Transcutaneous monitoring as a replacement for arterial PCO2 monitoring during nocturnal non-invasive ventilation

被引:95
作者
Storre, Jan Hendrik [1 ]
Magnet, Friederike Sophie [1 ]
Dreher, Michael [1 ]
Windisch, Wolfram [1 ]
机构
[1] Univ Hosp Freiburg, Dept Pneumol, D-79106 Freiburg, Germany
关键词
Alveolar ventilation; Carbon dioxide; Monitoring; Nocturnal ventilation; Sleep; Transcutaneous pressure of carbone dioxid; STABLE HYPERCAPNIC COPD; POSITIVE-PRESSURE VENTILATION; CHRONIC RESPIRATORY-FAILURE; RANDOMIZED CROSSOVER TRIAL; CARBON-DIOXIDE; MECHANICAL VENTILATION; CRITICALLY-ILL; CLINICAL-EVALUATION; NASAL VENTILATION; HIGH-INTENSITY;
D O I
10.1016/j.rmed.2010.10.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Continuous, non-invasive assessment of alveolar ventilation achieved by transcutaneous PCO2 (PtcCO(2)) monitoring is clearly superior to intermittent, invasive blood gas analyses in patients receiving nocturnal non-invasive positive pressure ventilation (NPPV), but the reliability and accuracy of PtcCO(2)-monitoring is still disputed. The present study was aimed at investigating the capability of modern PtcCO(2)-monitoring to reliably assess alveolar ventilation during nocturnal NPPV. Methods: Capillary blood gas measurements (11pm, 2am, 5am and 7am) and 8 h of continuous PtcCO(2)-monitoring using three of the latest generation devices (SenTec Digital Monitor, Radiometer TCM4-TINA and Radiometer TOSCA500) were performed during polysomnography-proven sleep studies in 24 patients receiving NPPV (15 with COPD, 9 with restrictive disorders). Results: The technical calibration drift for SenTec DM, TCM4-TINA and TOSCA500 was 0.1, -0.4 and -0.5 mmHg/h, respectively. Bland-Altman method comparison of PaCO2/drift-uncorrected PtcCO(2) revealed a mean bias (limits of agreement) of 1.0 (-4.7 to 6.7), -1.5 (-15.6 to 12.5) and 0.8 (-6.8 to 8.3) mmHg, respectively. Continuous overnight PtcCO(2)-monitoring detected variations in alveolar ventilation, with median ranges of 12.3 (10.7-14.5) mmHg for SenTec DM, 14.5 (12.5-17.0) mmHg for TCM4-TINA and 11.5 (11.0-13.0) mmHg for TOSCA500 (RM-ANOVA, p < 0.001). The four capillary PaCO2 values ranged by a median of 6.3 (4.7-9.7) mmHg. Conclusions: Modern PtcCO(2)-monitoring is reliable, accurate and robust. Since PtcCO(2)-monitoring is also non-invasive, does not disrupt sleep quality and provides a more complete picture of alveolar ventilation than intermittent capillary PaCO2, PtcCO(2)-monitoring should become the preferred technique for assessing alveolar ventilation during nocturnal NPPV. Trial Registration: DRKS00000433 at http://apps.who.int/trialsearch/default.aspx. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 49 条
[1]  
[Anonymous], 1999, CHEST, V116, P521
[2]   Breathing during sleep in patients with nocturnal desaturation [J].
Becker, HF ;
Piper, AJ ;
Flynn, WE ;
McNamara, SG ;
Grunstein, RR ;
Peter, JH ;
Sullivan, CE .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (01) :112-118
[3]   Transcutaneous Pco2 monitoring in critically ill adults:: Clinical evaluation of a new sensor [J].
Bendjelid, K ;
Schütz, N ;
Stotz, M ;
Gerard, I ;
Suter, PM ;
Romand, JA .
CRITICAL CARE MEDICINE, 2005, 33 (10) :2203-2206
[4]   REGRESSION-ANALYSIS [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8486) :908-909
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   The accuracy of non-invasive carbon dioxide monitoring: A clinical evaluation of two transcutaneous systems [J].
Bolliger, D. ;
Steiner, L. A. ;
Kasper, J. ;
Aziz, O. A. ;
Filipovic, M. ;
Seeberger, M. D. .
ANAESTHESIA, 2007, 62 (04) :394-399
[7]   Transcutaneous monitoring of partial pressure of carbon dioxide in the elderly patient: a prospective, clinical comparison with end-tidal monitoring [J].
Casati, Andrea ;
Squicciarini, Grazia ;
Malagutti, Giulia ;
Baciarello, Marco ;
Putzu, Marta ;
Fanelli, Andrea .
JOURNAL OF CLINICAL ANESTHESIA, 2006, 18 (06) :436-440
[8]  
Chhajed Prashant N, 2004, Curr Opin Anaesthesiol, V17, P521, DOI 10.1097/00001503-200412000-00014
[9]   Non-invasive monitoring of CO2 levels in patients using NIV for AECOPD [J].
Cox, M ;
Kemp, R ;
Anwar, S ;
Athey, V ;
Aung, T ;
Moloney, ED .
THORAX, 2006, 61 (04) :363-364
[10]   Limitations of transcutaneous carbon dioxide measurements for assessing long-term mechanical ventilation [J].
Cuvelier, A ;
Grigoriu, B ;
Molano, LC ;
Muir, JF .
CHEST, 2005, 127 (05) :1744-1748