A Feasibility Study on the Use of Optical Fibers for the Transfer of Scintillation Light to Silicon Photomultipliers

被引:5
|
作者
Hong, Seong Jong [1 ]
Kim, Chan Mi [1 ]
Cho, Sung Mook [1 ]
Woo, Heon [1 ]
Ko, Guen Bae [2 ]
Kwon, Sun Il [3 ]
Rhee, June Tak [4 ]
Song, In Chan [5 ]
Lee, Jae Sung [6 ,7 ,8 ]
机构
[1] Eulji Univ, Dept Radiol Sci, Songnam 461731, South Korea
[2] Seoul Natl Univ, Dept Nucl Med, Coll Med, Seoul 110744, South Korea
[3] Seoul Natl Univ, Interdisciplinary Programs Radiat Appl Life Sci M, Coll Med, Seoul 110744, South Korea
[4] Konkuk Univ, Dept Phys, Seoul 143701, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[6] Med Res Ctr, Dept Nucl Med, Inst Radiat Med, Seoul 110744, South Korea
[7] Med Res Ctr, Dept Biomed Sci, Inst Radiat Med, Seoul 110744, South Korea
[8] Med Res Ctr, Dept WCU Brain & Cognit Sci, Inst Radiat Med, Seoul 110744, South Korea
基金
新加坡国家研究基金会;
关键词
GEANT4 Monte-Carlo simulation; integrated PET/MRI; optical fiber; silicon photomultipliers (SiPM); SOLID-STATE PHOTOMULTIPLIERS; SIMULTANEOUS PET; MRI; DETECTOR; LSO;
D O I
10.1109/TNS.2011.2112778
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Integrated PET/MRI units with simultaneous acquisition capability are set to play an important role in studies of human breast and prostate imaging and brain function. However, to take advantage of existing MRI units in hospitals and institutions, minimally modified combined PET MRI is highly desirable. In addition, the current MRI trend is to utilize powerful body coils to transmit radio-frequency (RF) waves and local RF coils to receive signals. The authors propose a silicon photomultiplier (SiPM) PET equipped with optical fiber bundles that transfer photons from scintillation crystal to SiPM. To investigate the feasibility of SiPM PET using optical fiber bundles, the authors studied the performances of SiPM/scintillator couplings using single optical fibers and a fiber bundle. GEANT4 Monte-Carlo simulation was used to study scintillation photon transfer from scintillation crystals to the SiPM. This simulation showed that light loss, due to the bending of an optical fiber, is not significant for a fiber with a diameter of 2.0 mm and a bending radius of greater than 25 mm. To validate the GEANT4 Monte-Carlo simulation, several simple detectors were assembled and tested. Simulation results agreed reasonably well with experimental results. Two Hamamatsu multi-pixel photon counters (MPPCs) were tested using double clad optical fibers of 1.5 mm and 2.0 mm diameter, and 25 mm and 50 mm bending radius, respectively. When two MPPCs were directly attached to 2.0 2.0 10.0 mm(3) LYSO crystals, a similar to 14% energy and a similar to 1.3 ns coincidence timing resolution were obtained at full width half maximum (FWHM). With one of the MPPCs attached to an optical fiber of 1.5 mm diameter, 50 mm bending radius, and length 300 mm, energy and coincidence timing resolutions were 27% and 2.2 ns, respectively. With an optical fiber bundle made of bare fibers with 1.5 mm diameter and length 100 mm, an similar to 26% energy resolution was obtained. Even though the Monte-Carlo simulation showed light loss was not significant for a single 90 degrees turn of bending, the mechanical integrity of the optical fiber, especially the absence of cracks which can be caused by sharp bending, seemed to be a far more important constraint on sharp bending. These initial results are encouraging with respect to the use of combined SiPM PET using optical fibers.
引用
收藏
页码:579 / 589
页数:11
相关论文
共 50 条
  • [1] Time-domain diffuse optical tomography using silicon photomultipliers: feasibility study
    Di Sieno, Laura
    Zouaoui, Judy
    Herve, Lionel
    Pifferi, Antonio
    Farina, Andrea
    Martinenghi, Edoardo
    Derouard, Jacques
    Dinten, Jean-Marc
    Mora, Alberto Dalla
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (11)
  • [2] VUV-Sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
    Jamil, A.
    Ziegler, T.
    Hufschmidt, P.
    Li, G.
    Lupin-Jimenez, L.
    Michel, T.
    Ostrovskiy, I
    Retiere, F.
    Schneider, J.
    Wagenpfeil, M.
    Alamre, A.
    Albert, J. B.
    Anton, G.
    Arnquist, I. J.
    Badhrees, I
    Barbeau, P. S.
    Beck, D.
    Belov, V
    Bhatta, T.
    Bourque, E.
    Brodsky, J. P.
    Brown, E.
    Brunner, T.
    Burenkov, A.
    Cao, G. F.
    Cao, L.
    Cen, W. R.
    Chambers, C.
    Charlebois, S. A.
    Chiu, M.
    Cleveland, B.
    Coon, M.
    Cote, M.
    Craycraft, A.
    Cree, W.
    Dalmasson, J.
    Daniels, T.
    Darroch, L.
    Daugherty, S. J.
    Daughhetee, J.
    Delaquis, S.
    Mesrobian-Kabakian, A. Der
    DeVoe, R.
    Dilling, J.
    Ding, Y. Y.
    Dolinski, M. J.
    Dragone, A.
    Echevers, J.
    Fabris, L.
    Fairbank, D.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (11) : 2823 - 2833
  • [3] Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study
    Ciarrocchi E.
    Belcari N.
    Guerra A.D.
    Cherry S.R.
    Lehnert A.
    J. Hunter W.C.
    McDougald W.
    Miyaoka R.S.
    Kinahan P.E.
    EJNMMI Physics, 2 (1) : 1 - 22
  • [4] Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers
    Artikov, Akram
    Baranov, Vladimir
    Blazey, Gerald C.
    Chen, Ningshun
    Chokheli, Davit
    Davydov, Yuri
    Dukes, E. Craig
    Dychkant, Alexsander
    Ehrlich, Ralf
    Francis, Kurt
    Frank, M. J.
    Glagolev, Vladimir
    Hansen, Sten
    Magill, Stephen
    Oksuzian, Yuri
    Pla-Dalmau, Anna
    Rubinov, Paul
    Simonenko, Aleksandr
    Song, Enhao
    Stetzler, Steven
    Wu, Yongyi
    Uzunyan, Sergey
    Zutshi, Vishnu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 890 : 84 - 95
  • [5] Study of silicon photomultipliers for use in neutron decay experiments
    Dubbers, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1009
  • [6] Improving the light collection efficiency of silicon photomultipliers through the use of metalenses
    Villalpando, A. A. Loya
    Martin-Albo, J.
    Chen, W. T.
    Guenette, R.
    Lego, C.
    Park, J. S.
    Capasso, F.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (11)
  • [7] Pulse shape study of the fast scintillation light emitted from xenon-doped liquid argon using silicon photomultipliers
    Galbiati, C.
    Li, X.
    Luo, J.
    Marlow, D. R.
    Wang, H.
    Wang, Y.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (02)
  • [8] Studies of Optical Mixers for use with Silicon Photomultipliers to Ameliorate Signal Saturation
    Baumbaugh, B.
    Broughton, C.
    Burke, C.
    Ciastko, L.
    Conti, J.
    Daily, K.
    Dolezal, B.
    Heering, A.
    Karmgard, D.
    Marchant, J.
    Mckenna, M.
    O'Brien, M.
    Rose, P.
    Sharkey, S.
    Taylor, J.
    Tripepi, M.
    Ruchti, R.
    Vigneault, M.
    Wayne, M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 446 - 449
  • [9] A FEASIBILITY STUDY ON THE USE OF AMORPHOUS-SILICON AS OPTICAL-RECORDING MEDIUM
    LEE, MC
    TSENG, CJ
    HUANG, CR
    HUANG, TH
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 (02): : 193 - 196
  • [10] Vacuum ultra-violet and ultra-violet scintillation light detection by means of silicon photomultipliers at cryogenic temperature
    Falcone, A.
    Bertoni, R.
    Boffelli, F.
    Bonesini, M.
    Cervi, T.
    Menegolli, A.
    Montanari, C.
    Prata, M. C.
    Rappoldi, A.
    Raselli, G. L.
    Rossella, M.
    Simonetta, M.
    Spanu, M.
    Torti, M.
    Zani, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 216 - 219