An investigation of the accuracy of an IMRT dose distribution using two- and three-dimensional dosimetry techniques

被引:53
作者
Oldham, Mark [1 ]
Sakhalkar, Harshad [1 ]
Guo, Pengyi [1 ]
Adamovics, John [2 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC 27710 USA
[2] Rider Univ, Dept Biol & Chem, Lawrenceville, NJ 08648 USA
关键词
dosimetry; 3D; PRESAGE; optical; computed tomography; CT; IMRT; quality assurance; gel;
D O I
10.1118/1.2899995
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Complex dose delivery techniques like intensity-modulated radiation therapy (IMRT) require dose measurement in three dimensions for comprehensive validation. Previously, we demonstrated the feasibility of the "PRESAGE (TM)/optical-computed tomography (CT)" system for the three-dimensional verification of simple open beam dose distributions where the planning system was known to be accurate. The present work extends this effort and presents the first application of the PRESAGE (TM)/optical-CT system for the verification of a complex IMRT distribution. A highly modulated 11 field IMRT plan was delivered to a cylindrical PRESAGE (TM) dosimeter (16 cm in diameter and 11 cm in height), and the dose distribution was readout using a commercial scanning-laser optical-CT scanner. Comparisons were made with independent GAFCHROMIC (R) EBT film measurements, and the calculated dose distribution from a commissioned treatment planning system (ECLIPSE (R)). Isodose plots, dose profiles, gamma maps, and dose-volume histograms were used to evaluate the agreement. The isodose plots and dose profiles from the PRESAGE (TM)/optical-CT system were in excellent agreement with both the EBT measurements and the ECLIPSE (R) calculation at all points except within 3 mm of the outer edge of the dosimeter where an edge artifact occurred. Excluding this 3 mm rim, gamma map comparisons show that all three distributions mutually agreed to within a 3% (dose difference) and 3 mm (distance-to-agreement) criteria. A 96% gamma pass ratio was obtained between the PRESAGE (TM) and ECLIPSE (R) distributions over the entire volume excluding this rim. In conclusion, for the complex IMRT plan studied, and in the absence of inhomogeneities, the ECLIPSE (R) dose calculation was found to agree with both independent measurements, to within 3%, 3 mm gamma criteria. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:2072 / 2080
页数:9
相关论文
共 23 条
[1]   Characterisation of PRESAGE™:: A new 3-D radiochromic solid polymer dosemeter for ionising radiation [J].
Adamovics, J. ;
Maryanski, M. J. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :107-112
[2]  
De Deene Yves, 2002, Z Med Phys, V12, P77
[3]   Precise radiochromic film dosimetry using a flat-bed document scanner [J].
Devic, S ;
Seuntjens, J ;
Sham, E ;
Podgorsak, EB ;
Schmidtlein, CR ;
Kirov, AS ;
Soares, CG .
MEDICAL PHYSICS, 2005, 32 (07) :2245-2253
[4]   Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance [J].
Fuss, Martina ;
Sturtewagen, Eva ;
De Wagter, Carlos ;
Georg, Dietmar .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14) :4211-4225
[5]   Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels .1. Development of an optical scanner [J].
Gore, JC ;
Ranade, M ;
Maryanski, MJ ;
Schulz, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2695-2704
[6]   Characterization of a new radiochromic three-dimensional dosimeter [J].
Guo, P. Y. ;
Adamovics, J. A. ;
Oldham, M. .
MEDICAL PHYSICS, 2006, 33 (05) :1338-1345
[7]   A practical three-dimensional dosimetry system for radiation therapy [J].
Guo, Pengyi ;
Adamovics, John ;
Oldham, Mark .
MEDICAL PHYSICS, 2006, 33 (10) :3962-3972
[8]   Technical considerations for implementation of X-ray CT polymer gel dosimetry [J].
Hilts, M ;
Jirasek, A ;
Duzenli, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08) :1727-1745
[9]   Independent evaluations of IMRT through the use of an anthropomorphic phantom [J].
Ibbott, Geoffrey S. ;
Molineu, Andrea ;
Followill, David S. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2006, 5 (05) :481-487
[10]   Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter [J].
Kelly, RG ;
Jordan, KJ ;
Battista, JJ .
MEDICAL PHYSICS, 1998, 25 (09) :1741-1750