Accurate Quantification of Monoclonal Immunoglobulins Migrating in the Beta Region on Protein Electrophoresis

被引:3
|
作者
Omar, Nivin [1 ]
Madwani, Kiran [1 ]
Moideen, Pramila [1 ]
Manthei, David M. [2 ]
Keren, David F. [2 ]
Singh, Gurmukh [1 ]
机构
[1] Augusta Univ, Dept Pathol, Med Coll Georgia, Augusta, GA 30912 USA
[2] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
clinical pathology; clinical chemistry; immunology; immunopathology; monoclonal gammopathy; light chain-predominant multiple myeloma; FREE LIGHT-CHAIN; FOLLOW-UP; IMMUNOFIXATION; GAMMOPATHY; DIAGNOSIS; CRITERIA;
D O I
10.1093/labmed/lmab055
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background The concentration of monoclonal immunoglobulins (Igs) in neoplastic monoclonal gammopathic manifestations is generally measured by densitometric scanning of the monoclonal peaks on gel or by measuring absorbance at 210 nm in capillary electrophoresis (CE). For monoclonal Igs migrating in the beta region, measurement is complicated by the major beta-region proteins, namely, transferrin and C3. Methods C3 interference in densitometry was eliminated by heat treatment of serum, and monoclonal Igs were quantified by densitometry of the residual band. The immunochemical measurement of transferrin was converted to its equivalent densitometric quantity. For monoclonal Ig migrating with transferrin, the contribution of the latter was removed by subtracting the converted transferrin concentration from the combined densitometric quantification of the band. With CE, monoclonal Ig was measured by using immunosubtraction (ISUB) to guide demarcation. Results The results obtained using the C3 depletion and transferrin subtraction method were lower and yet comparable to the results derived from using CE measurement guided by ISUB. As we expected, the results from both methods were lower than those derived from a perpendicular drop measurement of the peak or via nephelometric assay of the involved isotype. Discussion Accurate measurement of monoclonal Igs is important for the diagnosis and monitoring of monoclonal gammopathic manifestations. Determination of serum free light chain concentration per gram of monoclonal Ig is an essential measure for the diagnosis of light chain-predominant multiple myeloma. The method described herein improves accuracy of measurements for monoclonal Igs migrating in the beta region, without the need for special reagents or equipment.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 38 条
  • [31] Detection and quantification of M-proteinemia: comparison of various methods for serum protein electrophoresis
    Bakker, Andries J.
    Elderman-van der Werf, Coby
    van Abbema, Tjallie
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (01) : 77 - 80
  • [32] Comparison of serum free light chain and urine electrophoresis for the detection of the light chain component of monoclonal immunoglobulins in light chain and intact immunoglobulin multiple myeloma
    Dejoie, Thomas
    Attal, Michel
    Moreau, Philippe
    Harousseau, Jean-Luc
    Avet-Loiseau, Herve
    HAEMATOLOGICA, 2016, 101 (03) : 356 - 362
  • [33] A comparison between high resolution serum protein electrophoresis and screening immunofixation for the detection of monoclonal gammopathies in serum
    Smith, Joel
    Raines, Geoffrey
    Schneider, Hans-Gerhard
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (02) : 256 - 263
  • [34] Detection of monoclonal protein by capillary zone electrophoresis can be challenged by iodinated contrast agent interference: a case report
    Capaldo, Clement
    El Aouni, Mourad Cheddad
    Laurelli, Damien
    Leven, Cyril
    Carre, Jean-Luc
    BIOCHEMIA MEDICA, 2021, 31 (02) : 021001
  • [35] Interference of Therapeutic Monoclonal Antibodies With Routine Serum Protein Electrophoresis and Immunofixation in Patients With Myeloma Frequency and Duration of Detection of Daratumumab and Elotuzumab
    Tang, Felicia
    Malek, Ehsan
    Math, Susan
    Schmotzer, Christine L.
    Beck, Rose C.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2018, 150 (02) : 121 - 129
  • [36] Dynamic monitoring of M-protein quantification by immunotyping using capillary zone electrophoresis during the chemotherapy of patients with multiple myeloma
    Jia, Zhongwei
    Lu, Qiong
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [37] Characterization of a novel monoclonal antibody reactive against the N-terminal region of Enterovirus 71 VP1 capsid protein
    Lim, Xiao Fang
    Jia, Qiang
    Chow, Vincent T. K.
    Kwang, Jimmy
    JOURNAL OF VIROLOGICAL METHODS, 2013, 188 (1-2) : 76 - 82
  • [38] Accuracy of the determination of S100 protein expression in malignant melanoma using a polyclonal antibody directed against S100 and monoclonal antibodies specific for S100 alpha and beta
    Shams, Farzad
    Spigler, Elzbieta
    Shams, Mohammad
    Birtchnell, Natalie
    Georgaki, Effrosyni
    Fernando, Patricia
    Nwokie, Theddeus
    Orchard, Guy Edward
    JOURNAL OF HISTOTECHNOLOGY, 2014, 37 (02) : 60 - 67