland
[2] Univ Calif Los Angeles, Stein Eye Inst, Los Angeles, CA USA
[3] St Marys Eye Ctr, Santa Monica, CA USA
[4] Fondazione G B Bietti IRCCS, Rome, Italy
[5] Univ Bologna, S Orsola Malpighi Univ Hosp, Eye Clin, Bologna, Italy
关键词
OPTICAL COHERENCE TOMOGRAPHY; INTERFEROMETRY; REPEATABILITY; CONCORDANCE;
D O I
10.1097/j.jcrs.0000000000000788
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess agreement of measurements by 2 swept-source optical coherence tomography biometers and to evaluate the prediction error (PE) in intraocular lens power calculation with 7 formulas. Setting: Tertiary public eye hospital. Design: Consecutive observational. Methods: Axial length (AL), keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and corneal diameter (CD) were measured with the IOLMaster 700 (Biometer A) and Anterion (Biometer B). Agreement was quantified by the limits of agreement and concordance correlation coefficient (CCC). The PE, the median absolute error, and the mean absolute error of the Barrett Universal II, EVO 2.0, Haigis, Hoffer Q, Holladay 1, Kane, and SRK/T formulas were investigated after constant optimization. Results: In 78 eyes from 78 patients, excellent agreement was obtained for AL (CCC >0.99), very good agreement for K, ACD, and LT (CCC >0.95), and strong agreement for CD (CCC >0.72). An additive offset of 0.07 mm was measured for ACD and LT whose mean values were higher with Biometer B (P <.001). No statistically significant difference was found between the PEs and their absolute values when comparing the results of each formula between the 2 biometers. Conclusions: Agreement of biometric measurements by the 2 biometers was high, although Biometer B provided higher mean values of ACD and LT by 0.07 mm. In cataract patients with normal eye length, measurements by the 2 biometers did not lead to different refractive outcomes with the 7 formulas investigated.
引用
收藏
页码:535 / 541
页数:7
相关论文
共 49 条
  • [21] Interobserver agreement between central topography and Scheimpflug tomography for premium intraocular lens selection
    Brar, Sheetal
    Ganesh, Sri
    Murkey, Vedant
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (08) : 790 - 794
  • [22] Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation
    Kirgiz, Ahmet
    Atalay, Kursat
    Kaldirim, Havva
    Cabuk, Kubra Serefoglu
    Akdemir, Mehmet Orcun
    Taskapili, Muhittin
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 781 - 786
  • [23] Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug camera
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04) : 598 - 604
  • [24] Calculation of Toric Intraocular Lens Power with the Barrett Calculator and Data from Three Keratometers
    Dong, Jing
    Zhang, Yaqin
    Wang, Xiaogang
    JOURNAL OF TROPICAL MEDICINE, 2021, 2021
  • [25] Ultrasound biometry and intraocular lens power calculation: comparative study of the contact and immersion techniques
    Re Martins, Felipe Cortizas
    Miyaji, Marcos Enrique
    Lima, Vagner Loduca
    Carvalho Lima Rehder, Jose Ricardo
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2009, 68 (04) : 212 - 215
  • [26] Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery
    Wu, Yubo
    Liu, Songyu
    Liao, Rongfeng
    BMC OPHTHALMOLOGY, 2017, 17
  • [27] Corneal power estimation for intraocular lens power calculation after corneal laser refractive surgery in Chinese eyes
    Jin, Haiying
    Auffarth, Gerd U.
    Guo, Haike
    Zhao, Peiquan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10) : 1749 - 1757
  • [28] Comparison of Newer Intraocular Lens Power Calculation Methods for Eyes after Corneal Refractive Surgery
    Wang, Li
    Tang, Maolong
    Huang, David
    Weikert, Mitchell P.
    Koch, Douglas D.
    OPHTHALMOLOGY, 2015, 122 (12) : 2443 - 2449
  • [29] Intraocular lens power calculation by measuring axial length with partial optical coherence and ultrasonic biometry
    Fontes, Beatriz Machado
    Fontes, Bruno Machado
    Castro, Elaine
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2011, 74 (03) : 166 - 170
  • [30] Ray tracing optimization: a new method for intraocular lens power calculation in regular and irregular corneas
    Perez-Merino, Pablo
    Aramberri, Jaime
    Quintero, Andres Vasquez
    Rozema, Jos J.
    SCIENTIFIC REPORTS, 2023, 13 (01)