Accurate Quantification of Monoclonal Immunoglobulins Migrating in the Beta Region on Protein Electrophoresis

被引:3
|
作者
Omar, Nivin [1 ]
Madwani, Kiran [1 ]
Moideen, Pramila [1 ]
Manthei, David M. [2 ]
Keren, David F. [2 ]
Singh, Gurmukh [1 ]
机构
[1] Augusta Univ, Dept Pathol, Med Coll Georgia, Augusta, GA 30912 USA
[2] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
clinical pathology; clinical chemistry; immunology; immunopathology; monoclonal gammopathy; light chain-predominant multiple myeloma; FREE LIGHT-CHAIN; FOLLOW-UP; IMMUNOFIXATION; GAMMOPATHY; DIAGNOSIS; CRITERIA;
D O I
10.1093/labmed/lmab055
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background The concentration of monoclonal immunoglobulins (Igs) in neoplastic monoclonal gammopathic manifestations is generally measured by densitometric scanning of the monoclonal peaks on gel or by measuring absorbance at 210 nm in capillary electrophoresis (CE). For monoclonal Igs migrating in the beta region, measurement is complicated by the major beta-region proteins, namely, transferrin and C3. Methods C3 interference in densitometry was eliminated by heat treatment of serum, and monoclonal Igs were quantified by densitometry of the residual band. The immunochemical measurement of transferrin was converted to its equivalent densitometric quantity. For monoclonal Ig migrating with transferrin, the contribution of the latter was removed by subtracting the converted transferrin concentration from the combined densitometric quantification of the band. With CE, monoclonal Ig was measured by using immunosubtraction (ISUB) to guide demarcation. Results The results obtained using the C3 depletion and transferrin subtraction method were lower and yet comparable to the results derived from using CE measurement guided by ISUB. As we expected, the results from both methods were lower than those derived from a perpendicular drop measurement of the peak or via nephelometric assay of the involved isotype. Discussion Accurate measurement of monoclonal Igs is important for the diagnosis and monitoring of monoclonal gammopathic manifestations. Determination of serum free light chain concentration per gram of monoclonal Ig is an essential measure for the diagnosis of light chain-predominant multiple myeloma. The method described herein improves accuracy of measurements for monoclonal Igs migrating in the beta region, without the need for special reagents or equipment.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 38 条
  • [21] Monoclonal antibody therapeutics as potential interferences on protein electrophoresis and immunofixation
    Willrich, Maria Alice V.
    Ladwig, Paula M.
    Andreguetto, Bruna D.
    Barnidge, David R.
    Murray, David L.
    Katzmann, Jerry A.
    Snyder, Melissa R.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (06) : 1085 - 1093
  • [22] Urine Protein Immunofixation Electrophoresis: Free Light Chain Urine Immunofixation Electrophoresis Is More Sensitive than Conventional Assays for Detecting Monoclonal Light Chains and Could Serve as a Marker of Minimal Residual Disease
    Singh, Gurmukh
    Arinze, Nkechi
    Manthei, David M.
    Plapp, Frederick, V
    Bollag, Roni J.
    LABORATORY MEDICINE, 2023, 54 (05) : 527 - 533
  • [23] Detection of a monoclonal antibody therapy (ofatumumab) by serum protein and immunofixation electrophoresis
    Genzen, Jonathan R.
    Kawaguchi, Kathy R.
    Furman, Richard R.
    BRITISH JOURNAL OF HAEMATOLOGY, 2011, 155 (01) : 123 - 125
  • [24] Candidate recommendations for protein electrophoresis reporting from the Canadian Society of Clinical Chemists Monoclonal Gammopathy Working Group
    Booth, Ronald A.
    McCudden, Christopher R.
    Balion, Cynthia M.
    Blasutig, Ivan M.
    Bouhtiauy, Ihssan
    Rodriguez-Capote, Karina
    Catomeris, Peter
    Chan, Pak Cheung
    Chen, Yu
    Collier, Christine
    Hauff, Kristin
    Kalra, Jawahar
    Li, Dailin
    Lin, Dan C.
    Lou, Amy H.
    Meng, Qing H.
    Morrison, Tracy
    Pasic, Maria D.
    Qureshi, Mabood
    Randell, Ed
    Sohn, Kun-Young
    Thakur, Vinita
    Thomas, Dylan
    Thoni, Andrea
    Tomalty, Cheryl
    Yang, Liju
    Zamkanei, Mohebullah
    CLINICAL BIOCHEMISTRY, 2018, 51 : 10 - 20
  • [26] EVALUATION OF SERUM IMMUNOGLOBULINS BY PROTEIN ELECTROPHORESIS AND RATE NEPHELOMETRY BEFORE AND AFTER THERAPEUTIC PLASMA-EXCHANGE
    FILOMENA, CA
    FILOMENA, AP
    HUDOCK, J
    BALLAS, SK
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1992, 98 (02) : 243 - 248
  • [27] Method comparison for serum protein electrophoretic M-protein quantification: Agarose gel electrophoresis and capillary zone electrophoresis in canine and feline sera
    Jeffries, Christina M.
    Harris, R. Adam
    Ashton, Laura
    Moore, A. Russell
    VETERINARY CLINICAL PATHOLOGY, 2021, 50 (04) : 543 - 550
  • [28] Integrating Serum Protein Electrophoresis with Mass Spectrometry, A New Workflow for M-Protein Detection and Quantification
    Zajec, Marina
    Jacobs, Joannes F. M.
    Angelino, Corrie M. de Kat
    Dekker, Lennard J. M.
    Stingl, Christoph
    Luider, Theo M.
    De Rijke, Yolanda B.
    VanDuijn, Martijn M.
    JOURNAL OF PROTEOME RESEARCH, 2020, 19 (07) : 2845 - 2853
  • [29] Diagnostic accuracy of serum protein electrophoresis and free light chain measurements for monoclonal gammopathies
    Pena, Camila
    Ortiz, Manuela
    Voisin, Javier
    Peralta, Alexis
    Balboa, Viviana
    Delgado, Florencia
    REVISTA MEDICA DE CHILE, 2018, 146 (01) : 64 - 67
  • [30] Measurement of Monoclonal Immunoglobulin Protein Concentration in Serum Protein Electrophoresis: Comparison of Automated vs Manual/Human Readings
    Clavijo, Alex
    Ryan, Nathan
    Xu, Hongyan
    Singh, Gurmukh
    LABORATORY MEDICINE, 2020, 51 (03) : 252 - 258