Outcomes of stent thrombosis and restenosis during extended follow-up of patients treated with bare-metal coronary stents

被引:179
作者
Doyle, Brendan [1 ]
Rihal, Charanjit S. [1 ]
O'Sullivan, Crochan J. [1 ]
Lennon, Ryan J. [1 ]
Wiste, Heather J. [1 ]
Bell, Malcolm [1 ]
Bresnahan, John [1 ]
Holmes, David R., Jr. [1 ]
机构
[1] Coll Med, Mayo Clin, Dept Internal Med, Div Cardiovasc Dis, Rochester, MN 55905 USA
关键词
myocardial infarction; restenosis; stents; thrombosis;
D O I
10.1161/CIRCULATIONAHA.107.707331
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Concern regarding risk of late thrombosis after "off-label" treatment with drug-eluting stents has prompted increased use of bare-metal stents (BMS) in current practice. The sequelae of late BMS failures, however, have been poorly characterized. Methods and Results - We performed a retrospective study of 4503 consecutive patients treated with at least 1 BMS and dual antiplatelet therapy between 1994 and 2000. The cumulative incidence of stent thrombosis was 0.5% at 30 days (95% CI, 0.3% to 0.7%), 0.8% at 1 year (95% CI, 0.6% to 1.1%), and 2.0% at 10 years (95% CI, 1.5% to 2.5%). Risk of late (30 days to 1 year) and very late (> 1 year) BMS thrombosis was increased among patients considered off label for drug-eluting stent use (P=0.024). When saphenous vein graft interventions were excluded, however, risk after off-label use was not significantly increased (P=0.23). Other correlates included vein graft intervention, prior myocardial infarction (MI), peripheral vascular disease, and ulcerated lesion (P < 0.001). Mortality was markedly increased after late and very late BMS thrombosis, particularly during the first 30 days (hazard ratios, 22 [95% CI, 3.1 to 159] and 40 [95% CI, 15 to 107], respectively). The 10-year incidence of clinical restenosis was 18.1% (95% CI, 16.5% to 19.7%), presenting with MI in 2.1% (95% CI, 1.6% to 2.6%). Restenosis presenting with MI was associated with increased mortality compared with no restenosis (hazard ratio, 2.37; P < 0.001) and with restenosis with a non-MI presentation (hazard ratio, 2.42; P < 0.001). Conclusions - The incidence of BMS thrombosis and of MI caused by restenosis during extended follow-up is significant. Both complications are associated with mortality.
引用
收藏
页码:2391 / 2398
页数:8
相关论文
共 23 条
[1]   Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis [J].
Ako, J ;
Morino, Y ;
Honda, Y ;
Hassan, A ;
Sonoda, S ;
Yock, PG ;
Leon, MB ;
Moses, JW ;
Bonneau, HN ;
Fitzgerald, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) :1002-1005
[2]   Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction [J].
Alpert, JS ;
Antman, E ;
Apple, F ;
Armstrong, PW ;
Bassand, JP ;
de Luna, AB ;
Beller, G ;
Breithardt, G ;
Chaitman, BR ;
Clemmensen, P ;
Falk, E ;
Fishbein, MC ;
Galvani, M ;
Garson, A ;
Grines, C ;
Hamm, C ;
Jaffe, A ;
Katus, H ;
Kjekshus, J ;
Klein, W ;
Klootwijk, P ;
Lenfant, C ;
Levy, D ;
Levy, RI ;
Luepker, R ;
Marcus, F ;
Näslund, U ;
Ohman, M ;
Pahlm, O ;
Poole-Wilson, P ;
Popp, R ;
Alto, P ;
Pyörälä, K ;
Ravkilde, J ;
Rehnquist, N ;
Roberts, W ;
Roberts, R ;
Roelandt, J ;
Rydén, L ;
Sans, S ;
Simoons, ML ;
Thygesen, K ;
Tunstall-Pedoe, H ;
Underwood, R ;
Uretsky, BF ;
Van de Werf, F ;
Voipio-Pulkki, LM ;
Wagner, G ;
Wallentin, L ;
Wijns, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :959-969
[3]   Stent thrombosis late after implantation of first-generation drug-eluting stents - A cause for concern [J].
Camenzind, Edoardo ;
Steg, P. Gabriel ;
Wijns, William .
CIRCULATION, 2007, 115 (11) :1440-1455
[4]   Late stent thrombosis in the nonbrachytherapy population: A real phenomenon? [J].
Casserly, IP ;
Goldstein, JA ;
Lasala, JM .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 59 (04) :504-508
[5]   Bare metal stent restenosis is not a benign clinical entity [J].
Chen, Michael S. ;
John, Jim M. ;
Chew, Derek P. ;
Lee, David S. ;
Ellis, Stephen G. ;
Bhatt, Deepak L. .
AMERICAN HEART JOURNAL, 2006, 151 (06) :1260-1264
[6]  
Cutlip DE, 2001, CIRCULATION, V103, P1967
[7]   Pathological mechanisms of fatal late coronary stent thrombosis in humans [J].
Farb, A ;
Burke, AP ;
Kolodgie, FD ;
Virmani, R .
CIRCULATION, 2003, 108 (14) :1701-1706
[8]   Histopathological findings of new in-stent lesions developed beyond five years [J].
Hasegawa, Katsuyuki ;
Tamai, Hideo ;
Kyo, Eisho ;
Kosuga, Kunihiko ;
Ikeguchi, Shigeru ;
Hata, Tatsuhiko ;
Okada, Masaharu ;
Fujita, Shinya ;
Tsuji, Takafumi ;
Takeda, Shinsaku ;
Fukuhara, Rei ;
Kikuta, Yuetsu ;
Motohara, Seiichiro ;
Ono, Kazuo ;
Takeuchi, Eiji .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (04) :554-558
[9]   Pathology of drug-eluting stents in humans - Delayed healing and late thrombotic risk [J].
Joner, Michael ;
Finn, Aloke V. ;
Farb, Andrew ;
Mont, Erik K. ;
Kolodgie, Frank D. ;
Ladich, Elena ;
Kutys, Robert ;
Skorija, Kristi ;
Gold, Herman K. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :193-202
[10]   Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents [J].
Kastrati, Adnan ;
Mehilli, Julinda ;
Pache, Juergen ;
Kaiser, Christoph ;
Valgimigli, Marco ;
Kelbaek, Henning ;
Menichelli, Maurizio ;
Sabate, Manel ;
Suttorp, Maarten J. ;
Baumgart, Dietrich ;
Seyfarth, Melchior ;
Pfisterer, Matthias E. ;
Schoemig, Albert .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10) :1030-1039