EVALUATION OF AORTIC ROOT FOR DEFINITION OF PROSTHESIS SIZE BY MAGNETIC RESONANCE IMAGING AND CARDIAC COMPUTED TOMOGRAPHY: IMPLICATIONS FOR TRANSCATHETER AORTIC VALVE IMPLANTATION

被引:0
作者
Koos, Ralf [1 ]
Altiok, Ertunc [1 ]
Mahnken, Andreas Horst [1 ]
Neizel, Mirja [1 ]
Dohmen, Guido [1 ]
Marx, Nikolaus [1 ]
Kuehl, Harald [1 ]
Hoffmann, Rainer [1 ]
机构
[1] Univ Hosp RWTH Aachen, Dept Cardiol, Aachen, Germany
关键词
D O I
10.1016/S0735-1097(11)61337-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:E1337 / E1337
页数:1
相关论文
共 50 条
[31]   Hemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using the dimensionless aortic regurgitation index compared to cardiac magnetic resonance imaging [J].
Merten, C. ;
El-Mawardy, M. ;
Beurich, H. ;
Abdel-Wahab, M. ;
Zachow, D. ;
Richardt, G. .
EUROPEAN HEART JOURNAL, 2014, 35 :424-424
[32]   Measurement of Aortic Valve Annulus Using Different Cardiac Imaging Techniques in Transcatheter Aortic Valve Implantation: Agreement with Finally Implanted Prosthesis Size [J].
Mesa Rubio, Dolores ;
Cruz Conde, Jose Suarez de Lezo ;
Pan Alvarez-Osorio, Manuel ;
Ruiz Ortiz, Martin ;
Delgado Ortega, Monica ;
del Carmen Leon del Pino, Maria ;
Toledano Delgado, Francisco ;
Segura Saint-Gerons, Jose ;
Ojeda Pineda, Soledad ;
Garcia Fuertes, Daniel ;
Crespin Crespin, Manuel ;
Espejo, Simon ;
Ysamat, Rusel .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (04) :388-396
[33]   Cardiac computed tomography measurement of aortic annular diameter: Implications for percutaneous aortic valve implantation [J].
Woo, David A. ;
Pasupati, Sanjeevan ;
Chandavimol, Mann ;
Humphries, Karin ;
Thompson, Chris ;
Mayo, John ;
Webb, John .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) :139A-139A
[34]   Cardiac Computed Tomography and Magnetic Resonance Imaging in the Evaluation of Mitral and Tricuspid Valve Disease: Implications for Transcatheter Interventions [J].
Naoum, Christopher ;
Blanke, Philipp ;
Cavalcante, Joao L. ;
Leipsic, Jonathon .
CIRCULATION-CARDIOVASCULAR IMAGING, 2017, 10 (03)
[35]   Multidetector Computed Tomography to Facilitate Transcatheter Aortic Valve Implantation [J].
Leipsic J. ;
Wood D.A. ;
Gurvitch R. ;
Hague C.J. .
Current Cardiovascular Imaging Reports, 2011, 4 (6) :457-467
[36]   Role of Preprocedural Computed Tomography in Transcatheter Aortic Valve Implantation [J].
Lehmkuhl, L. ;
Foldyna, B. ;
Haensig, M. ;
von Aspern, K. ;
Luecke, C. ;
Andres, C. ;
Grothoff, M. ;
Riese, F. ;
Nitzsche, S. ;
Holzhey, D. ;
Linke, A. ;
Mohr, F. -W. ;
Gutberlet, M. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (10) :941-949
[37]   Multimodality imaging in transcatheter aortic valve implantation and post-procedural outcome: comparison between cardiovascular magnetic resonance, cardiac computed tomography and echocardiography [J].
Jabbour, A. ;
Ismail, T. ;
Gulati, A. ;
Roussin, I. ;
Alpendurada, F. ;
Davies, S. ;
Mullen, M. ;
Rubens, M. ;
Moat, N. ;
Mohiaddin, R. .
EUROPEAN HEART JOURNAL, 2011, 32 :892-892
[38]   Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI) / transcatheter aortic valve replacement (TAVR): An expert consensus document of the Society of Cardiovascular Computed Tomography [J].
Blanke, Philipp ;
Weir-McCall, Jonathan R. ;
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Jilaihawi, Hasan ;
Marwan, Mohamed ;
Norgaard, Bjarne L. ;
Piazza, Niccolo ;
Schoenhagen, Paul ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (01) :1-20
[39]   Computed Tomography Imaging in the Context of Transcatheter Aortic Valve Implantation (TAVI)/Transcatheter Aortic Valve Replacement (TAVR) An Expert Consensus Document of the Society of Cardiovascular Computed Tomography [J].
Blanke, Philipp ;
Weir-McCall, Jonathan R. ;
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Jilaihawi, Hasan ;
Marwan, Mohamed ;
Norgaard, Bjarne L. ;
Piazza, Niccolo ;
Schoenhagen, Paul ;
Leipsic, Jonathon A. .
JACC-CARDIOVASCULAR IMAGING, 2019, 12 (01) :1-24
[40]   ANNULUS SIZE DETERMINATION BY COMPUTED TOMOGRAPHY IS RELIABLE AND REPRODUCIBLE IN TRANSCATHETER AORTIC VALVE IMPLANTATION [J].
Kim, Won-Jang ;
Kim, Ho-Cheol ;
Cho, Yong-Rak ;
Ahn, Jung-Min ;
Lee, Jong-Yong ;
Park, Duk-Woo ;
Kang, Soo-Jin ;
Lee, Seung-Whan ;
Kim, Young-Hak ;
Lee, Cheol Whan ;
Park, Seong-Wook ;
Park, Seung-Jung .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) :E1901-E1901